User manual CINO FUZZYSCAN WIRELESS SCANNER REFERENCE MANUAL REV A6

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CINO FUZZYSCAN WIRELESS SCANNER. We hope that this CINO FUZZYSCAN WIRELESS SCANNER user guide will be useful to you.

Lastmanuals help download the user guide CINO FUZZYSCAN WIRELESS SCANNER.


Mode d'emploi CINO FUZZYSCAN WIRELESS SCANNER
Download
Manual abstract: user guide CINO FUZZYSCAN WIRELESS SCANNERREFERENCE MANUAL REV A6

Detailed instructions for use are in the User's Guide.

[. . . ] WIRELESS IMAGER Reference Manual International Edition, Rev. A1 Released Date Oct 16, 2009 Oct 22, 2009 First Release Page 6 Page 68 Page 53 Page 69 Rev. A3 Mar 05, 2010 Page 25 Page 43 Page 45 Page 48 Page 49 Rev. A4 Apr 27, 2010 Page 38 Page 43 Page 27 Rev. [. . . ] UPC-A/E Standardization : Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion. UPC Lead 1 Numeric System : Enable to read UPC leading with the 1 numeric system, you must enable this option. WPC Selection (UPC/EAN/CAN) UPC-A UPC-E EAN-13 EAN-8 Basic Length 12 8 13 8 Disable Check Digit -1 -1 -1 -1 Disable Numeric System -1 -1 NC NC With 2-digit Addendum +2 +2 +2 +2 With 5-digit Addendum +5 +5 +5 +5 Enable Standardization +1 +1 NC NC Enable Expansion 0 +4 0 +5 24 Configure Your FuzzyScan Symbology Reading Control UPC-A & UPC-E Setting PROGRAM Family Code Selection UPC Supplement Setting P. C SS SS SS SS SS SS SS SS SS SS SS F_DEFAULT Parameter Selection Select UPC without supplement digits Select UPC with only 2 supplement digits Select UPC with only 5 supplement digits Select UPC with 2/5 supplement digits Disable force supplement digits output Enable force supplement digits output UPC Family Addenda Separator Off UPC Family Addenda Separator On Level 0 Level 1 Level 2 Only available for UPC-A & EAN-13 Option Code 0 1 2 3 4 5 6 7 0 1 2 UPC/EAN Security Level Supplement Scan Voting Reference Manual Wireless FuzzyScan UPC/EAN Security Level The scanner offers three levels of decode security for UPC/EAN bar codes: Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this security level may significantly impair the decoding ability of the scanner. Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding "in-spec" UPC/EAN bar codes. Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may increase the misread. The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. When you select higher level, it may impact the reading speed on poorly-printed, low contrast or damage barcode labels. 25 SS SS SS SS SS SS SS None Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Level 8 Level 9 Level 10 Level 11 Level 12 Level 13 0 1 2 3 4 5 6 7 8 9 A B C D Configure Your FuzzyScan Symbology Reading Control EAN Setting PROGRAM Family Code Selection EAN Setting P. C SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS F_DEFAULT Parameter Selection Disable EAN-13 Enable EAN-13 Disable EAN-8 Enable EAN-8 Disable EAN-8 expansion Enable EAN-8 expansion Disable EAN-13 check digit transmission Enable EAN-13 check digit transmission Disable EAN-8 check digit transmission Enable EAN-8 check digit transmission Disable ISBN/ISSN Conversion reading check Enable ISBN/ISSN Conversion reading check Select EAN without supplement digits Select EAN with only 2 supplement digits Select EAN with only 5 supplement digits Select EAN with 2/5 supplement digits Disable force supplement digits output Enable force supplement digits output EAN Addenda Separator Off EAN Addenda Separator On None Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Level 8 Level 9 Level 10 Level 11 Level 12 Level 13 0 1 2 3 4 5 6 Option Code 0 1 2 3 4 5 6 7 8 9 A B 0 1 2 3 4 5 6 7 7 8 9 A B C D EAN Supplement Setting Reference Manual Wireless FuzzyScan Supplement Scan Voting The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. When you select higher level, it may impact the reading speed on poorly-printed, low contrast or damage barcode labels. 26 Configure Your FuzzyScan Symbology Reading Control EAN Setting PROGRAM Family Code Selection UPC/EAN Security Level P. C SS SS SS Level 0 Level 1 Level 2 Only available for UPC-A & EAN-13 F_DEFAULT Parameter Selection Option Code 0 1 2 EAN Supplement Control SS SS SS SS SS SS SS SS Disable all specific prefix supplement digital output Enable all specific prefix supplement digital output Enable 491 Supplement Digit Output Enable 978/979 Supplement Digit Output Enable 977 Supplement Digit Output Enable 378/379 Supplement Digit Output Enable 414/419 Supplement Digit Output Enable 434/439 Supplement Digit Output 0 1 2 3 4 5 6 7 Reference Manual Wireless FuzzyScan UPC/EAN Security Level The scanner offers three levels of decode security for UPC/EAN bar codes: Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this security level may significantly impair the decoding ability of the scanner. Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding "in-spec" UPC/EAN bar codes. Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may increase the misread. EAN Supplement Control If you select EAN with only 2, or 5 or 2/5 supplement digits and enable 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5 or 2/5 supplement digits bar codes starting with 491 prefix. [. . . ] Scan "3rd Insertion" and set the identified position to "16", then inserted character to "09". In the final, you must scan "FIN" (Finish) code to terminate this selection. [Important Notice] Please note that Condensed DataWizard will follow the preset working flow as below: Verifier Formatter Replacer Organizer So when you set the identified position in Data Organizer, you must consider the inserted data which you already set via Data Formatter. 63 Appendix Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character c = Code Character m = Modifier Character Cino ID Code Family Primary Format Code Character UPC-A UPC-A with 2 supple. E A E Code Character AIM ID Modified Character m 1 2 m 1 2 EAN/JAN EAN/JAN-8 EAN/JAN-8 with 2 supple. F E N E Code Family Primary Format Cino ID Code Character Code Character AIM ID Modified Character 4 1 2 m 1 2 Example: A UPC-A bar code 012345678950 with 2 supplement 12 is transmitted as ]E0012345678950]E112 Code 128 Code 128 UCC/EAN-128 Codabar/NW-7 Standard/Industrial 2 of 5 Matrix 2 of 5 Code 25 Interleaved 2 of 5 China Postal Code German Postal Code IATA IATA UCC Coupon Code B C D I K J L M O Z C F S X I X I R m 1 m 0 0 m 0 3 m PDF417 Codablock Korea Post Code 93 Code 11 MSI/Plessey UK/Plessey Telepen GS1 DataBar Compsoite Code 39 Example: A EAN/JAN-8 bar code 49123562 with 5 supplement 12345 is transmitted as ]E449123562]E212345 Code 93 Code 11 MSI/Plessey UK/Plessey Telepen GS1 Databar Composite Code Code 39 Code 39 Trioptic Code 32 PDF417/Micro PDF417 Codablock F Korea Post Code H P R S T X G W G V Y a G H M P B e A X A L O X m m m 0 m 0 m 0 0 0 0 0 Reference Manual Codabar Wireless FuzzyScan Example : A UPC-A 512345678900 + UCC/EAN-128 81010123451297 UCC Coupon bar code is transmitted as]E0512345678900]C181010123451297 Example: A EAN-13 9923456789019 + UCC/EAN-128 81010123451297 bar code is transmitted as ]E09923456789019]C181010123451297 Remark: Above examples are given for the transmission of AIM ID. 64 Appendix Keyboard Function Code Table No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CINO FUZZYSCAN WIRELESS SCANNER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CINO FUZZYSCAN WIRELESS SCANNER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag