User manual CRESTRON LEPB-1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON LEPB-1. We hope that this CRESTRON LEPB-1 user guide will be useful to you.

Lastmanuals help download the user guide CRESTRON LEPB-1.


Mode d'emploi CRESTRON LEPB-1
Download
Manual abstract: user guide CRESTRON LEPB-1

Detailed instructions for use are in the User's Guide.

[. . . ] Figure 2: End View Power Extender Power Extender Wallplate TOP Raised Cover Mounting Screws (4 Places) TOP Power Extender Power Extender Wallplate Figure 3: Front View Figure 4: Front View Spacing TOP TOP INSTALLATION INSTRUCTIONS FCC COMPLIANCE STATEMENT CONTROL NEUTRAL NEUTRAL DI-000-PE100-00A-Pilot This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. SWITCH HOT LOAD HOT Green LED 4-1/2" (11. 4 cm) Minimum Trim Adjustment TOP LIMITED 2 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date. [. . . ] WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO/ALR OR CU/AL. NOTE: The Power Extender must be installed in a 1900 Box with Raised Cover or a properly grounded metal 2-gang wall box, 3. 5" (8. 9 cm) deep (refer to Figure 1A, 1B, 2A, and 2B). Depending on the application and the number of connections, more space may be needed. If so, use an appropriate size box or box extension. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKERS OR FUSES AND TEST THAT POWER IS OFF BEFORE WIRING!MORE THAN ONE CIRCUIT BREAKER CAN POWER THIS DEVICE. DISCONNECT "ALL" POWER SOURCES BEFORE SERVICING CONTROL. Remove 1/2" (1. 3 cm) of insulation from each circuit conductor in wall box. Make sure that ends of conductors are straight. Connect lead wires per appropriate WIRING DIAGRAM and FIGURE 2 as follows: All connections to the output terminals should be made using #12 AWG wire. Each power terminal can accept up to two(2) #12 wires. The recommended installation torque is 9. 0 in. -lbs. Carefully position all wires to provide room in outlet box for Power Extender. All Power Extenders must have 4-1/2" spacing above and below each unit for proper ventilation and heat dissipation (refer to Figure 4). Line voltage wiring should be at least 6 ft. away from sound or electronic equipment wiring. Mount Power Extender to wall box with "TOP" facing up as follows (refer to Figure 3). For Wall Box Mounting: Refer to Figure 1A. For Panel Mounting (not shown), Proceed as follows: 4-1/2" (11. 4 cm) Minimum a. The enclosure must be in accordance with all local and national electrical codes. [. . . ] The PE100-1 has an air gap relay built in, therefore, the load will be disconnected by an air gap when the dimmer is OFF or the air gap control on the dimmer is activated. Wiring Diagram 1A: Single Feed Wiring Application w/Controller Hot (Black) (120VAC) Wiring Diagram 1B: Single Feed Wiring Application w/Dimmer Used if Dimmer/Switch has Neutral connection (Load) Hot (Black) (120VAC) (Load) Single Feed Wiring: Line Hot can be controlled by one circuit breaker as long as the total load does not exceed the rating of the circuit breakers. D3206/08 Controller/Dimmer Neutral Line Load Power Extender Green Ground Single Feed Wiring: Line Hot can be controlled by one circuit breaker as long as the total load does not exceed the rating of the circuit breakers. Dimmer White Black Load CONTROL NEUTRAL NEUTRAL SWITCH HOT CONTROL NEUTRAL NEUTRAL LOAD Power Extender LOAD HOT SWITCH HOT LOAD HOT Green Ground LOAD Neutral (White) Neutral (White) TROUBLESHOOTING · The Power Extender is not powered - Circuit breaker is OFF. - Power wires are not connected properly. · The load does not turn ON, but the Power Extender is powered - The dimmer is OFF. - The dimmer air gap switch is activated. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON LEPB-1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON LEPB-1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag