[. . . ] Crestron IM-WCVI iMedia Wall Plate Computer Center with Video Interface Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at:
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON
All brand names, product names and trademarks are the property of their respective owners. ©2006 Crestron Electronics, Inc.
Crestron IM-WCVI
iMedia Wall Plate Computer Center with Video Interface
Contents
iMedia Wall Plate Computer Center with Video Interface: IM-WCVI 1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Female RJ-45 port to connect to IM-WCVP over CresCAT-IM wire or other high-quality CAT5 wire (40 feet maximum). (1) Female DB15HD connector is used for connecting a computer's RGB video output to the display device. The following table lists pin assignments:
PIN 1 2 3 4 5 6 7 8 FUNCTION Red Video Green Video Blue Video Reserved Ground Red Ground Green Ground Blue Ground PIN 9 10 11 12 13 14 15 FUNCTION No Connect Ground No Connect Monitor Sense 1 Horizontal Sync Vertical Sync Monitor Sense 2
4
TO IM-WCVP CONTROL CENTER
5
PC
6
AUDIO (PC)
(1) 3. 5mm female mini-jack connects to audio output of PC.
7
GROUND WIRE
Connect the flying lead to earth ground.
Operations & Installation Guide DOC. 6488
iMedia Wall Plate Interface: IM-WCVI · 5
iMedia Wall Plate Computer Center with Video Interface
Crestron IM-WCVI
Industry Compliance
As of the date of manufacture, the IM-WCVI has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling.
NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
6 · iMedia Wall Plate Interface: IM-WCVI
Operations & Installation Guide DOC. 6488
Crestron IM-WCVI
iMedia Wall Plate Computer Center with Video Interface
Setup
Network Wiring
When wiring the network, consider the following: · · Use Crestron Certified Wire. Use Crestron power supplies for Crestron equipment.
IM Wiring
Using a proprietary signal routing solution, RGBHV, audio, power and control signals are all transported using a single cable solution called iMedia. The iMedia transport system port is capable of managing computer RGB and audio signals simultaneously through one CresCAT-IM cable, simplifying installations. Routing CresCAT-IM cable (low-skew CAT5e) is less expensive and a much simpler solution for the wiring of iMedia systems than routing multi-colored, multiconductor coax cable. All Crestron products using the iMedia transport system are capable of sending and receiving iMedia signals via CresCAT-IM cable. Installation of any iMedia device is as simple as installing one iMedia cable from output to input. Installations are affordable, and fast.
Quantity and Packaging
· · · CRESCAT-IM-P-B500 is a low-skew CAT5e cable, plenum-rated, available in a 500 foot box CRESCAT-IM-P-SP500is a low-skew CAT5e cable, plenum-rated, available in a 500 foot spool CRESCAT-IM-P-SP1000 is a low-skew CAT5e cable, plenum-rated, available is a 1000 foot spool
For more information on CresCAT and other wire products, visit the Crestron website (www. crestron. com/features/wire).
Pin Assignments
The pin assignment is based on the EIA/TIA 568B RJ-45 Jack standard. Power is supplied to the IM transmitters via the audio circuit. To determine which pin is number 1, hold the cable so that the end of the eight pin modular jack is facing you, with clip down and copper side up. When looking down at the copper connections, pin 1 is on the far right.
Operations & Installation Guide DOC. Required Tools: · Phillips screwdriver
Mounting Parts Supplied with the IM-WCVI
PART DESCRIPTION Screw #6-32 x 1 in, Flat Head, Phillips
Installation in a Double-Gang Electrical Box
QUANTITY 4
NOTE: Run iMedia wire through the top or bottom of the electrical box.
#6-32 x 1 in. Depth, Double-Gang Electrical Box
Operations & Installation Guide DOC. 6488
iMedia Wall Plate Interface: IM-WCVI · 9
iMedia Wall Plate Computer Center with Video Interface Hardware Hookup
Ventilation
Crestron IM-WCVI
To prevent overheating, do not operate this product in an area that exceeds the environmental temperature range listed in the table of specifications. Consideration must be given if installed in a closed or multi-unit rack assembly since the operating ambient temperature of the rack environment may be greater than the room ambient. Contact with thermal insulating materials should be avoided on all sides of the unit. Make the necessary connections as called out in the illustration that follows this paragraph. Turn on the system only after all connections have been made.
Hardware Connections for the IM-WCVI (Rear)
Connect the Device
TO IM-RXV RECEIVER: CONNECT TO IMEDIA RECEIVER
TO IM-WCVP: CRESCAT-IM CONNECTION TO IM-WCVP
GROUND
NOTE: For optimum performance, Crestron strongly recommends using CRESCAT-IM cable, available from Crestron. [. . . ] Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N. J. or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee, plus shipping costs, on any products returned with an RMA. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON IO IM-WCVI Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON IO IM-WCVI will begin.