User manual CHAMBERLAIN SL575

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHAMBERLAIN SL575. We hope that this CHAMBERLAIN SL575 user guide will be useful to you.

Lastmanuals help download the user guide CHAMBERLAIN SL575.


Mode d'emploi CHAMBERLAIN SL575
Download
Manual abstract: user guide CHAMBERLAIN SL575

Detailed instructions for use are in the User's Guide.

[. . . ] GL CO NT RO LL ER BO AR D HEAVY DUTY SLIDE GATE OPERATOR 2 YEAR WARRANTY Serial # ________________________ (located on electrical box cover) Installation Date__________________ MODEL SL575 IS FOR VEHICULAR PASSAGE GATES ONLY AND IS NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE MODEL SL575 TABLE OF CONTENTS OPERATOR SPECIFICATIONS Carton Inventory . 2 Operator Dimensions & Horsepower Chart . 4 · These instructions are intended to highlight certain safety related issues. These instructions are not intended to be comprehensive. [. . . ] Then follow the steps above to reprogram each remote control. FIGURE 2 CONSTANT Jumper OPERATION Output Duration Terminals MOMENTARY Jumper OPERATION Output Duration Terminals FIGURE 3 OPENING RECEIVER OPEN RECEIVER Connect Antenna Indicator Light Learn Button M C P2 M Output Duration Terminals Security Mode Power Supply Jumper 24V 12V NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or remote control are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 1 234 5 NORM HIGH 6 7 8 9 10 11 12 13 14 ACCESSORY WIRING Terminals 6 & 5 (Com) - Soft Open These terminals are intended for use as a general open control. Accessories that may be wired to this input include: Telephone Entry Systems, Radio Receiver (Commercial Applications), Exit Loop Detector, Keypads, 7-Day Timer. NOTE: Will not override a double entrapment (signalled by the gate stopped and entrapment alarm on). REMOTELY MOUNTED STOP/RESET CONTROL WIRING · This control will function as a Stop/Reset command and is to be wired within line of sight of the gate. · Wire Stop/Reset control station to terminals 3 and 5 on the control box on the operator. Make sure that all Stop/Reset controls are wired in series. 123 56 789 0# Soft Open 1 234567 Control Conduit Control Conduit 1 2 3 Stop/Reset Button Stop/Reset Button 19 M ACCESSORY WIRING (CONTINUED) Terminals 7 & 5 (Com) - Hard Open Override Control Input These terminals are intended for use only with the open control of a 3-button station that is installed within line of sight of the gate. A momentary activation of this input will cause the gate to open. Activation of this input for longer than three seconds will enable the control to be used as a constant pressure override device. This will allow the user, in emergencies, to override a failed accessory such as a loop detector or photo-eye. Terminals 4 & 5 (Com) - Close Override Control Input These terminals are intended for use only with the close control of a 3-button station that is installed within line of sight of the gate. A momentary activation of this input will cause the gate to close. Activation of this input for longer than three seconds will enable the control to be used as a constant pressure override device. This will allow the user, in emergencies, to override a failed accessory such as a loop detector or photo-eye. Terminals 8 & 5 (Com) - Interrupt (Safety) Loop Input These terminals are intended for use with a loop detector. This input functions to reverse a closing gate to the open limit. Latching this input will reset the timer to close. Terminals 2 & 5 (Com) - Shadow Loop Input These terminals are intended for use with a loop detector and is primarily used on swing gate operators. This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active. The control board senses commands using +24Vdc from terminal #3. Commands are seen when +24Vdc is applied to the controller's input terminals. [. . . ] Clutch shaft kit Complete with: Clutch shaft, sprockets, e-ring, compression spring, pulley, washer, bearings, retaining ring, disconnect splined hub and roll pin. NOT SHOWN Roller Chain (Sprocket Reduction) Antenna K2 K75-34824 K3 K75-34828 K4 K5 K6 K7 K75-34842 K29-32410 K75-19977 K72-34844 10 23-3001 23-3005 K8 K72-34845 01-34851 01-34851SP 01-34851FR 19-48047M K1C3196-3 34 ILLUSTRATED PARTS 5 9 8 K4 (K75-34842) 3 7 K6 (K75-19977) 10 4 K7 (K72-34844) K3 (K75-34828) K2 (K75-34824) K8 (K72-34845) K5 (K29-32410) 1 2 6 K1 (71-B120) (71-B240) (71-B575) K3 (K75-34828) 35 ELECTRICAL BOX 5 3 4 7 1 3 9 2 K1 (K72-34818) 6 8 INDIVIDUAL PARTS ITEM 1 2 3 4 5 6 7 PART # K001A5566 312HM 13-10024 23-10041 03-8024-K 23-34822 21-3260-1 21-10298-1 23-30716 25-2006 25-2008 DESCRIPTION Control board Radio - 315 MHz Limit nut Limit switch Contactor Open/close switch Transformer -115/208/230/460Vac/60VA Transformer - 575Vac/100VA Stop switch VARIABLE PARTS Overload - 6 AMP - SL575-50-21, SL575-50-81 Overload - 8 AMP - SL575-75-21, SL575-75-81, SL575-100-21, SL575-100-81 Overload - 10 AMP - SL575-50-11 Overload - 15 AMP - SL575-100-11 Overload - 1. 8 to 2. 6 AMP SL575-100-53 (NOT SHOWN) RPM Sensor (Hall effect) 36 ITEM K1 PART # K72-34818 SERVICE KITS DESCRIPTION Limit shaft kit Complete with: Limit shaft, limit nuts, limit bearings, limit sprocket, shim washers, compression ring, roll pin and e-ring. *To order a complete replacement electrical box kit contact technical support at 1-800-528-2806. 8 9 25-2010 25-2015 25-4002-SK K74-18379 *Non stocked item. Please allow additional delivery time. NOTES 37 NOTES 38 NOTES 39 WARRANTY POLICY AND SERVICE LIFTMASTER® TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. warrants to the final purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAMBERLAIN SL575

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAMBERLAIN SL575 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag