User manual COBRA CPI 300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual COBRA CPI 300. We hope that this COBRA CPI 300 user guide will be useful to you.

Lastmanuals help download the user guide COBRA CPI 300.


Mode d'emploi COBRA CPI 300
Download
Manual abstract: user guide COBRA CPI 300

Detailed instructions for use are in the User's Guide.

[. . . ] · Questions can be faxed to 773-622-2269. · Automated Technical Assistance is available 24 hrs. , 7 days a week via e-mail at: productinfo@cobra. com. · On-line answers to frequently asked questions can be found at: www. cobra. com For additional Customer Service information, see page 8-9. Table of Contents Introduction How Your Cobra® Power Inverter Works A2 A3 1 2-3 4 5 6 6 7 8-9 10 11 12 1 Rechargeable Appliances 2 Quick Checkout 3 Installation and Operation 4 Controls and Indicators 5 Operating Limits 5 Input Voltage/Automatic Shutdown 6 Troubleshooting Guide 7 Maintenance and Service 8 Power Consumption 9 Specifications 10 Limited 2-Year Warranty A3 1 RECHARGEABLE APPLIANCES QUICK CHECKOUT In order to check the performance of your CPI 300 before installing it, please have the following on hand: 1. A 12 volt DC power source (such as a vehicle battery) 2. [. . . ] Check to be sure all power connections are secure. POWER FAULT ON/OFF switch OFF ON CAUTION A reverse polarity connection (positive to negative) will blow the fuse in the inverter and may permanently damage the unit. CAUTION To prevent fire, do not cover or obstruct ventilation openings. Do not install the unit in a zero-clearance compartment. The inverter must only be connected to batteries with a nominal output voltage of 12 volts. It will not work with Testing Turn on the inverter. If the inverter does not appear to work properly, refer to the Troubleshooting Guide on page 7. The unit is now ready to deliver AC power to your loads. If several loads are to be powered by the inverter, turn them on separately AFTER the inverter has been turned on. This will ensure that the inverter will not have to deliver the start-up currents required for all loads at once. 4 4 CONTROLS & INDICATORS switched on for a few days. However, you should switch it off if you are not planning to recharge the battery within about a week. OPERATING LIMITS INPUT VOLTAGE/AUTO SHUTDOWN 5 On/Off Switch The ON/OFF switch turns the control circuit in the inverter on and off. It DOES NOT disconnect power from the inverter. AC Output AC Output POWER FAULT Power Output Your CPI 300 will deliver 300 watts continuously. It can deliver 360 watts for about 30 minutes, after which it must cool for about 15 minutes before it can resume operation at 300 watts. (NOTE: the wattage rating applies to resistive loads. ) Fault Indicator The "fault" indicator of your CPI 300 will light whenever the unit detects excessively high or low input voltage, or begins to overheat. AC Output AC Output POWER FAULT ON/OFF switch OFF ON When the switch is in the OFF position, the inverter draws no current from the battery. When it is the in ON position, but no power is being supplied to the load, the inverter draws less than 500 milliamperes from the battery. It would take more than a week to discharge a 100 ampere-hour battery at this draw rate. You don't have to worry about excessive drain on a battery if you leave the inverter 5 Input Voltage Your CPI 300 will operate from input voltage ranging from 10 to 15 volts. Optimum performance occurs when the voltage is between 12 and 14 volts. If the voltage drops below 10. 7 ± 0. 3 volts, an audible low battery alarm will sound. The inverter will automatically shut down if the input voltage drops below 10. 0 ± 0. 3 volts. This protects the battery from being overdischarged. The inverter will restart when the input voltage exceeds 12. 0 ± 0. 5 volts. The inverter will also shut down if the input voltage increases to 15. 0 ± 0. 5 volts. This helps protect the unit from damage due to excessive input voltage. Although the inverter is protected in this way, it may still be damaged should the input voltage exceed 16 volts. fault indicator Automatic Shutdown The unit will automatically go into thermal shutdown if it becomes overheated due to excessive input voltage, poor circulation or high ambient temperature. OFF ON 6 6 TROUBLESHOOTING GUIDE Possible Causes Overload Low input voltage Short circuit or wiring error Solution Reduce the load. [. . . ] The unit is completely insulated in input and output for added safety. Cobra Electronics Corporation warrants that its Cobra® Power Inverter, and the component parts thereof, will be free of defects in material and workmanship for a period of two (2) years from the date of consumer purchase. This warranty may be enforced by the first consumer purchaser, provided that the product is utilized within the U. S. A. Cobra® will, without charge, repair or replace, at its option, a defective inverter upon delivery to the Cobra® Factory Service Department, accompanied by proof of the date of first consumer purchase, such as duplicated sales receipt. You must pay initial shipping charges required to ship the product for warranty service, but the return charges will be at Cobra's expense, if the product is repaired or replaced under warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE COBRA CPI 300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual COBRA CPI 300 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag