User manual CISSELL MANHD75ST

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CISSELL MANHD75ST. We hope that this CISSELL MANHD75ST user guide will be useful to you.

Lastmanuals help download the user guide CISSELL MANHD75ST.


Mode d'emploi CISSELL MANHD75ST
Download
Manual abstract: user guide CISSELL MANHD75ST

Detailed instructions for use are in the User's Guide.

[. . . ] HD STACK LAUNDRY DRYER Gas: Natural and LP Steam HD75ST Cissell Manufacturing Co. 831 S. - 40232-2270 Tel: (502) 587-1292 - Fax: (502) 585-2333 Sales Fax: (502) 585-3625 - Service/Parts Fax: (502) 681-1275 THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER Page 1 MANHD75ST 05/02 IMPORTANT NOTICES--PLEASE READ For optimum efficiency and safety, we recommend that you read the manual before operating the equipment. Store this manual in a file or binder and keep for future reference. WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or loss of life. [. . . ] (35 kg) Stack Dryer. Page 22 Exhaust and Venting DRYER AIR FLOW INSTALLATION Nothing is more important than air flow for the proper operation of a clothes dryer. A dryer is a pump which draws make-up air from the out-of-doors, through the heater, through the clothes and then forces the air through the exhaust duct back to the out-of-doors. Just as in a fluid water pump, there must be a fluid air flow to the inlet of the dryer, if there is to be the proper fluid air flow out of the exhaust duct. In summary, there must be the proper size out-of-doors inlet air opening (4-6 times the combined areas of the air outlet) and an exhaust duct, size and length of which allows flow through the dryer with no more than 0. 3 inches water column static pressure (8. 8 mbar) in the exhaust duct. In some instances, special fans are required to supply make-up air, and/or boost exhaust fans. Exhaust duct maximum length 14 feet (5 m) of straight duct and maximum of two 90° bends. Use 45° and 30° elbows wherever possible. Do not install wire mesh or other restrictions in the exhaust duct. Use clean-outs in the exhaust duct and clean periodically when needed. Never exceed 0. 3 inches water column static pressure (8. 8 mbar) in the exhaust duct. Inside surface of the duct must be smooth. Round ducting recommended. FOR BEST DRYING: 1. MAKE-UP AIR Provide opening to the out-of-doors in accordance with the following: Each 75 lb. Stack Dryer requires 4 square feet (. 4 m²) of make-up air. Use barometric shutters in the inlet air opening to control air when dryers are not running. Other Recommendations To assure compliance, consult local building code requirements. Troubleshooting Hot dryer surfaces, scorched clothes, slow drying, lint accumulations, or air switch malfunction are indicators of exhaust duct and/or make-up air problems. Page 23 Rules for Safe Operation of Dryer RULES FOR SAFE OPERATION OF DRYER 1. Be sure your dryer is installed properly in accordance with the recommended instructions. CAUTION Be safe--shut main electrical power supply and gas supply off externally before attempting service. CAUTION Never use drycleaning solvents: gasoline, kerosene, or other flammable liquids in the dryer. Never put fabrics treated with these liquids into the dryer. Never use heat to dry items that contain plastic, foam or sponge rubber, or rags coated with oils, waxes or paints. [. . . ] BUSHING, HINGE DELRIN COVER PLATE FRONT PANEL - COIN HINGE, CAST POST SCREW, HEX HD 5/16-18 HANDLE LATCH, DELRIN FRICTION PIN, CATCH 11 12 13 14 15 16 17 18 19 TU3213 TU3215 TU3209 TU5288 TU4840 TU5859 TU7169 TU7733 TU7862 RIVET 10-32 SCREW SCREW, SHT. #14 BASKET DOOR SEAL #10-32 HEX CROWN NUT BSKT DR, STANDARD GASKET, DOOR GLASS #8 x 1/2 S. M. SCREW GLASS, DOOR 20-1/4 Page 46 Motor Control Box Assembly - Reversing Shown Ref. 1 2 3 4 5 6 7 EA-00685-0 RC344 TUT194C TUT248D TUT289C TU12874 TU13515 TU13480 TU13514 TU13516 TU7733 Description 24V Reversing contactor 1/4-20 H. H. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL MANHD75ST

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL MANHD75ST will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag