User manual CORTECH DATALOG 3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CORTECH DATALOG 3. We hope that this CORTECH DATALOG 3 user guide will be useful to you.

Lastmanuals help download the user guide CORTECH DATALOG 3.


Mode d'emploi CORTECH DATALOG 3
Download
Manual abstract: user guide CORTECH DATALOG 3

Detailed instructions for use are in the User's Guide.

[. . . ] Table of Contents INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Datalog 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Operation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 A Zone Input Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Click on the relevant area of the Map Viewer graphic below for more help. Map Selection Box The map selection box allows the operator to click on a map title and view the associated map. When the map is displayed it will show the zone positions either as symbols representing the type of alarm, or numbered and coloured Icons, depending on the setting of the Icon Display radio button. Icon Display When a map is selected and displayed in Map Viewer or Zone Inhibit, the map will show the zone positions by an icon representation. If the Icon Display radio button is set to `Symbol' The zone will be shown as a button like icon with a graphic that represents the type of alarm. Datalog 3 User Manual - Page 30 of 66 CORTECH DEVELOPMENTS LTD If the Icon Display radio button is set to `Numbers' The zone will be shown as a larger numbered, coloured button like icon displaying the zone number and state. Map Viewer Options When the `Options' radio button is set in the default state of `All Zones', the list at the bottom of the Map Viewer screen shows all the zones on the Datalog 3 system. Walk Test Status can be viewed on the Map Viewer Screen by setting the `Options' radio button to `Virtual Walk Test'. The list at the bottom of the screen will switch from showing the zone list to showing zones requiring a Walk Test. The default Walk Test list shows any zones that are more than I day past the Walk Test alarm period. Map Viewer Walk Test Options Walk Test Status can be viewed on the Map Viewer Screen by setting the `Options' radio button to `Virtual Walk Test'. The list at the bottom of the screen will switch from showing the zone list to showing zones requiring a Walk Test. The default Walk Test list shows any zones that are more than I day past the Walk Test alarm period. This list can be filtered by increasing the days past the Walk Test alarm period. To do this, remove the tick from the `Default 1 Day' check box in the Walk Test Options box, and entering the number of days in the `Days' field. The text `Walk Test Zones X' below the Days field shows how many zones have been found where X is the count of zones. If an icon is displayed next to the number of days since walk test, this indicates that this zone is omitted from the Walk Test. Datalog 3 User Manual - Page 31 of 66 CORTECH DEVELOPMENTS LTD Walk Test The Datalog 3 system can manage the site's zone testing by assisting with walk test procedures. The User Setup screen allows the user to define the period of days the system will allow a zone to operate without an alarm being received from that zone. Once that period expires, the system will generate an alarm to annunciate that a walk test is required. In addition the user can also set the number of days before the walk test alarm occurs that the system should issue a warning message. Walk Test Status can be viewed on the Map Viewer Screen by setting the `Options' radio button to `Virtual Walk Test'. The list at the bottom of the screen will switch from showing the zone list to showing zones requiring a Walk Test. The default Walk Test list shows any zones that are more than I day past the Walk Test alarm period. This list can be filtered further by increasing the days past the Walk Test alarm period. To do this, remove the tick from the `Default 1 Day' check box in the Walk Test Options box, and entering the number of days in the `Days' field Zones that have exceeded the walk test period will be logged and printed when an end of day analysis report is run. The information can also be reviewed in a Walk Test report, which is based on these settings. It may not be possible for site staff to walk test some zones, they may be inaccessible without special knowledge or equipment, such as equipment failure and tamper alarms. [. . . ] 34 Adding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Changing Your Password. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Deleting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Displaying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CORTECH DATALOG 3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CORTECH DATALOG 3 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag