User manual CHAMBERLAIN LA412

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN LA412. We hope that this CHAMBERLAIN LA412 user guide will be useful to you.

Lastmanuals help download the user guide CHAMBERLAIN LA412.


Mode d'emploi CHAMBERLAIN LA412
Download
Manual abstract: user guide CHAMBERLAIN LA412

Detailed instructions for use are in the User's Guide.

[. . . ] LA412 & LA412-S 12 VOLT DC SINGLE SOLAR RESIDENTIAL GATE OPERATOR OW N E R ' S M A N U A L FOR RESIDENTIAL USE ONLY Please read this manual and the enclosed safety materials carefully!Periodic checks of the operator by a qualified technician are required to ensure safe operation. The model number is located inside the control box of your operator. Serial # Installation date 2 YEAR WARRANTY SAFETY TABLE OF CONTENTS Safety Symbol and Signal Word Review Safety Installation Information Gate Construction Information Important Safety Information 1-5 SOLAR PANEL INSTALLATION 1 2 3 4-5 25-28 29-32 29-31 32 32 ADJUSTMENT Limits Force Adjustment Timer-to-Close INTRODUCTION Operator Specifications Carton Inventory Hardware Inventory Additional Items for Purchase Tools Needed 6-7 6 6 7 7 7 PROGRAMMING Remote Controls Keyless Entry Erase All Codes Test 33 33 33 33 33 INSTALLATION Overview of Typical Installation Check Your Gate Mounting Options Manual Release Determine the Position of the Pull-to-Open Bracket Determine the Position of the "Optional" Push-to-Open Bracket Assemble Gate Post Bracket (Pull-to-Open) Attach Brackets to Gate Operator Determine Mounting Location Measuring and Marking for the Gate Bracket Position Gate Operator on Gate Test Gate Travel Secure Post Bracket to Gate Post Secure Gate Bracket to Gate Warning Sign Placement Standard Control Box Large Metal Control Box (XLM) 8-19 8-9 10 10 11 11 11 12 12 13 13 14 15 15 16 16 17-18 19 OPERATION AND MAINTENANCE Reset Button Remote Control Sleep Mode Manual Release Maintenance 34-35 34 34 34 35 35 TROUBLESHOOTING Wiring Diagram Diagnostic Chart Troubleshooting Chart 36-39 36 37 38-39 REPAIR PARTS WIRING Connect the Gate Operator (Gate 1) to the Control Box 20 Set the Lock/Bipart Delay (Model LA412-S Only) 21 Connect the Gate Operator (Gate 2) to the Control Box (Model LA412-S Only) 22 Junction Box (Model LA412-S Only) 23-24 20-24 Control Box Gate Operator Arm How to Order Repair Parts 40-41 40 40 41 WARRANTY POLICY ACCESSORIES TEMPLATE 41 42 BACK COVER SAFETY » SAFETY SYMBOL AND SIGNAL WORD REVIEW When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. [. . . ] 29 ADJUSTMENT » LIMITS LIMITS NOTES: · The gate with the longer travel span (opening) must be set as the primary gate (GATE 1). · If one gate is overlapping the other, the gate that is overlapping must be connected to GATE 1 so it will start moving before the other gate; GATE 2 may need to be closed first if there is overlap or a gate lock is being used. · The programming can be exited at any time by pressing the RESET button. Programming times-out automatically after 60 seconds of inactivity. DUAL GATE (LEFT-SIDE PRIMARY OPERATOR) 1 Close the gate. 2 Engage the operator by turning the release lever clockwise 180°, then turning the key clockwise 180°. PROGRAM OPEN the LEARN 3 Presswill blink). LIMITS button (SET OPEN LIMIT LED LEARN LIMITS button R2 K2 U4 SET OPEN LIMIT D4 D2 RESET BUTTON 1 4 Press the GATEopen right button to the left operator. DIAGNOSTIC GATE 1 5 SET CLOSE Press the GATE 2 right button to move the right operator into the OPEN position. SET CLOSE LIMIT LE LIMIT GATE 2 6 Press the LEARN LIMITS button. Control board will beep. SET OPEN LIMIT SET CLOSE LIMIT FORCE PROGRAM CLOSE 7 When the SET CLOSE LIMITS LED blinks, press the GATE 2 left button to close the right operator. SET CLOSE LIMIT LE LIMITS GATE 2 FORCE 8 GATE 1to left button Press the DIAGNOSTIC GATE 1 9 Press the LEARN LIMITS button. SET OPEN LIMIT SET CLOSE LIMIT close the left operator. SET CLOSE The control board beeps and the SET OPEN LIMIT and SET CLOSE LIMIT LEDs stop blinking, programming is now complete. (If the SET OPEN LIMIT LED continues to blink, repeat programming. If the problem continues, see Troubleshooting section. ) Test the limits by pressing the SBC to open and close the gate. 30 ADJUSTMENT » LIMITS LIMITS NOTES: · The gate with the longer travel span (opening) must be set as the primary gate (GATE 1). · If one gate is overlapping the other, the gate that is overlapping must be connected to GATE 1 so it will start moving before the other gate; GATE 2 may need to be closed first if there is overlap or a gate lock is being used. · The programming can be exited at any time by pressing the RESET button. Programming times-out automatically after 60 seconds of inactivity. DUAL GATE (RIGHT-SIDE PRIMARY OPERATOR) 1 Close the gate. 2 Engage the operator by turning the release lever clockwise 180°, then turning the key clockwise 180°. PROGRAM OPEN the LEARN 3 Presswill blink). LIMITS button (SET OPEN LIMIT LED LEARN LIMITS button R2 K2 U4 SET OPEN LIMIT D4 D2 RESET BUTTON 4 Press the GATE 1 left button to open the right operator. DIAGNOSTIC GATE 1 5 SET CLOSE Press the GATE 2 left button to move the left operator into the OPEN position. SET CLOSE LIMIT LE LIMIT GATE 2 6 FORCE Press the LEARN LIMITS button. Control board will beep. SET OPEN LIMIT SET CLOSE LIMIT PROGRAM CLOSE the LIMITS 7 Whenblinks, SET CLOSEGATE 2 LED press the right button to close the left operator. SET CLOSE LIMIT LE LIMITS GATE 2 the GATE 1 8 Press button to close right the right operator. DIAGNOSTIC GATE 1 9 Press theLIMITS LEARN button. SET OPEN LIMIT SET CLOSE LIMIT FORCE SET CLOSE The control board beeps and the SET OPEN LIMIT and SET CLOSE LIMIT LEDs stop blinking, programming is now complete. (If the SET OPEN LIMIT LED continues to blink, repeat programming. If the problem continues, see Troubleshooting section. ) Test the limits by pressing the SBC to open and close the gate. 31 ADJUSTMENT » FORCE ADJUSTMENT + TIMER-TO-CLOSE (TTC) Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing gate. · Too much force on gate will interfere with proper operation of safety reversal system. · NEVER increase force beyond minimum amount required to close gate. · NEVER use force adjustments to compensate for a binding or sticking gate. · If one control (force or travel limits) is adjusted, the other control may also need adjustment. [. . . ] Failure to comply strictly with those instructions will void this limited warranty in its entirety. If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806, toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN LA412

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN LA412 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag