User manual CRESTRON CLW-SW1 SWS1 SLVS1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON CLW-SW1 SWS1 SLVS1. We hope that this CRESTRON CLW-SW1 SWS1 SLVS1 user guide will be useful to you.

Lastmanuals help download the user guide CRESTRON CLW-SW1 SWS1 SLVS1.


Mode d'emploi CRESTRON CLW-SW1 SWS1 SLVS1
Download
Manual abstract: user guide CRESTRON CLW-SW1 SWS1 SLVS1

Detailed instructions for use are in the User's Guide.

[. . . ] CLW-SW1, SWS1, & SLVS1(W/A/B) Introduction Features and Functions The CLW-SW1 (-SW1) is a stand-alone wall box switch that can also act as a Cresnet® device that reports to a Crestron® control processor. The -SW1 includes two isolated, non-polarized Cresnet wires (plus a ground wire) for connecting to a Cresnet system over a twisted pair wire with shield. The CLW-SW1 features a three-position mode selection switch. Refer to "Operation " on page 5 for more information. [. . . ] Installing with power on can result in serious personal injury and damage to the device. NOTE: The -SW1, -SWS1 require a neutral wire for operation. If no neutral is present, contact a licensed electrician for installation, otherwise the device will not work. NOTE: The -SWS1 must be installed in the same wallbox that contains the connections to the load. NOTE: New installations should be checked for short circuits prior to installing the -SW1, -SWS1, or -SLVS1. With power off, close the circuit and restore power. If the load does not work or a breaker trips, check and correct the wiring or fixture (if necessary). Install the -SW1, -SWS1, or -SLVS1 only when the short is no longer present. The warranty is void if the -SW1, -SWS1, or -SLVS1 is installed and operated with a shorted load. When installing a -SW1 or a -SWS1 without a slave, follow the instructions in "Wiring a -SW(S)1 (No Slaves)" below. If wiring a -SWS1 with a -SLVS1, refer to "Wiring a -SWS1 with One or More -SLVS1s" on the next page. Derating Information for General Purpose Fans Part Number -SW1 -SWS1 -SLVS1 No Side Removed 3A 3A One Side Removed 3A 3A No Derating Necessary Two Sides Removed 3A 3A 2. To remove a side section, bend the side section back and forth with a pair of pliers until the section breaks off from the mounting plate. Use a file or sandpaper to remove any excess metal. Prewire for Master Application Each device has two Class 2 low voltage wires (plus a ground wire) that provide a Cresnet connection over shielded twisted-pair to a Crestron control system. These wires are routed to the bottom of the device for connection outside of the wallbox. The low voltage wires are pulled from each device location to the Crestron control system or a Crestron connection block device. Use #22 AWG, twisted, shielded, 2-conductor wire. Wiring can be daisy chained, T-tapped, or home run back to the control system. NOTE: If a -SWS1 is installed without a -SLVS1, the BLUE lead (Slave) should be capped. NOTE: The WHITE (Neutral) connection on the -SLVS1 is optional and is only required for operation of the LED. If the neutral is not available, the white lead should be capped off. Splice the gray wires of the -SWS1 to the Class 2 low voltage wires connected to the Crestron control system or a Crestron connection block device. Push the wires and the splices into a hole in the drywall to provide the necessary separation. Push all power wires back into the wallbox and fasten the devices to their respective wallboxes with the provided screws. [. . . ] Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. Products may be returned for credit, exchange, or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N. J. or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLW-SW1 SWS1 SLVS1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CLW-SW1 SWS1 SLVS1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag