If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON CLT-1DELV4 CLX-1DELV4. We hope that this CRESTRON CLT-1DELV4 CLX-1DELV4 user guide will be useful to you.

Lastmanuals help download the user guide CRESTRON CLT-1DELV4 CLX-1DELV4.


Mode d'emploi CRESTRON CLT-1DELV4 CLX-1DELV4
Download
Manual abstract: user guide CRESTRON CLT-1DELV4 CLX-1DELV4

Detailed instructions for use are in the User's Guide.

[. . . ] shown in the next column when considering the location of terminal blocks and modules within an enclosure. NOTE: Modules and terminal blocks must be installed into the lowest available spaces and continue toward the top of the enclosure. Terminal Block & Module Locations (Single-wide Enclosure) GROUNDING TERMINAL TERMINAL BLOCK BLOCK MODULE CLX-1DELV4 1 FEED 4 DIM 120VAC 60 Hz 16A MAX 9A MAX/CKT LINE DIM 1 DIM 2 DIM 3 DIM 4 N IN N OUT 1 N OUT 2 N OUT 3 N OUT 4 CRESTRON Industry Compliance This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. Terminal Block & Module Locations (Double-wide Enclosure) (E103692) TERMINAL BLOCK (LEFT) MODULE TERMINAL BLOCK (RIGHT) Installation The terminal block and module must be mounted into a Crestron Automation Enclosure by a licensed electrician, in accordance with all national and local codes. CAUTION: This equipment is for indoor use only and needs to be air-cooled. The ambient temperature must be 32°F to 104°F (0°C to 40°C). [. . . ] NOTE: Use copper conductors only ­ rated 75°C 2. With the circuit breaker turned off, connect the circuit feed (HOT and NEUTRAL) and controlled circuit (LOAD) wires to the terminal block per the markings provided on the wiring label (as shown in the diagrams on this page). Terminal blocks accept one 14 - 10 AWG wire. Wires should be stripped to ½ inch. Grounding terminal blocks are available in the cabinet for termination of ground wires. Test the circuit for electrical faults by turning on the circuit breaker and checking that the breaker TO LOAD(S) GROUNDING TERMINAL BLOCK AREA FOR MODULE LOCATION LABEL CRESTRON LEFT SIDE WIRING LABEL TERMINAL BLOCK Wiring Diagram of the Terminal Block to the Feed and Load(s) (Right Side Double-wide Enclosures) CLX-1DELV4 1 FEED 4 DIM 120VAC 60 Hz 16A MAX 9A MAX/CKT BYPASS JUMPER N OUT 4 N OUT 3 N OUT 2 N OUT 1 N IN DIM 4 DIM 3 DIM 2 DIM 1 LINE GND NEUTRAL HOT (FROM 15 OR 20 AMP CIRCUIT BREAKER) 3. TO LOAD(S) GROUNDING TERMINAL BLOCK 4. CRESTRON AREA FOR MODULE LOCATION LABEL TERMINAL BLOCK RIGHT SIDE WIRING LABEL 2 · Terminal Block & Module: CLT- & CLX-1DELV4 Installation Guide ­ DOC. 5989A Crestron CLT- & CLX-1DELV4 Module Installation CAUTION: Module contains electrostatic sensitive devices (ESDs); unit must be handled from metal chassis ­ do not touch PC board or components. NOTE: Modules are to be installed after enclosure has been completely wired. Refer to the terminal block installation procedure on page 2 for details. Use the four supplied self-tapping pan Phillips screws (8B x ¼ length) to secure the module to the enclosure. As shown in the wiring diagrams (next column), connect the wires from the module to the terminal block. Each wire exits the module directly in line with, and is the same color as, the terminal to which it should be connected. Wires are pre-stripped to ½ inch. If the module is being installed above another module within the enclosure, attach the supplied module interconnect cable between the two modules. The illustration below depicts the area within a double-wide enclosure where the corners of four modules meet. Terminal Block & Module NOTE: Before the five-position bypass jumper, shown in the illustration, is removed, the Crestron Professional Automation Computer (PAC2), which provides control to the system, should be properly connected and contain a valid program to provide control of the module. Wiring Diagram of the Terminal Block to the Module (Single-wide and Left Side Double-wide Enclosures) BLACK RED 2. WHITE 3. ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3) ENLARGEMENT DETAIL: LOCATION OF FIVE-POSITION BYPASS JUMPER ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPER ON BLACK AND RED SECTION OF TERMINAL BLOCK HAS BEEN REMOVED AFTER LOOSENING ALL SCREWS. JUMPER ON WHITE SECTION REMAINS INSTALLED. NOTE: One wire on the module interconnect cable may be a different color from the rest. The color has no bearing on its orientation during installation. Use Module Interconnect Cable to Wire Module to Module MODULE INTERCONNECT CABLE ATTACHED CONNECTION NOT MADE JUMPER Wiring Diagram of the Terminal Block to the Module (Right Side Double-wide Enclosures) WHITE RED BLACK 4. Turn on the circuit breaker and verify that the green PWR LED on the module lights, the breaker does not trip, and proper loads are energized. Turn off the circuit breaker and remove the fiveposition bypass jumper on the black and red section of the terminal block. The bypass jumper on the white section of the terminal block remains installed. Refer to the figures in the next column for a close-up of the jumpers. ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3) JUMPER 5. ENLARGEMENT DETAIL: LOCATION OF FIVE-POSITION BYPASS JUMPER ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPER ON WHITE SECTION REMAINS INSTALLED. [. . . ] After turning on the last output, press the SETUP button again to turn on all outputs. Press the SETUP button once more to turn off all outputs and LEDs and exit Local Mode. 2. 2. 5. 3. Further Inquiries If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. For assistance in your local time zone, refer to the Crestron website (www. crestron. com) for a listing of Crestron worldwide offices. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLT-1DELV4 CLX-1DELV4

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CLT-1DELV4 CLX-1DELV4 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag