User manual CASIO E-CON

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CASIO E-CON. We hope that this CASIO E-CON user guide will be useful to you.

Lastmanuals help download the user guide CASIO E-CON.


Mode d'emploi CASIO E-CON
Download
Manual abstract: user guide CASIO E-CON

Detailed instructions for use are in the User's Guide.

[. . . ] 1. 20 Software for the ALGEBRA FX 2. 0 Series 1. E-CON Overview EA-100 Setup Setup Memory Program Converter Starting a Sampling Operation All of the explanations provided here assume that you are already familiar with the operating precautions, terminology, and operational procedures of the calculator and the EA-100. 1-1 E-CON Overview 1. E-CON Overview · From the Main Menu, select E-CON to enter the E-CON Mode. · The E-CON provides the functions listed below for simple and more efficient data sampling using the CASIO EA-100. Displays a screen for setting up the EA-100. [. . . ] S-G Smoothing b(5-p): 5-point d(17-p): 17-point · 3(MED) . . . . . . . Median Filter b(3-p): 3-point c(5-p): 5-point · Note that the above options appear only when real-time sampling is turned off (by pressing 2(NO) for the Real-Time item). After all the settings are the way you want, press w to return to the Advanced Setup menu. c(9-p): 9-point e(25-p): 25-point u To configure a custom probe You can use the procedures in this section to configure a custom probe*1 for use with the EA-100. Creating a New Custom Probe Configuration To configure a custom probe, you must input values for the constants of the fixed linear transformation formula (ax + b). The required constants are slope (a) and intercept (b). x in the above expression (ax + b) is the sampled voltage value (sampling range: 0 to 5 volts). You can use either of the two following procedures to create a new custom probe configuration while creating an EA-100 setup using Advanced Setup. *1 The term "custom probe" means any sensor other than the CASIO or VERNIER sensors specified as standard for the E-CON Mode. 2-12 EA-100 Setup · To configure a custom probe starting from the Advanced Setup menu 1. From the E-CON main menu, press 1(SETUP) and then c(Advan) to display the Advanced Setup menu. · See "Creating an EA-100 Setup Using Advanced Setup" on page 2-4 for more information. On the Advanced Setup menu, press f(Custom Probe) to display the Custom Probe List. · The message "No Custom Probe" appears if the Custom Probe List is empty. · This displays the screen for inputting the name of the new custom probe. Input up to 18 characters for the custom probe name, and then press w. · This displays the screen for configuring a new custom probe. 5. Use the function key operations described below to make custom probe configuration settings. · To change the setting of an item, first use the f and c cursor keys to move the highlighting to the item. Next, use the function keys to select the setting you want. (1) Slope Press 1(EDIT) to display a dialog box for inputting the slope for the linear transformation formula. (2) Intercept Press 1(EDIT) to display a dialog box for inputting the intercept for the linear transformation formula. (3) Unit Name Press 1(EDIT) to display a dialog box for inputting up to eight characters for the unit name. Press wand then input a memory number (1 to 99). · This advances to the Channel parameter setting screen in step 1 under "To change Channel parameter settings" on page 2-6. From there you can continue with the EA-100 Advanced Setup procedure. 2-13 EA-100 Setup · To configure a custom probe starting from the Channel parameter setting screen 1. [. . . ] · The message "Complete!" appears when conversion is complete. # When you convent setup data to a CFX-9850 Series or fx-7400 Series program, any sample value storage list number greater than 5 is changed to 5. # CFX-9850 Series or fx-7400 Series calculators support up to six lists only. # List 6 is used for EA-100 setup. 5-1 Starting a Sampling Operation 5. Starting a Sampling Operation The section describes how to use a setup created using the E-CON Mode to start an EA-100 sampling operation. k Before getting started. . . Be sure to perform the following steps before starting sampling with the EA-100. In accordance with the setup you plan to use, connect the proper sensor to the appropriate EA-100 channel. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CASIO E-CON

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CASIO E-CON will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag