[. . . ] Crestron QM-WMIC Wall Plate Media Center Microphone Input Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at:
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON
All brand names, product names and trademarks are the property of their respective owners. ©2003 Crestron Electronics, Inc.
Crestron QM-WMIC
Wall Plate Media Center Microphone Input
Contents
Wall Plate Media Center Microphone Input: QM-WMIC 1
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Industry Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Programming Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Programming with Crestron SystemBuilder. . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Programming with SIMPL Windows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Programming with VisionTools Pro-e. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Example Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Adjusting the QM-WMIC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Setting Microphone Gain. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Setting the Gating Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Problem Solving. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Further Inquiries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Future Updates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Return and Warranty Policies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Merchandise Returns / Repair Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 CRESTRON Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Operations & Installation Guide - DOC. 6245
Contents · i
Crestron QM-WMIC
Wall Plate Media Center Microphone Input
Wall Plate Media Center Microphone Input: QM-WMIC
Introduction
Features and Functions
The Wall Plate Media Center Microphone Input (QM-WMIC) is an optional part of the Crestron MediaManagerTM line of network devices, room control systems, and signal routing solutions. [. . . ] Doubleclick Slot 2 of the QM-WMC symbol to view the details of the QM-WMIC symbol. QM-WMIC Symbol in Programming Manager Programming Manager is where programmers "program" a Crestron control system by assigning signals to symbols. The following describes the QM-WMIC symbol in the SIMPL Windows Programming Manager. NOTE: Many of the signals in the QM-WMIC symbol are used to adjust operating parameters such as gain, gating/gating level, attack time and decay time. For definitions and information on the effects of adjusting these parameters, refer to "Adjusting the QM-WMIC" on page 18. QM-WMIC symbol in SIMPL Windows Programming Manager
The following tables list the symbol's input and output signals, respectively, and their functional descriptions.
14 · Wall Plate Media Center Microphone Input: QM-WMIC
Operations & Installation Guide - DOC. 6245
Crestron QM-WMIC
Wall Plate Media Center Microphone Input
QM-WMIC Digital Input Signal Descriptions INPUT
Mic1Mute Mic2Mute Mic1GatingEnable Mic2GatingEnable PhantomEnable
DESCRIPTION
Mutes the input signal from Mic 1 when high Mutes the input signal from Mic 2 when high Enables automatic gating on Mic 1 when high Enables automatic gating on Mic 2 when high Enables phantom power for both microphone inputs when high
NOTE: Phantom power is applied to the XLR connectors of both microphone inputs. It cannot be switched on an individual microphone input. QM-WMIC Analog Input Signal Descriptions INPUT
Mic1GatingLevel Mic2GatingLevel Mic1Gain Mic2Gain AttackTime DecayTime
DESCRIPTION
Specifies gating level for Mic 1 (0 to 100%) Specifies gating level for Mic 2 (0 to 100%) Specifies gain level for Mic 1 (0 to 100%) Specifies gain level for Mic 2 (0 to 100%) Specifies attack time (10 to 100 ms) Specifies decay time (10 to 5000 ms)
NOTE: AttackTime and DecayTime are applied to both microphone inputs. QM-WMIC Digital Output Signal Descriptions OUTPUT
Mic1Mute-F Mic2Mute-F Mic1GatingEnable-F Mic2GatingEnable-F Mic1Gate Mic1Nominal
DESCRIPTION
Indicates Mic 1 is muted Indicates Mic 2 is muted Indicates automatic gating on Mic 1 enabled Indicates automatic gating on Mic 2 enabled Indicates Mic 1 gating level has been reached Indicates Mic 1 at nominal level
(continued on next page)
Operations & Installation Guide - DOC. 6245
Wall Plate Media Center Microphone Input: QM-WMIC · 15
Wall Plate Media Center Microphone Input
Crestron QM-WMIC
QM-WMIC Digital Output Signal Descriptions (continued) OUTPUT
Mic1Clip Mic2Gate Mic2Nominal Mic2Clip PhantomEnable-F
DESCRIPTION
Indicates Mic 1 signal is at 6 dB below input clip level Indicates Mic 2 gating level has been reached Indicates Mic 2 at nominal level Indicates Mic 2 signal is at 6 dB below input clip level Indicates when phantom power is enabled.
NOTE: The gating level indicators will still function even if the gating function is not enabled.
NOTE: Nominal indication is reported at 20 dB below input clip level. Clip indication is reported at 6 dB below input clip level. QM-WMIC Analog Output Signal Descriptions OUTPUT
Mic1GatingLevel-F Mic2GatingLevel-F Mic1Gain-F Mic2Gain-F AttackTime-F DecayTime-F
DESCRIPTION
Gating level feedback for Mic 1 Gating level feedback for Mic 2 Gain level feedback for Mic 1 Gain level feedback for Mic 2 Attack time setting feedback Decay time setting feedback
NOTE: Returned values match values that were selected for the GatingLevel, Gain, AttackTime and DecayTime inputs.
16 · Wall Plate Media Center Microphone Input: QM-WMIC
Operations & Installation Guide - DOC. 6245
Crestron QM-WMIC
Wall Plate Media Center Microphone Input
Programming with VisionTools Pro-e
Touchpanel screens can be created in VT Pro-e to allow configuration of phantom power, gain levels, gating levels, attack times, and decay times. Digital Media Tools software already has these controls built in. Refer to the section "Adjusting the QM-WMIC" on page 18 for instructions.
Example Program
An example program for the wall plate is available from the Crestron FTP site (ftp://ftp. crestron. com/Examples). Search for the file named QM-WMC_QM-WMIC. ZIP.
Operations & Installation Guide - DOC. 6245
Wall Plate Media Center Microphone Input: QM-WMIC · 17
Wall Plate Media Center Microphone Input
Crestron QM-WMIC
Adjusting the QM-WMIC
Once a QM-WMIC is installed and configured, settings for gain, gating level, attack time, and decay time must be set using the Realtime Mode in Digital Media Tools (version 3. 00. 00 or later). Digital Media Tools software can be started from the SystemBuilder application. NOTE: Crestron recommends that you use the latest software to take advantage of the most recently released features. The latest software is available from the Downloads | Software Updates section of the Crestron website (www. crestron. com).
Definitions
The QM-WMIC allows for adjustments to be made to microphone input signals. Following are definitions of terms that are commonly used when making adjustments to the QM-WMIC. [. . . ] Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee, plus shipping costs, on any products returned with an RMA. Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser.
2.
3.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON QM-WMIC Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON QM-WMIC will begin.