User manual CONTAX TRACE DR REV A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CONTAX TRACE DR. We hope that this CONTAX TRACE DR user guide will be useful to you.

Lastmanuals help download the user guide CONTAX TRACE DR.


Mode d'emploi CONTAX TRACE DR
Download
Manual abstract: user guide CONTAX TRACE DRREV A

Detailed instructions for use are in the User's Guide.

[. . . ] DR Series Inverter/Charger Installation & Operators Manual DR Series Inverter/Charger Table of Contents Section 1. 0 Description Page INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Model Identification and Numbering Conventions . . . . . . . . . . . . 3 Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Connect a (white) wire between the inverters NEUTRAL OUTPUT terminal and the NEUTRAL bus in the sub-panel. Connect a (black) wire between the inverters terminal labeled AC HOT OUTPUT and the SUB-PANELs INPUT circuit breaker. Torque all inverter terminal block connections to 16 inch-pounds. Refer to the sub-panel manufacturers specifications for wire torques. Recheck all connections. Refer to the illustration on the next page. 32 2000 Xantrex Technology Inc. 2. 0 INSTALLATION Generators (continued) Utility Power 120 VAC Bonded Neutral/ Ground Bus G R O U N D NEUTRAL HOT Main Utility Circuit Breaker N E U T R A L NEUTRAL Bond Wire Inverter Circuit Breaker HOT Utility Service Panel House Ground GENERATOR HOT CONTACT UTILITY HOT CONTACT COMMOMN CONTACT (to inverter) Manual Transfer Switch U C G HOT NEUTRAL Isolated Neutral Bus Manual Start Generator Generator Power AC Input Inverter AC Output Isolated Neutral Bus Main Input Breaker Isolated Neutral Bus NEUTRAL HOT GROUND To AC Load Sub-panel 975-0012-008 Figure 27 Basic 120 VAC Utility/Generator Block Diagram 2000 Xantrex Technology Inc. 33 2. 0 INSTALLATION Series Stacking This COM port allows two DR Series inverter/chargers to be used in the same system in a SERIES configuration to operate 240 VAC loads. Series stacking can also be used to connect to 240 VAC only power systems providing both 120 and 240 VAC outputs. A series stacking interface cable (DRI) is required to connect the series stacking port of the inverters. In this mode, one of the inverters will function as the primary and the other inverter becomes the secondary. The first unit switched ON becomes the primary and ensures the secondarys output is 180 degrees out of phase for 240 VAC operation. Both units can charge the batteries or provide battery backup power during a utility outage. The following illustrations provide a general overview of AC and DC wiring configurations and output voltages supplied by stacked inverters. Detailed wiring and operating instructions are provided with the DRI interface kit available from Xantrex Technology Inc. NOTE: Only 120 VAC/60 Hz models can be stacked. MAIN PANEL L1 L2 L1 N E U T R A L BOND WIRE GROUND HOT L1 L2 HOT L2 NEUTRAL IN HOT OUT NEUTRAL OUT NEUTRAL IN HOT IN DRI COM PORT GROUND NEUTRAL OUT GROUND INVERTER 1 (L1) SERIES STACKING CABLE (DRI) HOT OUT NEUTRAL OUT NEUTRAL IN HOT IN DRI COM PORT GROUND NEUTRAL OUT INVERTER 2 (L2) L1 N E U T R A L L2 L1 240 VAC SUB-PANEL GROUND L2 120 VAC 120 VAC GROUND 975-0012-D-014 Figure 28 Series Stacking AC Wiring (120 VAC/60 Hz models only) 34 2000 Xantrex Technology Inc. 2. 0 INSTALLATION Series Stacking (continued) Inverter 1 (L1) Positive Tie Negative Tie Series Stacking Cable (DRI) DC Disconnect Inverter 2 (L2) + + 975-0012-009 + + Figure 29 Stacking Port and Battery Wiring with One Disconnect (120 VAC/60 Hz models only) Inverter 1 (L1) Negative Tie DC Disconnect Series Stacking Cable (DRI) Inverter 2 (L2) + DC Disconnect + 975-0012-010 + + Figure 30 Stacking Port and Battery Wiring with Two Disconnects (120 VAC/60 Hz models only) 2000 Xantrex Technology Inc. 35 3. 0 OPERATION Front Panel Controls and Indicators All operating controls, indicators and sense connectors are located on the front panel of the unit. The controls are easily accessible, and the LEDs provide inverter/charger status at a glance. POWER ON/OFF Switch The POWER ON/OFF control is a momentary contact switch that turns the inverter/charger ON or OFF by pressing it once. When the inverter is first connected to the batteries, it will run through a self test consisting of flashing the LEDs in sequence, operating the cooling fan momentarily and switching the transfer relay three times. Once the self test has successfully completed, the POWER ON/OFF switch is activated. Pressing the switch once turns the inverter ON. Ports There are two ports on the inverter/charger. Both ports are RJ11 type telephone style connectors and are used for controlling the inverter and regulating the charger voltage based on temperature. COM PORT COM PORT (J1) is a dual function RJ11 (6-pin) connector. Its primary function is to provide serial communications to an optional Trace remote control unit (RC4 or RC8). [. . . ] This especially applies to situations where the products failure or malfunction can be reasonably expected to cause the failure or malfunction of the life support device, or to significantly affect its safety or effectiveness. Examples of life support devices include: neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia ventilators, and infusion pumps as well as any other devices designated as critical by the U. S. Xantrex will not knowingly sell its products for use in such applications unless it receives, in writing, assurances satisfactory to The Company, that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of Xantrex is adequately protected. Warranty Registration To ensure proper registration, complete the Warranty Card and mail it to Xantrex within 10 days from the date of original purchase. Also, keep your bill of sale as proof of purchase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONTAX TRACE DR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CONTAX TRACE DR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag