User manual CAT EYE CC-7000 (VECTRA)

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CAT EYE CC-7000 (VECTRA). We hope that this CAT EYE CC-7000 (VECTRA) user guide will be useful to you.

Lastmanuals help download the user guide CAT EYE CC-7000 (VECTRA).


Mode d'emploi CAT EYE CC-7000 (VECTRA)
Download
Manual abstract: user guide CAT EYE CC-7000 (VECTRA)

Detailed instructions for use are in the User's Guide.

[. . . ] · Do not disassemble the computer. · Clean the computer and accessories with a soft cloth dampened with a neutral detergent. Do not use thinners, benzene, or alcohol on the computer. Troubleshooting No display. Replace it, and re-enter the correct information. [. . . ] (All Clear a ). Standard Parts #169-6590 Parts Kit ENG Wireless Sensor The sensor was designed to receive signals within a limited range to prevent sensor signal interference. Thus, the sensor and computer must be relatively close. If the temperature or battery power is low, they may need to be even closer than normal. The sensor must be installed at the top of the fork, and the distance between the sensor and the computer should not exceed approximately 70 cm. Install the computer on the stem, with its bottom surface facing the sensor. (Take into account the angle of the stem. ) Interference may occur, resulting in malfunction, if the computer is: · Near a TV, PC, radio, motor, or in a car or train. · Close to a railroad crossing, railway tracks, TV stations and or radar base. · Close to a second bicycle with wireless sensors. #169-6580 Speed Sensor A #169-6570 Bracket kit Correct installation of sensor and magnet A Attach the magnet 3 so that it passes through the sensor zone of the sensor 2. B Be sure to have a 5 mm-or-less clearance between the sensor 2 and magnet 3. Replacing the Battery · Computer If the Wheel Size icon ( or ) flashes, replace the battery. The Total Distance can be entered manually. Before removing the battery, note the current Total Distance. During measurement, the speed unit icon flashes. The maximum speed and total distance will update, regardless of measurement. · Auto-mode (automatic measurement) If the icon is visible, measurement is automatic. In Auto-mode, starting/stopping measurement using the START/ STOP button is impossible. · Manual measurement If the icon does not light, starting/stopping the measurement using the START/STOP button is possible. * Use the menu screen to toggle between Auto-mode ON and OFF. For further information, see the MENU FLOW. #169-9690 Hi-Power Wheel Magnet LIMITED WARRANTY - 2-Year Computer/Sensor only (Accessories/Attachments and Battery Consumption excluded) If trouble occurs during normal use, the part of the Main Unit or sensor will be repaired or replaced free of charge. The service must be performed by CatEye Co. , Ltd. To return the product, pack it carefully and remember to enclose the warranty certificate with instruction for repair. Please write or type your name and address clearly on the warranty certificate. Insurance, handling and transportation charges to our service shall be borne by person desiring service. Switching Mode symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 115 Boulder, CO 80302 Phone: 303. 443. 4595 Toll Free: 800. 5CATEYE Fax: 303. 473. 0006 E-mail: service@cateye. com URL: http://www. cateye. com Power-saving function If the computer has not received a signal for 10 minutes, powersaving mode will activate and only the clock will be displayed. When the computer receives a sensor signal again, the measuring screen reappears. If two weeks' inactivity elapses, power-saving mode will change to SLEEP mode. Pressing the MODE or START/STOP button in SLEEP mode brings up the measuring screen. Dual Wheel Size Two wheel sizes (Wheel sizes and ) can be registered on the computer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CAT EYE CC-7000 (VECTRA)

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CAT EYE CC-7000 (VECTRA) will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag