User manual CITIZEN CH-453

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CITIZEN CH-453. We hope that this CITIZEN CH-453 user guide will be useful to you.

Lastmanuals help download the user guide CITIZEN CH-453.


Mode d'emploi CITIZEN CH-453
Download
Manual abstract: user guide CITIZEN CH-453

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR REF CH-453 0902 English Contents 3 - GENERAL REMARKS 5 - PRECAUTIONS FOR USE AND MAINTENANCE 8 - IDENTIFICATIONS OF PARTS 10 - LOADING THE BATTERIES 11 - REMOVING THE BATTERIES 12 - MEASURING YOUR BLOOD PRESSURE 17 - TIPS FOR OBTAINING ACCURATE MEASUREMENTS 18 - CALLING UP THE DATA STORED IN MEMORY 20 - KEY TO DISPLAY ICONS 21 - ABOUT "BLOOD PRESSURE" 22 - BLOOD PRESSURE Q&A 23 - BEFORE REQUESTING REPAIRS OR TESTING 24 - SPECIFICATIONS Ensure that you have all the following components CH-453 Blood pressure monitor unit Cuff (for monitor) 4 AA-size batteries Instruction Manual - Eng 2 - GENERAL REMARKS 1. To deflate the cuff quickly, press the "START/STOP" switch. The attached cuff is suitable for arm circumferences of 22-32 cm. When attaching the cuff, adjust the position of the cuff so that the blue marker is located in the center of your arm and the hem of the cuff is 1 to 2 cm above your elbow. [. . . ] To clean the cuff, wipe it with a moist cloth. Avoid hard rubbing, as this will cause air leakages. Take care also not to get water into the air hose. 2. 8. Symbols Explanation: : The CE marking is meant to provide information to market inspectors in the EU member countries. : Type B applied part : Refer to instruction manual before use : Appliance compliance WEEE directive Pb : Accumulators and battery packs for separate collection : Manufacturer The device has been tested and homologated in accordance with EN60601-1-2 for EMC. This does not guarantee in any way that the device will not be affected by electromagnetic interference. Avoid using the device in high electromagnetic environment. Warning - Eng 6 - PRECAUTIONS FOR USE AND MAINTENANCE Nature and frequency of maintenance: English This product is designed for use over an extended period of time; however, it is generally recommended that it be inspected every two years to ensure proper function and performance. Protect the nature environment: Please help to protect natural environment by respecting national and/or local recycling regulations when disposing of the battery and the product at the end of their useful live. WEEE MARK If you want to dispose this product, do not mix with general household waste. There is a separate collection systems for used electronics products in accordance with legislation under the WEEE Directive (Directive 2002/96/EC) and is effective only within European Union. Information for Users on Collection and Disposal of used Batteries. The symbol in this information sheet means that used batteries should not be mixed with general household waste. For proper treatment, recovery and recycling of used batteries, please take them to applicable collection points. For more information about collection and recycling of batteries, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items. Pb Information on Disposal in other Countries outside the European Union. This symbol is only valid in the European Union. If you wish to discard used batteries, please contact your local authorities or dealer and ask for the correct method of disposal. Note for the battery symbol. The symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved. Reference European standard: The blood pressure measuring device corresponds to regulation EN60601-1-2. Calibration: The blood pressure measuring device is generally recommended to have the monitor inspected every two years to ensure correct functioning and accuracy. Please contact a distributor. Name : Address : CITIZEN SYSTEMS JAPAN CO. , LTD. 6-1-12, Tanashi-cho, Nishi-Tokyo-shi, Tokyo 188-8511, Japan European Representative: Name : Address : WvW electronishe Geräte Vertrieb GmbH Fintelmannstraße 20/Eingang, Martin-Heydert-Straße, D-14109 Berlin, Germany · For technical data, please contact our European Representative - Eng 7 - IDENTIFICATION OF PARTS Component names <Main Unit> Display* MEMORY Switch English Air hose socket START/STOP Switch a Stand-by *See page 9 for the display icons. Battery cover - Eng 8 - IDENTIFICATION OF PARTS <Cuff> English Pulse display Irregular Heartbeat (IHB) Indicator* Air hose Blue marker Metal hoop Air hose connector <Display> Battery icon Systolic blood pressure display Diastolic blood pressure display Memory icon Body Movement Indicator* * See page 15 for the Body Movement Indicator and Irregular Heartbeat (IHB) Indicator. - Eng 9 - LOADING THE BATTERIES (Batteries supplied with the unit should be loaded in compartment before you use the blood pressure monitor. ) English 1 Open the cover of battery compartment. Pressing the hook down, pull the cover toward you to open. 4 "AA" batteries Hook Battery compartment Battery cover Lug (projecting section) * If the Blood pressure monitor is left unused for an extended period of time, the batteries should be removed from the compartment. 2 Place batteries in the compartment. Put the batteries paying attention to the positive and negative terminal symbols m and , . - Eng 10 - LOADING THE BATTERIES 3 Close the battery cover. Fitting the lugs of the cover at the mating recesses of the battery compartment body, push the hook to close the cover. Fit the lugs (projections) at the recesses. REMOVING THE BATTERIES · When the icon is displayed, or nothing appears in the display, replace the old batteries with four new ones. All four batteries should be changed at once. · The memory is erased if the batteries are removed for replacement. It is recommended to make note of the data stored in memory prior to changing batteries. · Do not use rechargeable batteries. · Do not use alkaline (LR6) and manganese (R6P) batteries together. [. . . ] Knowing what affects your blood pressure helps you to better monitor your health. Why does the blood pressure obtained vary with measurement?Our blood pressure is adjusted by automatic nerve function. Blood pressure differs with every heart beat. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN CH-453

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN CH-453 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag