User manual CISSELL KMAN589

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CISSELL KMAN589. We hope that this CISSELL KMAN589 user guide will be useful to you.

Lastmanuals help download the user guide CISSELL KMAN589.


Mode d'emploi CISSELL KMAN589
Download
Manual abstract: user guide CISSELL KMAN589

Detailed instructions for use are in the User's Guide.

[. . . ] Charges for unauthorized repairs will not be accepted or paid by Cissell. CISSELL MAKES NO OTHER EXPRESSED OR IMPLIED WARRANTY, STATUTORY OR OTHERWISE, CONCERNING THE EQUIPMENT OR PARTS INCLUDING, WITHOUT LIMITATION, A WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, OR A WARRANTY OF MERCHANTABILITY. THE WARRANTIES GIVEN ABOVE ARE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. CISSELL NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER WARRANTY OR LIABILITY IN CONNECTION WITH THE MANUFACTURE, USE OR SALE OF ITS EQUIPMENT OR PARTS. [. . . ] Defective check valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Buck Valve leaking externally . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Head Valve leaking externally . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No head steam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 12 12 13 13 13 13 13 13 13 Page 4 TESTING This press has been tested in the Cissell factory to determine that it is safe and in working order. Final adjustments must be made to obtain the best results for your garments using your steam and vacuum in your environment. The Cissell presses are manufactured and tested to the highest standards. The steam pressure vessels have been tested with liquid to a pressure of 250 psi (17 bars). They have been tested for leaks with live steam at a pressure of 88 psi (6 bars). On request, we can supply pressure certification and information regarding sizes and wall thickness of the vessel(s). FOREWORD Manual Foot Operated Presses These modern presses are precision engineered to provide faster, easier operation than any other foot operated press. The head is closed by hand and by foot operation of the central pedal. The head is opened by pressing down on the lever on the right of the head steam valve. The head steam is hand lever operated while the buck steam and vacuum are foot pedal operated. The improved leverage system and roller bearing pivot assures smoother, faster head operation and a quality finish. Page 5 INSTALLING THE PRESS 1. 3. Uncrate the press and remove the skid. Hold the head down and cut the twine that holds the head closed. Allow the head to rise slowly to the open position. The Lowboy bracket (PR356) has been installed on the table at the factory. Then assemble the iron rest assembly (PR365, PR398 & PR401) to the shaft of PR356. (See Figure 1) FIGURE 1 (IRON REST) Page 6 INSTALLING THE PRESS (Continued) Steam and Vacuum Connections ­ (See Figure 2) 5. Connect a 3/8 inch steam supply line to the press at a recommended pressure of 88 psi (6 bars). Use a reducing valve if needed to obtain the correct pressure. [. . . ] A 3/8 inch supply and return line has been used. Buck Valve Leaking Externally_________________________________________________________ Cause Remedy Worn gasket Replace teflon gasket (PR261) if leaking between buck valve and buck. Head Valve Leaking Externally_________________________________________________________ Cause Remedy Worn gasket. Replace teflon gasket (PR260) if leaking at base of valve. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL KMAN589

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL KMAN589 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag