User manual CROWN POWER-TECH 1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CROWN POWER-TECH 1. We hope that this CROWN POWER-TECH 1 user guide will be useful to you.

Lastmanuals help download the user guide CROWN POWER-TECH 1.


Mode d'emploi CROWN POWER-TECH 1
Download
Manual abstract: user guide CROWN POWER-TECH 1

Detailed instructions for use are in the User's Guide.

[. . . ] POWER-TECH TM Models: Power-Tech 1, 2 & 3 ® Some models may be exported under the name Amcron. © 2000 by Crown International, Inc. , P. O. Box 1000, Elkhart, Indiana 46515-1000 U. S. A. Power-Tech amplifiers are produced by the Professional Audio Unit of Crown International, ® Inc. Trademark Notice: Power-TechTM is a trademark and Amcron, ® Crown, IOC ® and ODEP ® are registered trademarks of Crown International, Inc. [. . . ] Limiting occurs well above 20 kHz, so there is no audible affect on performance. This approach protects the amplifier from radio frequencies and can even protect some sensitive loads (including some tweeters). 3. 3. 3 Drive Protection The drive protection system temporarily removes output drive to protect the amplifier and its loads. Drive protection can be activated in two situations. First, if dangerous subsonic frequencies or direct current (DC) is detected in the amplifier's output, the unit will activate its DC/low-frequency protection circuitry which puts the amplifier in drive protection mode. This protects the loads and prevents oscillations. The unit resumes normal operation as soon as the amplifier no longer detects dangerous output. Although it is extremely unlikely that you will ever activate the amplifier's DC/low-frequency protection system, improper source materials like subsonic square waves or input overloads that excessively clip the input signal can activate this system. 3. 2 Indicators When lit, the amber enable indicator shows that the amplifier has been turned on. It is driven only by the lowvoltage power supply and does not indicate the status of the high-voltage supplies. The signal/IOC indicators flash green in sync with the audio input signal, and flash yellow if the input waveform differs from the output by more than 0. 05%. IOC reports any distortion over 0. 05% introduced by the amplifier including harmonic distortion, intermodulation distortion and clipping distortion. Reference Manual Page 9 Power-Tech Series Power Amplifiers The amplifier's fault protection system will put the amplifier in drive protection mode in rare situations where heavy common-mode current is detected in the output. The unit should never output heavy commonmode current unless its circuitry is damaged. Activating drive protection helps prevent further damage. 3. 3. 4 Transformer Thermal Protection All Power-Tech amplifiers have transformer thermal protection. This protection circuitry is activated in unusual situations where the unit's transformer temperature rises to unsafe levels. Under these abnormal conditions, the unit removes power to the highvoltage transformer. The fan will continue to run in all units except those with 220/240 VAC transformers. The amplifier will return to normal after it cools to a safe temperature. It is very unlikely that your Power-Tech amplifier will ever activate transformer thermal protection as long as it is operated within rated conditions. Your amplifier is designed to keep working under conditions where other amplifiers would fail. But even when you exceed the limits of a Power-Tech amplifier, it still protects itself-- and your investment--from damage. 3. 3. 5 Fuses and Circuit Breakers Your amplifier's low-voltage power supply is protected by an internal fuse, and its high-voltage power supplies are protected by a circuit breaker. [. . . ] 6. 2. 1 Service at a North American Service Center This method usually saves the most time and effort. Simply present your bill of sale along with the defective unit to an authorized service center to obtain service. They will handle the necessary paperwork and repair. Remember to transport the unit in the original factory pack. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CROWN POWER-TECH 1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CROWN POWER-TECH 1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag