[. . . ] The drying temperature may be set from 100°F (38°C) to 185/195°F (85/91°C). The drying time, cooling time, or temperature may be modified during an operating cycle. If it is necessary to reset the drying and cooling times for the current cycle, press STOP once to stop the dryer. If it is necessary to change programs during a current cycle, press STOP once to stop the dryer and press STOP again to cancel the current cycle Page 2 Diagnostic Microprocessor Control (DMP) 3. 0 DIP Switch Settings The DMP has an 8-position DIP switch bank that is accessible from the back of the control board. [. . . ] 6. 4 Press and hold the reverse button (REV) for 3 seconds to display the clockwise time. 6. 5 Use the UP/DOWN arrows to set the clockwise time within the range of 30-120 seconds. 6. 6 Press REV to display the dwell time. 6. 7 Use the UP/DOWN arrows to change the dwell time within the range of 3-10 seconds. 6. 8 Press the REV button to display the counter-clockwise time. 6. 9 Use the UP/DOWN arrows to change the counter-clockwise time within the range of 30-120 seconds. 6. 10 Press the REV button to save these settings and leave DIP Switch #3 in the ON position and flip DIP Switch #8 to the OFF position. When the DMP controller is retrofitted to an existing dryer with the reversing feature, off board reversing will be required and DIP Switch #3 on the DMP must be in the OFF position and the DMP must be connected to the Reversing Timer Board, Cissell part # TU12874 for proper operation. The DMP settings for clockwise, dwell, and counter-clockwise times are no longer valid when used with the Reversing Board. Instead these settings are made on the Reversing Timer Board. 4. 1 4. 2 4. 3 4. 4 4. 5 4. 6 Page 4 DIAGNOSTIC MICROPROCESSOR CONTROL - FEATURES 7. 0 Rotation Sensor The rotation sensor must read the key on the basket shaft. The sensor must be set approximately 1/4" from the key. Look for the light on the sensor to come on as the key passes the sensor; this is a correctly operating sensor. If no light appears either the sensor is out of range of the key or the sensor is bad. In addition, if the light stays on continuously then the se nsor is too close to the shaft or the sensor is bad. 7. 1 Safety Tumble/Anti-Wrinkle At the end of the cooldown cycle, the dryer will stop and display END. The DMP control will automatically rotate the basket for 5 seconds every 2 minutes for a total of 20 minutes, until some function of the dryer is activated/deactivated by the user. 8. 0 Operational Check for the Board Diagnostics 8. 1 dor indicates that the loading door is open. 8. 2 ldr indicates that the lint door is open. 8. 3 Cycle the dryer to check if the buzzer activates. 8. 4 P-F indicates that the thermistor is short circuited or open circuited. 8. 5 Hold the sail switch shut for a few seconds during start up -- Display reads FSS. To clear the display, release the sail switch to normal operation, press STOP then press START. [. . . ] Setting DIP switch # 7 to the OFF position will return the display to PAy. 17. 0 Description of Coin Control Panel (See illustration on page 10) 1. Starts or resumes the current program or cycle. Used for programming in the coin mode - increases or decreases the value in the display. In conjunction with the START button, these buttons are used to adjust the drying time, cooling time, temperature, clockwise time, dwell time, counter-clockwise time, and minutes per coin. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL DMP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL DMP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag