User manual CONTAX PCB-90

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CONTAX PCB-90. We hope that this CONTAX PCB-90 user guide will be useful to you.

Lastmanuals help download the user guide CONTAX PCB-90.


Mode d'emploi CONTAX PCB-90
Download

You may also download the following manuals related to this product:

   CONTAX PCB-90 DATASHEET (40 ko)

Manual abstract: user guide CONTAX PCB-90

Detailed instructions for use are in the User's Guide.

[. . . ] PCB-90 DC SUBMERISIBLE PUMP CONTROLLER USER'S MANUAL PCB-90C SERIES SOLARJACK'S HIGH VOLTAGE PC SERIES PUMP CONTROLLERS SOLARJACK'S PC series controllers are state-of-the-art solid state power converters designed as an interface between a SOLARJACK pump and the DC power source. The purpose of this controller is to maximize the total daily water output while providing protection for the pump as well as the power source. The unique features incorporated in this controller will protect the pump system insuring many years of dependable, trouble free service. When used in a solar panel direct system it provides protection for the pump from over-voltage and over-current conditions and will provide current boosting in low sunlight conditions. [. . . ] Switch #2 in the on position allows the pump to run when terminals 7 and 8 are connected. This is generally used in conjunction with a float switch or a pressure switch which makes contact to run the pump. Switch #2 in the off position allows the pump to run when terminals 7 and 8 are disconnected. This is generally used in conjunction with a float switch which breaks contact to make the pump run. 12/6/1999 4 CONTROLLER ADJUSTING PROCEDURE CAUTION: THIS PROCEDURE SHOULD ONLY BE PREFORMED BY A QUALIFIED SOLAR ELECTRIC TECHNICIAN. THIS PROCEDURE IS NOT NECESSARY IF STANDARD 16. 5 TO 17 VOLT SOLAR MODULES ARE BEING USED. This procedure will not work on a centrifugal type pump such as an SCS submersible. It is only for positive displacement type pumps. The purpose of this procedure is to adjust the voltage of the PV array to its peak power point and thus obtain the maximum water delivery from the pump. This procedure should be performed with the panels at their normal operating temperature at mid-day. (Option 1) For panel voltage adjustment at the maximum power point. With the system installed and pumping water, turn the panels away from the sun until the pump flow rate is reduced by approximately 50%. If this is not possible then shade the panels slightly until you have obtained the same results. This puts the controller in a current boosting mode so this adjustment can be made. Connect a DC volt-meter to the pump side of the controller. (LD+ and LD-) Turn the small brass adjusting screw on the "Panel Voltage Adjusting Pot", located on the front of the controller, until the highest possible voltage is obtained. (If this controller is used on a Jack Pump system using a flywheel, there will be a slight delay from the time you make an adjustment to when a change in voltage will be noticed. ) Return the panels to their normal position. The pump will then operate at its maximum output. 2. 3. 4. (Option 2) For estimated panel voltage adjustment. With the system installed and pumping water, turn the panels away from the sun until the pump flow rate is reduced by approximately 50%. If this is not possible then shade the panels slightly until you obtain the same results. Connect a DC volt meter to the panel side of the controller. (PV+ and PV-) Estimate the proper voltage by multiplying the voltage rating of the panel's times the number of panels connected in series and deduct 20%. [. . . ] Make sure the proper panel voltage selector switch is on for your panel arrangement. (Switches 4-6 on the dip-switch. ) Note: If the incoming voltage is lower than the set point voltage, the controller will not turn on. IF THE RED AND GREEN LIGHTS ARE ON, WITH ALL OTHER LIGHTS OFF, AND THE PUMP DOES NOT RUN: (IN GOOD SUNLIGHT) 12/6/1999 6 4. Check for proper controller output voltage. Connect a DC volt meter across terminals 2 LD- and 3 LD+ on the large terminal block. If no voltage is indicated check the fuse. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONTAX PCB-90

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CONTAX PCB-90 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag