User manual CRESTRON LEPB-4

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON LEPB-4. We hope that this CRESTRON LEPB-4 user guide will be useful to you.

Lastmanuals help download the user guide CRESTRON LEPB-4.


Mode d'emploi CRESTRON LEPB-4
Download
Manual abstract: user guide CRESTRON LEPB-4

Detailed instructions for use are in the User's Guide.

[. . . ] The Power Extender has wiring for connection to the dimmer it works with, its internal power supply, the load, and the 0-10V dimming signal. Power must be provided to the PE300 for it to operate. The power connection can be 120V or 277V AC, and can be from the same phase as the dimmer or a different one. Care must be taken when wiring the dimmer to the power extender. [. . . ] To operate the PE300, the dimmer must be operated as follows: ON: Turn OFF: DIM: Air Gap: Turn ON the dimmer. Adjust the dimmer DIM level. BRIGHTEN: Adjust the dimmer BRIGHTNESS level. Activating the air gap on the dimmer will cause the PE300 to turn its controlled Load OFF. CAUTION: The Power Extender will still remain powered, but it will not activate the load. The PE300 has an air gap relay built in, therefore, the ballasts will be disconnected by an air gap when the dimmer is OFF or the air gap control on the dimmer is activated. Table 1 ­ LED Indicators LED Meaning Physical Location Color State Relay LED 1 Red If load is connected, LED ON Power LED 2 Green If there is internal power, LED ON For more information go to www. leviton. com INSTALLATION INSTRUCTIONS DI-000-PE300-00A OUTPUTS Dimming Control: The GRAY and VIOLET wires provide a control voltage (current sink) that DIMS the ballasts. The control voltage varies between 0. 6 - 10VDC. WIRING All wires type: 105°C AWM, 600V Table 2 ­ Wiring Designators Signal Name Color Black White Green Red White/Red 2 Blue Violet Gray Violet Gray Gauge 18AWG 18AWG 12AWG 18AWG 18AWG 12AWG 18AWG 18AWG 18 AWG 18 AWG From bottom opening Line (for power supply) Neutral (for power supply) Ground Dimmer input Dimmer return Relay contacts ­ Load Dim (To Ballast) Return (To Ballast) WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS. WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN. BOTH LIGHTING FIXTURE AND CONTROLLER MUST BE GROUNDED. DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING LAMPS. TO BE USED FOR DIMMING ONLY WITH 0-10V DIMMING BALLASTS. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO/ALR OR CU/AL. NOTE: The Power Pack must be installed in a properly grounded metal 4" (10. 2 cm) outlet box. Depending on the application and the number of connections, more space may be needed. If so, use an appropriate size box or box extension. There are two wiring ports on the Power Pack, one for high-voltage (Line) wires and one for low-voltage wires. The high-voltage wires exit out of the bottom, and the low-voltage wires exit out of the side. Refer to Table 2 for wire designations. From side opening Dim (To Ballast) Return (To Ballast) LIMITED 2 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date. Leviton's only obligation is to correct such defects by repair or replacement, at its option, if within such two year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co. , Inc. , Att: Quality Assurance Department, 5925 Little Neck Parkway, Little Neck, New York 11362-2591 (In Canada send to Leviton Mfg. of Canada Ltd. , 165 Hymus Blvd. , Point Claire, (Quebec), Canada H9R 1E9). [. . . ] Low-Voltage Wiring (side wiring port): Connect lead wires per WIRING DIAGRAM as follows: Using low-voltage wires exiting the Power Pack, twist strands tightly together and, with lowvoltage device conductors, push firmly into appropriate wire connector. Screw connectors on clockwise making sure that no bare conductor shows below the wire connectors. Secure each connector with electrical tape. Figure 1 ­ Controls · The Power Extender is not powered (Green LED OFF) - Circuit breaker is OFF. - Power wires are not connected properly. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON LEPB-4

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON LEPB-4 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag