User manual CISSELL CF 41

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CISSELL CF 41. We hope that this CISSELL CF 41 user guide will be useful to you.

Lastmanuals help download the user guide CISSELL CF 41.


Mode d'emploi CISSELL CF 41
Download
Manual abstract: user guide CISSELL CF 41

Detailed instructions for use are in the User's Guide.

[. . . ] - WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Clear the room, building, or area of all occupants. Immediately call your gas supplier from a neighbor's phone. [. . . ] This will assure proper operation of trap when connected. After flushing system, install bucket trap (with built-in strainer) and check valve. For successful operation of dryer, install trap 18" below coil and as near to the dryer as possible. Inspect trap carefully for inlet and outlet markings and install according to trap manufacturer's instructions. If steam is gravity returned to boiler, omit trap but install check valve in return line near dryer. Install union and globe valve in return line and make final pipe connections to return header. Page 18 Steam Piping Installation (Illustration) Page 19 Dryer Installation With Multiple Exhaust For Exhaust Duct less than 14 feet (5 m) and 2 elbows equivalent and less than 0. 3 inches (. 8 mbar)static pressure. DRYER EXHAUSTS Area of section A-A must be equal to the sum of dryer exhaust pipes entering multiple exhaust pipe. of Dryers Duct Diameter (in inches) (in CM) HD30 123 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 8 12 14 16 18 20 22 23 24 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 20 30 35 41 46 51 56 58 61 66 68 71 73 76 78 81 84 86 89 91 94 97 99 100 Exhaust Booster Fan Power Supply to Fan ____ ____ ____ ____ ____ ____ Relay Coils Start and Stop Switches on Dryers Page 20 Dryer Installation with Multiple Exhaust DRYER INSTALLATION WITH MULTIPLE EXHAUST For Exhaust Duct more than 14 feet (5 m) and 2 elbows equivalent and more than 0. 3 inches (. 8 mbar) static pressure. Make-up air from outside building may enter enclosure from top or side walls. (See Dryer Make-Up Air Chart on page 22) Use constant diameter duct with area equal to the sum of dryer duct areas. EXAMPLE: Six 8 inch (204 mm) diameter ducts = one (1) 19. 6 inch (498 mm) diameter duct in area. Use 20 inch (508 mm) diameter duct or diameter to match tube-axial fan. After the first 4" (102 mm), the ceiling clearance required is 6" (153 mm). The rear clearance required is 0", and the side clearance is 0" . Heat loss into laundry room from dryer front panels is about 60 Btu/h per square foot (15 kcal/h per 0. 1m²). 3. 4. Page 23 Exhaust and Venting DRYER AIR FLOW INSTALLATION Nothing is more important than air flow for the proper operation of a clothes dryer. A dryer is a pump which draws make-up air from the out-of-doors, through the heater, through the clothes and then forces the air through the exhaust duct back to the out-of-doors. Just as in a fluid water pump, there must be a fluid air flow to the inlet of the dryer, if there is to be the proper fluid air flow out of the exhaust duct. In summary, there must be the proper size out-of-doors inlet air opening and an exhaust duct, size and length of which allows flow through the dryer with no more than 0. 3 inches water column (. 8 mbar) static pressure in the exhaust duct. In some instances, special fans are required to supply make-up air, and/or booster exhaust fans are required. Exhaust duct maximum length 14 feet (5 mm) of straight duct and maximum of two 90° bends. Use 45° and 30° elbows wherever possible. Do not install wire mesh or other restrictions in the exhaust duct. Use clean-outs in the exhaust duct and clean periodically when needed. [. . . ] Description 110-120/60/1 Motor Part No. Description 1 2 3 4 5 6 7 8 9 10 11 12 13 C249 DA-00460-0 **** DA-00516-0 TU14689 DSA-00772-0 DSA-00773-0 SB-00813-0 SB-00847-0 TU15227 TU2473 TU2474 TU2814 TU5439 VSB130 Nut, 5/16-18 (4 each) Seal Motor, see chart on page Sheave, 2 dia. (60 Hz) Sheave (50 Hz) Fan 11 machined (60 HZ) Fan 12 machined (50 HZ) Nut, 1/2-20 left hand rev. (2 each) Motor mount Gasket, curved (2 each) Gasket, cork 8 (2 each) Washer, lock 5/16 (4 each) Screw, cap HH 5/16-18 (4 each) Washer, cut 5/16 (4 each) DA-00428-0 SINGLE MOTOR MTR314 FAN-DOUBLE MOTOR MTR315 BASKET-DOUBLE MOTOR Page 50 DA-00428-0 SINGLE MOTOR MTR314 FAN-DOUBLE MOTOR MTR315 BASKET-DOUBLE MOTOR 200-240/50/1 DA-00428-0 SINGLE MOTOR MTR314 FAN-DOUBLE MOTOR MTR315 BASKET-DOUBLE MOTOR 200-240/60/3 DA-00447-0 SINGLE MOTOR MTR313 FAN-DOUBLE MOTOR DA-11909-0 BASKET-DOUBLE MOTOR 440-480/60/3 DA-00447-0 SINGLE MOTOR MTR313 FAN-DOUBLE MOTOR DA-11909-0 BASKET-DOUBLE MOTOR 220-240/50/3 DA-00447-0 SINGLE MOTOR DA-11907-0 FAN-DOUBLE MOTOR DA-11909-0 BASKET-DOUBLE MOTOR 380-415/50/3 SAME AS 220-240/50/3 200-240/60/1 MOTOR ASSEMBLY- REVERSING Ref. No. Part No. Description 1 2 3 4 5 DA-11909-0 TU11184 TU14690 VSB130 TU2814 TU5439 1/2HP 200-415/50-60/3 Sheave, 1. 8 dia. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL CF 41

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL CF 41 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag