User manual CUE SENSORCUE-W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CUE SENSORCUE-W. We hope that this CUE SENSORCUE-W user guide will be useful to you.

Lastmanuals help download the user guide CUE SENSORCUE-W.


Mode d'emploi CUE SENSORCUE-W
Download
Manual abstract: user guide CUE SENSORCUE-W

Detailed instructions for use are in the User's Guide.

[. . . ] 11 Software and Firmware License. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 User Manual sensorCUE-W www. cuesystem. com Page 3 of 14 1. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . sensorCUE-W is a temperature and daylight sensor for indoor installation compatible with ABB Time or Element design series. The temperature sensor can be used for temperature monitoring and heating control. [. . . ] SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 ADDRESS 1 2 3 4 5 6 7 8 9 . . . 126 127 Function ADDRESS bit 0 ADDRESS bit 1 ADDRESS bit 2 ADDRESS bit 3 ADDRESS bit 4 ADDRESS bit 5 ADDRESS bit 6 Not used SW1 ON OFF ON OFF ON OFF ON OFF ON . . . OFF ON SW2 OFF ON ON OFF OFF ON ON OFF OFF . . . ON ON SW3 OFF OFF OFF ON ON ON ON OFF OFF . . . ON ON SW4 OFF OFF OFF OFF OFF OFF OFF ON ON . . . ON ON SW5 OFF OFF OFF OFF OFF OFF OFF OFF OFF . . . ON ON Address bit's weight 1 2 4 8 16 32 64 Not used SW6 OFF OFF OFF OFF OFF OFF OFF OFF OFF . . . ON ON SW7 OFF OFF OFF OFF OFF OFF OFF OFF OFF . . . ON ON User Manual sensorCUE-W www. cuesystem. com Page 7 of 14 5. Programming The standard command for reading out the data from sensorCUE-W is: RemoteVariableGet (reference as Word, paneladdress As Byte) as Word The reference allows to identify which measured value should be read while the paneladdress identifies which sensorCUE unit is to answer. The following reference values are supported: · Reference = 0 sensorCUE firmware version · Reference = 1 temperature value · Reference = 2 lighting level value Reference = 0 sensorCUE-W firmware version Response value is in range 0 - 65535 Example: Fw = RemoteVariableGet (0, 34) This command has assigned the firmware version number of sensorCUE-W (with the address 34) to the Fw variable. Reference = 1 temperature value The temperature is measured with a 12-bit resolution sensor. It covers the measuring range from +50 °C to -20 °C The temperature value is encoded into a 16-bit response value according to the following rules: Response value bit weight BIT 15 S 14 S 13 S 12 S 11 S 10 26 9 25 8 24 7 23 6 22 5 21 4 20 3 2-1 2 2-2 1 2-3 0 2-4 S means sign. S=0 for positive and S=1 for negative values. User Manual sensorCUE-W www. cuesystem. com Page 8 of 14 Temperature ­Response data relationship: TEMPERATURE +25. 0625°C +10. 125°C +0. 5°C +0°C -0. 5°C -10. 125°C RESPONSE VALUE (binary) 0000 0001 1001 0001 0000 0000 1010 0010 0000 0000 0000 1000 0000 0000 0000 0000 1111 1111 1111 1000 1111 1111 0101 1110 RESPONSE VALUE (hex) 0191H 00A2H 0008H 0000H FFF8H FF5EH Example: T = RemoteVariableGet (1, 68) This command has assigned the temperature from sensorCUE-W (with the address 68) to the T variable. Reference = 2 the lighting level value The expected response value range is ( 1 - 30000). The lowest values mean the highest lighting levels and the highest values mean dark. The typical expected return values are as follows: For straight full light the return values are below 100 For bright room the return values are about 700-800 For dark room the return values are about 3500-5000 Example: Light = RemoteVariableGet (2, 47) This command has assigned the lighting level from sensorCUE-W (with the address 47) to the Light variable. User Manual sensorCUE-W www. cuesystem. com Page 9 of 14 6. Program module for sensorCUE For easier programming you can use the module sensorCUE. csm. You can find it on the CUE Application CD in folder XPL Drivers and Modules. This module is also compatible with sensorCUE-W. This module has two functions: Public Function Temperature (PanelAddress As Word, ByRef TemperatureAsText As String) As Integer GetTemperature returns current temperature measured in 1/10 degrees of Celsius as integer value (it allows negative values). Returned values are -200 (-20 °C) to 500 (+50 °C). The first parameter is the panel address of sensorCUE-W, the second parameter is string, where temperature value will be stored as string ("-20. 0" to "+50. 0") Example: Declarations: Public TemperatureInt As Integer Public TemperatureString As String *10 Program: TemperatureInt = GetTemperature(38, TemperatureString) This command has assigned the temperature from sensorCUE-W (with the address 38) to the TemperatureInt variable. [. . . ] You may make one (1) copy of the Software for archival purposes only. You may use this Software only in connection with CUE hardware. You must have acquired the Software directly in connection with the purchase of CUE hardware from CUE or from a CUE approved reseller for this license to be effective. If You have purchased a Site License, You may complete only the number of installations specified in the License Agreement accompanying the Software. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CUE SENSORCUE-W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CUE SENSORCUE-W will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag