User manual CASIO FX115-MS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CASIO FX115-MS. We hope that this CASIO FX115-MS user guide will be useful to you.

Lastmanuals help download the user guide CASIO FX115-MS.


Mode d'emploi CASIO FX115-MS
Download
Manual abstract: user guide CASIO FX115-MS

Detailed instructions for use are in the User's Guide.

[. . . ] 7 kAbsolute Value and Argument Calculation . . . . . . . . . . . . . 8 kRectangular Form Polar Form Display . . . . . . . . . . . . . . 8 kConjugate of a Complex Number . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Base-n Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (Result: A = 16. 8) B AC ­ 1 DC 2 2 (B?) (A?) (C?) (D?) (A?) p2pup1-pk, R1\2T-ph-pkK AI 14 = ] 2= 9l8= [[ AI · The SOLVE function finds approximations based on Newton's method, which means that error can occur. Certain expressions or initial values may result in error without convergence of results. · If an expression does not include an equals sign (=), the SOLVE function produces a solution for expression = 0. Scientific Function Calculations COMP Use the F key to enter the COMP Mode when you want to perform basic arithmetic calculations. COMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 1 k Inputting Engineering Symbols COMP EQN CMPLX · Turning on engineering symbols makes it possible for you to use engineering symbols inside your calculations. E-5 · To turn engineering symbols on and off, press the F key a number of times until you reach the setup screen shown below. Disp 1 · Press 1. On the engineering symbol setting screen that appears, press the number key ( 1 or 2) that corresponds to the setting you want to use. 1(Eng ON): Engineering symbols on (indicated by "Eng" on the display) 2(Eng OFF): Engineering symbols off (no "Eng" indicator) · The following are the nine symbols that can be used when engineering symbols are turned on. To input this symbol: Perform this key operation: Ak k (kilo) M (Mega) AM G (Giga) Ag T (Tera) At m (milli) Am µ (micro) AN n (nano) An p (pico) Ap f (femto) Af Unit 103 106 109 1012 10­3 10­6 10­9 10­12 10­15 · For displayed values, the calculator selects the engineering symbol that makes the numeric part of the value fall within the range of 1 to 1000. · Engineering symbols cannot be used when inputting fractions. · Example: 9 Ö10 = 0. 9 m (milli) Eng F . . . . . 1(Disp) 1 9 \ 10 = 9 1 0. m 900. When engineering symbols are turned on, even standard (non-engineering) calculation results are displayed using engineering symbols. E-6 AP J 9 1 0. 9 m 900. Complex Number Calculations CMPLX Use the F key to enter the CMPLX Mode when you want to perform calculations that include complex numbers. CMPLX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 2 · The current angle unit setting (Deg, Rad, Gra) affects CMPLX Mode calculations. You can store an expression in CALC memory while in the CMPLX Mode. · Note that you can use variables A, B, C, and M only in the CMPLX Mode. Variables D, E, F, X, and Y are used by the calculator, which frequently changes their values. You should not use these variables in your expressions. · The indicator "RI" in the upper right corner of a calculation result display indicates a complex number result. Press A r to toggle the display between the real part and imaginary part of the result. · You can use the replay function in the CMPLX Mode. Since complex numbers are stored in replay memory in the CMPLX Mode, however, more memory than normal is used up. · Example: (2 3i) (4 5i) (Real part 6) (Imaginary part 8 i) 6 8i 2+3i+4+5i= Ar E-7 k Absolute Value and Argument Calculation Supposing the imaginary number expressed by the rectangular form z = a + bi is represented as a point in the Gaussian plane, you can determine the absolute value (r) and argument ( ) of the complex number. [. . . ] 4 Load a new battery into the unit with its positive k and negative l ends facing correctly. 5 Replace the back cover and secure it in place with the six screws. 6 Press 5 to turn power on. Screw Auto Power Off Calculator power automatically turns off if you do not perform any operation for about six minutes. When this happens, press 5 to turn power back on. E-15 Specifications Power Supply: fx-100MS: Single AA-size battery (R6P(SUM-3)) fx-115MS: Solar cell and a single G13 Type button battery (LR44) Battery Life: fx-100MS: Approximately 17, 000 hours continuous display of flashing cursor. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CASIO FX115-MS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CASIO FX115-MS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag