User manual CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 12 MODEL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 12 MODEL. We hope that this CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 12 MODEL user guide will be useful to you.

Lastmanuals help download the user guide CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 12 MODEL.


Mode d'emploi CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 12 MODEL
Download
Manual abstract: user guide CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 12 MODEL

Detailed instructions for use are in the User's Guide.

[. . . ] Culligan® Advanced Platinum Plus Series Automatic Water Conditioner Owners Guide Thank You And Welcome To Your New World Of Better Living With Culligan Water. The Culligan Advanced Platinum Plus Series Water Softeners with Soft-Minder® Meter and Aqua-Sensor® sensing device are tested and certified by WQA against NSF/ANSI Standard 44 for the effective reduction of hardness (calcium and magnesium), barium and radium 226/228 as verified and substantiated by test data. For installations in Massachusetts, Massachusetts Plumbing Code 248 CMR shall be adhered to. Consult your licensed plumber for installation of this system. This system and its installation must comply with state and local regulations. [. . . ] Once the desired value is displayed, this value can be accepted by pressing the "CHECK MARK" button. Manual Mode Regen tonite Manual Mode By selecting the "REGEN TONITE" value the softener will regenerate that night at 2:00 AM (or at the preset regeneration time) Regen now By selecting the "REGEN NOW" value the softener will begin regeneration immediately. Press the "CANCEL" button to return to the "home" screen. 30 Regeneration There are several conditions that will cause the control to trip a regeneration. The "REGEN TONITE" will be displayed when the control has signaled for a regeneration. The "REGENERATING" will be displayed while the control is in regeneration. The following are conditions that will call for regeneration: 1. When the Soft-Minder ® meter has recorded the passage of a predetermined number of gallons. When the Aqua-Sensor ® Probe senses the hardness in the Cullex Media. At the preset time, when the number of days without a regeneration is equal to the Timeclock Backup setting. At the preset time, when the "REGEN TONITE" is pressed. "REGEN TONITE" will be displayed. Immediately, when the "REGEN NOW" button is pressed. "REGENERATING" will be displayed. Immediately, if power to the unit has been off for more than 3 hours and time of day has been restored. Final Start-up (Cont. ) Recommended Meter Start-Up Procedure · · · · · · · · · · · · Close the main water supply valve. Set the Cul-Flo-Valv ® to the bypass position. Ensure that all faucets at the installation site are closed. Direct the drain line discharge into a bucket where flow can be observed. Plug the transformer into a 120 Volt, 60 Hz, single-phase receptacle. Initiate an immediate regeneration to move the control into the backwash position. Refer to the section on manual cycling for information on cycling the control through its positions. When in the backwash position, slowly shift the bypass to the soft water position until water flows. Allow the tank to fill slowly until water flows from the drain line. When flow to drain is established, open the bypass fully. Watch the drain line discharge for signs of resin. [. . . ] The GBE circuit board, The control valve body, excluding internal parts. The salt storage container, brine valve and all its component parts For the LIFETIME of the The Quadra-HullTM conditioner tank original consumer purchaser and the Cullex® resin If a part described above is found defective within the specified period, you should notify your independently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. You pay only freight from our factory and local dealer charges. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 12 MODEL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CULLIGAN ADVANCED PLATINUM PLUS SERIES AUTOMATIC WATER 12 MODEL will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag