User manual CISSELL SMPMANDFE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CISSELL SMPMANDFE. We hope that this CISSELL SMPMANDFE user guide will be useful to you.

Lastmanuals help download the user guide CISSELL SMPMANDFE.


Mode d'emploi CISSELL SMPMANDFE
Download
Manual abstract: user guide CISSELL SMPMANDFE

Detailed instructions for use are in the User's Guide.

[. . . ] - Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS Do not try to light any appliances. Do not touch any electrical switch; do not use any phone in your building. Clear the room, building, or area of all occupants. [. . . ] Before connecting trap and check valve to dryer, open globe valve in steam supply line and allow steam to flow through dryer to flush out any dirt and scale from dryer. This will assure proper operation of trap when connected. After flushing system, install bucket trap (with built-in strainer) and check valve. For successful operation of dryer, install trap 18" below coil and as near to the dryer as possible. Inspect trap carefully for inlet and outlet markings and install according to trap manufacturer's instructions. If steam is gravity returned to boiler, omit trap but install check valve in return line near dryer. Install union and globe valve in return line and make final pipe connections to return header. Page 18 Steam Piping Installation (Illustration) Page 19 Dryer Installation With Multiple Exhaust For Exhaust Duct less than 14 feet (5 m) and 2 elbows equivalent and less than 0. 3 inches (8 mm) static pressure. DRYER EXHAUSTS Area of section A-A must be equal to the sum of dryer exhaust pipes entering multiple exhaust pipe. of Dryers Duct Diameter (in inches) (in CM) HD75 123 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 8 12 14 16 18 20 22 23 24 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 20 30 25 41 46 51 56 58 61 66 68 71 73 76 78 81 84 86 89 91 94 97 99 100 Exhaust Booster Fan Power Supply to Fan ____ ____ ____ ____ ____ ____ Relay Coils Start and Stop Switches on Dryers Page 20 Dryer Installation with Multiple Exhaust DRYER INSTALLATION WITH MULTIPLE EXHAUST For Exhaust Duct more than 14 feet (5 m) and 2 elbows equivalent and more than 0. 3 inches (8 mm) static pressure. Make-up air from outside building may enter enclosure from top or side walls. (See Dryer Make-Up Air Requirements Chart) 2. Use constant diameter duct with area equal to the sum of dryer duct areas. Zero inches (mm) clearance to combustible material allowed on sides and at points within 4 inches (102 mm) of front on top. Heat loss into laundry room from dryer front panels is about 60 btu/hr per square foot (15 kcal/hr per 0. 1m). Page 23 Exhaust and Venting DRYER AIR FLOW INSTALLATION Nothing is more important than air flow for the proper operation of a clothes dryer. A dryer is a pump which draws make-up air from the out-of-doors, through the heater, through the clothes and then forces the air through the exhaust duct back to the out-of-doors. Just as in a fluid water pump, there must be a fluid air flow to the inlet of the dryer, if there is to be the proper fluid air flow out of the exhaust duct. In summary, there must be the proper size out-of-doors inlet air opening (4-6 times the combined areas of the air outlet) and an exhaust duct, size and length of which allows flow through the dryer with no more than 0. 3 inches water column (. 8 mbar) static pressure in the exhaust duct. In some instances, special fans are required to supply make-up air, and/or boost exhaust fans are required for both regular and energy saving models. Exhaust duct maximum length 14 feet (5 m) of straight duct and maximum of two 90 bends. Use 2 feet (0. 6 m) of straight duct on dryer before installing an elbow on Energy-Saver models only. Do not install wire mesh or other restrictions in the exhaust duct. Use clean-outs in the exhaust duct and clean periodically when needed. Never exceed 0. 3 inches water column (. 8 mbar) static pressure in the exhaust duct. [. . . ] 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Part No. TU2317 510101041 TU6722 TU5241 TM100 TU1851 TU2831 RC347 TU15517 MTR303 MTR301 TU33 IB140 TU4787 TU14414 VSB134 TU3246 TU4934 TU2846 TU2847 RC344 TU4684 TU8608 TU15516 510101040 TU7334 TU2833 Description BELT, V 4L-380 SHEAVE, AK39 (50 Cycle) SHEAVE, AK-51H (60 Cycle) KEY, 3/16 SQ. X 1" LONG REDUCER, GEAR-SMALL-METRIC WASHER WASHER, REG. 1/2-13 X 1-1/4 ROTATION SENSOR PICK UP BRKT MOTOR, 1 HP 3PH MOTOR, 1 HP 1 PH BRACKET, MTR DRIVE-28X36 DBLMT WASHER, FLAT 3/8" NUT, HEX 3/8-16 SENSOR/INDUC/ROTAT/BALLUFF WASHER, SPLIT LOCK 3/8 SCREW, CAP HEX HD 3/8-16 NUT, HEX 1/4-20 WASHER, LOCK 1/4 MEDIUM WASHER, CUT 1/4" SCREW, CAP H. H. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL SMPMANDFE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL SMPMANDFE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag