User manual CHICAGO 99722

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CHICAGO 99722. We hope that this CHICAGO 99722 user guide will be useful to you.

Lastmanuals help download the user guide CHICAGO 99722.


Mode d'emploi CHICAGO 99722
Download
Manual abstract: user guide CHICAGO 99722

Detailed instructions for use are in the User's Guide.

[. . . ] Safety Precautions and Warnings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. 1 On-Board Diagnostics (OBD) II. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. 2 Diagnostic Trouble Codes (DTCs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] When DTC definition covers more than one screen, use LEFT/RIHT button to view additional information on previous/next screens. For manufacturer specific codes, you need to select a vehicle make on an additional screen to look for DTC definitions. If definition could not be found (SAE or Manufacturer Specific), the scan tool displays "DTC definition not found!4) To view next or previous DTC in the built-in DTC library, use UP/DOWN button. 12 5) To enter another DTC, press ESC button to return to previous screen. 6) To exit to Main Menu, press ESC button. 3. 8 Product Setup The scan tool allows you to make the following adjustments and settings: 1) Language: Selects desired language. 2) Contrast adjustment: Adjusts the contrast of the LCD display. 3) Unit of measure: Sets the unit of measure to English or Metric. 4) Auto Power-off: Sets automatic power-off time limits. 6) Tool self-test: Tests the LCD display and the keyboard. · Settings of the unit will remain until change to the existing settings is made. To enter the setup menu mode From the keyboard: Press ESC button to enter System Setup menu. Follow instructions to make adjustments and settings as described in the following setup options. System Setup Language Contrast Unit of Measure Auto Power-off Beep Set Tool Self-test 1/6 ? From Main Menu: Use UP/DOWN scroll button to select System Setup, and press ENTER button. Follow instructions to make adjustments and settings as described in the following setup options. 13 Main Menu Diagnostics DTC Lookup Review Data System Setup Tool Information 4/5 ? Language Setup · English is the default language. 1) From System Setup menu, use UP/DOWN scroll button to select Language, and press ENTER button. System Setup Language Contrast Unit of Measure Auto Power-off Beep Set Tool Self-test 1/6 ? 2) Use UP/DOWN scroll button to select the desired language and press ENTER button to save your selection and return to previous menu. Language 1/3 English Français Español 14 Contrast Adjustment 1) From System Setup menu, use UP/DOWN scroll button to select Contrast, and press ENTER button. System Setup Language Contrast Unit of Measure Auto Power-off Beep Set Tool Self-test 2/6 ? 2) From Contrast menu, use UP/DOWN scroll button to increase or decrease contrast. Contrast 30% Use or to change 3) Press ENTER button to save your settings and return to previous menu. Unit of Measurement · Metric is the default measurement unit. 1) From System Setup menu, use UP/DOWN scroll button to select Unit of Measure and press ENTER button. 15 System Setup Language Contrast Unit of Measure Auto Power-off Beep Set Tool Self-test 3/6 ? 2) From Unit of Measure menu, use UP/DOWN scroll button to select the desired unit of measurement. Unit of Measure English Metric 2/2 ? 3) Press ENTER button to save your selection and return to previous menu. Auto Power-off · The minimum automatic power-off time is 1 minute, and the maximum is 20 minutes. · Automatic power-off setup function can be available only when the scanner is powered by cell battery. 1) From System Setup menu, use UP/DOWN scroll button to select Auto Power-off and press ENTER button. 16 System Setup Language Contrast Unit of Measure Auto Power-off Beep Set Tool Self-test 4/6 ? 2) From Auto Power-off menu, use UP/DOWN scroll button to increase or decrease time. Auto Power-off 01 Minute [ ] ­ Increase time [ ] ­ Decrease time [ENTER] - Confirm 3) Press ENTER button to save your setting and return to previous menu. Beep Set · The default setting is Beep On. 1) From System Setup menu, use UP/DOWN scroll button to select Beep Set and press ENTER button. System Setup Language Contrast Unit of Measure Auto Power-off Beep Set Tool Self-test 5/6 ? 17 2) From Beep Set menu, use UP/DOWN scroll button to select Beep ON or Beep OFF to turn on/off the beep. Beep Set 2/2 Beep ON Beep OFF ? 3) Press ENTER button to save your selection and return to previous menu. Tool Self-test The Tool Self-test function checks if the display and keyboard are working properly. Display test The Display Test function checks if the LCD display is working normally. 1) From System Setup menu, use UP/DOWN scroll button to select Tool Self-Test, and press ENTER button. System Setup Language Contrast Unit of Measure Auto Power-off Beep Set Tool Self-test 6/6 ? 2) Select Display Test from Tool Self-Test menu and press ENTER button. 18 Tool Self-test Display Test Keyboard Test 1/2 ? 3) 4) Press ENTER button again to start test. Look for missing spots in the solid black characters. When completed, press ESC button to return. B. Keyboard Test The Keyboard Test function verifies if the keys are working properly. 1) Use UP/DOWN scroll button to select Keyboard Test from Tool Self-test menu, and then press ENTER button. Tool Self-test Display Test Keyboard Test 2/2 ? 2) Press any key to start test. [. . . ] Unit of Measure 2) Wait a few seconds while the scan tool validates the PID MAP. 32 . . . . . . . . . . . . . . . . . I/M Readiness Reading PID. . . - Please Wait - . . . 3) If the vehicle supports both types of tests, then both types will be shown on the screen for selection. . . . . . . . . . . . . . . . I/M Readiness. . . . . . . . . . . . . . . . . . . 1/2 Since DTCs Cleared This Drive Cycle ? 4) Use UP/DOWN scroll button, as necessary, to view the status of the MIL light ("ON" or "OFF) and the following monitors: Misfire monitor -- Misfire monitor Fuel System Mon -- Fuel System Monitor Comp. Component -- Comprehensive Components Monitor EGR -- EGR System Monitor Oxygen Sens Mon -- O2 Sensors Monitor Catalyst Mon -- Catalyst Monitor EVAP System Mon -- Evaporative System Monitor Oxygen Sens htr -- O2 Sensor Heater Monitor Sec Air System -- Secondary Air Monitor Htd Catalyst -- Heated Catalyst Monitor A/C Refrig Mon -- A/C system Monitor 33 . . . . . . . . . . . . Since DTCs Cleared. . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHICAGO 99722

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CHICAGO 99722 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag