User manual CREST AUDIO CPA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CREST AUDIO CPA. We hope that this CREST AUDIO CPA user guide will be useful to you.

Lastmanuals help download the user guide CREST AUDIO CPA.


Mode d'emploi CREST AUDIO CPA
Download
Manual abstract: user guide CREST AUDIO CPA

Detailed instructions for use are in the User's Guide.

[. . . ] PROFESSIONAL POWER AMPLIFIERS -6 -10 -15 -30 -80 0 dB -1 -3 ACL Signal -6 -10 -15 -3 CP A -1 Protect Active -30 -80 0 dB 1 800 Ch A Cinema Power Amplifier Ch B -6 -10 -15 -30 -80 0 dB -1 -3 ACL Signal -6 -10 -15 -3 CP A -1 Protect Active -30 -80 0 dB 1 200 Ch A Cinema Power Amplifier Ch B -6 -10 -15 -30 -80 -1 0 dB -3 ACL Signal Protect Active Cinema Power Amplifier -6 -10 -15 -30 -80 -1 0 dB -3 CP A 900 Ch A Ch B -6 -10 -15 -30 -80 -1 0 dB -3 ACL Signal Protect Active Cinema Power Amplifier -6 -10 -15 -30 -80 -1 0 dB -3 CP A 600 Ch A Ch B -6 -10 -15 -30 -80 -1 0 dB -3 ACL Signal Protect Active Cinema Power Amplifier -6 -10 -15 -30 -80 -1 0 dB -3 CP A 400 Ch A Ch B OWNER' S MANUAL Important Precautions This symbol is used to alert the operator to follow important operating procedures and precautions detailed in documentation. This symbol is used to warn operators that uninsulated "dangerous voltages" are present within the equipment enclosure that may pose a risk of electric shock. 10. Power down and disconnect units from mains voltage before making connections. Never hold a power switch in the "ON" position if it won't stay there itself! [. . . ] Drawn in by dual 45 cubic feet-per-minute (CFM) fans on the rear panel, air flows through the cooling fins of the channel heat sinks (dissipating power transistor heat), then exhausts through the front panel slots. The "intelligent" variable-speed DC fans are controlled by heat sink temperature-sensing circuits. When the amplifier is turned on, the fans briefly "rev up, " then slow to an idle; this indicates that the temperature sensing circuits are operating normally. The fan speed increases only as required by heat sink temperatures, keeping fan noise to a minimum. Under extreme thermal load, the fans will force a very large volume of air through the heat sinks. If either heat sink surpasses the maximum allowed temperature, the sensing circuit will open the output relay, disconnecting the load from that channel. If the power transformer overheats, another sensing circuit opens both channel output relays until the transformer cools to a safe temperature. IMPORTANT: To ensure optimum cooling, periodically clean the amplifier fan filters (removable without tools). Also make certain that there is enough space around the front of the amplifier to allow the cooling air to escape. If the amplifier is rack-mounted, do not use doors or covers on the front of the rack; the exhaust air must flow out without resistance. If the amplifiers are to be housed in racks with closed backs, allow at least one (1) standard rack space of opening in the front of the rack for every four amplifiers. Crest Audio CPA Series Power Amplifiers Models CPA400, CPA600, CPA900, CPA1200, CPA1800 Page 9 Connecting Inputs. Use either the XLR or 1/4-inch input connectors on the rear to supply audio signals to your Crest Audio CPA Series amplifier. Both connectors accept balanced and unbalanced audio connections. (The CPA Series amplifiers are configured standard with "Pin 2 hot" on XLR inputs. Please note that some other Crest Audio amplifiers are configured with "Pin 3 hot"). The unused connector can be used to jumper the audio input to another amplifier input. For more information, see the sections on Balanced 1/4" (TRS) & XLR Input Connectors, Input XLR Polarity, and Input Sensitivity. Speakers are connected using 5-way Output Binding Posts or Speakon connectors, depending on version supplied. Please note that on the 5-way Output Binding Post version of the CPA1800, two pairs of 5-way binding posts are provided for each channel, so that paralleling of speakers is possible. For more information, see the Output Connectors and Mode Selection sections. Page 10 Crest Audio CPA Series Power Amplifiers Models CPA400, CPA600, CPA900, CPA1200, CPA1800 Mode Selection. The three-position, recessed Mode Select switch (located on the rear panel) configures the amplifier for either Stereo, Parallel or Bridged Mono Mode. Amplifiers are factory-configured for Stereo Mode. In Stereo Mode, both channels operate independently, with their input attenuators controlling their respective levels. [. . . ] Because of the complexity of the design and the risk of electrical shock, all repairs should be attempted only by qualified technical personnel. If the unit needs to be shipped back to the factory, it must be sent in its original carton. If improperly packed, your amplifier may be damaged. For those with Internet access, please visit the Crest Audio website at: http://www. crestaudio. com Page 16 Crest Audio CPA Series Power Amplifiers Models CPA400, CPA600, CPA900, CPA1200, CPA1800 Appendices Appendix A - Amplifier Specifications 1kHz, 0. 1% THD+N 8 Stereo Power 4 Stereo Power 8 Bridged Mono Power 20Hz-20kHz, 0. 1% THD+N 8 Stereo Power 4 Stereo Power 8 Bridged Mono Power Max RMS Output Voltage (each channel) Max Peak Output Voltage Frequency Response (+0 / -0. 3dB, 1W/8) Power Bandwidth (rated power at 4, 1%THD+N) TourClass Protection THD+N (rated power, 4/1kHz) SMPTE IMD (rated power, 8, 60 Hz & 7kHz) Damping Factor (10-400Hz at 8) Input CMRR (1kHz) Standard Input Sensitivity (rated power at 8) Standard Voltage Gain (rated power @ 8) Input Impedance (balanced/unbalanced) Hum and Noise ("A" weighted, -80 dBW) Crosstalk ("A" weighted, full power at 4) Class Input Connectors (per channel) Output Connectors (per channel) Filter Storage Power Supply (factory configured) Idle Current Draw (120V) 1/8 Power Curr. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CREST AUDIO CPA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CREST AUDIO CPA will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag