User manual CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF. We hope that this CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF user guide will be useful to you.

Lastmanuals help download the user guide CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF.


Mode d'emploi CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF
Download
Manual abstract: user guide CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF

Detailed instructions for use are in the User's Guide.

[. . . ] infiNETTM DIMMERS Introduction Features and Functions The CLW-DIM1RF (-DIM1RF) and CLW-DIM4RF (-DIM4RF) are stand-alone wall box dimmers that can also act as wireless infiNETTM devices that report to a Crestron® control processor through an infiNET gateway such as the Crestron C2N-MNETGW. The -DIM1RF and -DIM4RF have three preset lighting levels that can be adjusted. For more information, refer to the latest version of the infiNET Dimmers Operations Guide (Doc. 6396) which is available from the Crestron website (www. crestron. com/manuals). [. . . ] Operation of a low voltage circuit with all lamps inoperative or removed may result in current flow in excess of normal levels. To avoid transformer overheating and premature transformer failure, Crestron recommends the following: Do not operate low voltage circuits without operative lamps in place. Replace burned-out lamps as quickly as possible. Use transformers that incorporate thermal protection or fuse transformer primary windings to prevent transformer failure due to overcurrent. DO NOT REMOVE OUTER SECTIONS Inner Sections of Multiganged Switches (CLW-DIM4RF shown) REMOVE INNER SECTIONS · RUN SET OFF RUN SET OFF · · The load capacity must also be derated. The following charts provide derating information for various applications. Derating Information for Incandescent and TungstenHalogen Applications Part Number -DIM1RF/ -DIM4RF -DIMS1RF/ -DIMS4RF -SLVD1RF No Side Removed 1000W 1000W One Side Removed 700W 700W No Derating Necessary Two Sides Removed 550W 550W Derating Information for Magnetic Low Voltage Applications* Part Number -DIM1RF/ -DIM4RF -DIMS1RF/ -DIMS4RF -SLVD1RF * No Side Removed 1000VA/ 750W 1000VA/ 750W One Side Removed 700VA/500W 700VA/500W No Derating Necessary Two Sides Removed 550VA/ 400W 550VA/ 400W Multigang Installations In multigang installations, several controls are grouped horizontally in one wallbox. For a smooth appearance, one-piece multigang faceplates (not supplied) can be installed. When combining controls in a wallbox, remove inner side sections prior to wiring as shown in the following diagram. VA ratings are for input power to the transformer. If you do not know the input power requirement of the transformer, use the bulb's wattage rating to determine proper rating. 2. To remove a side section, bend the side section back and forth with a pair of pliers until the section breaks off from the mounting plate. Use a file or sandpaper to remove any excess metal. 4 · infiNETTM Wall Box Dimmer : CLW-DIM1/4RF, DIMS1/4RF, & SLVD1RF Installation Guide ­ DOC. 6292A infiNETTM DIMMERS 3. Installation WARNING: Turn off power at the circuit breaker. Installing with power on can result in serious personal injury and damage to the device. NOTE: The -DIM1RF, -DIM4RF, -DIMS1RF, -DIMS4RF, and -SLVD1RF require a neutral wire in the wallbox for operation. If no neutral is present, contact a licensed electrician for installation or refer to the alternative wiring diagrams described in "Appendix: Wiring Diagrams" on page 8. NOTE: The -DIMS1RF and -DIMS4RF must be installed in the same wallbox that contains the connections to the load. NOTE: New installations should be checked for short circuits prior to installing an infiNET dimmer. Wire the dimmer as shown in Figure 1 on page 8. NOTE: The RED (Load) and BLACK (Hot) wires are #14 AWG. The BLUE (Slave) and WHITE (Neutral) wires are #18 AWG. NOTE: Since the -DIMS1RF or -DIMS4RF is installed without a -SLVD1RF, the BLUE lead (Slave) should be capped. Alternative Wiring For situations where a neutral is not present or other scenarios that may be encountered during installation, refer to the "Stand-Alone Installations" section of "Appendix: Wiring Diagrams" on page 8. 4. 6292A infiNETTM Wall Box Dimmer: CLW-DIM1/4RF, DIMS1/4RF, & SLVD1RF · 5 infiNETTM DIMMERS Testing a -SLVD1RF Testing NOTE: The device may be warm to the touch during operation. Test the installation by setting the dimmer's mode selection switch (shown in the following diagrams) to the "RUN" position and perform either of the following steps (depending on the dimmer model). Parts of CLW-DIM1RF and -DIMS1RF Tap the top of the button to turn on the load. [. . . ] Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supercedes all previous warranties. Trademark Information All brand names, product names, and trademarks are the sole property of their respective owners. Windows is a registered trademark of Microsoft Corporation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON IW CLW-DIM1RF 4RF DIMS1RF 4RF SLVD1RF will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag