[. . . ] Read also the operation manual attached to the indoor unit and to the outdoor unit for safe usage of the system and maintenance. [1] 1-1 1 3 6 4 hr. ON OFF 8 1-2 H M L DOWN UP FAN 10 ON OFF TEMP H M L TIME C 11 DOWN C UP 2 5 hr. 9 FAN 13 12 15 14 16 RESERVE CANCEL hr. TEST TIMER MODE SWING hr. 7 TEST TEST 17 1 COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH 18 20 21 19 24 23 25 22 1-3 2 [2] 3 C ON OFF ON OFF DOWN UP FAN 3 TEMP TIME 26 C UP FAN DOWN RESERVE CANCEL TIMER MODE SWING 4 1 5 /TEST 3 1 3 4-1 C ON OFF ON OFF DOWN UP FAN 3 TEMP TIME 26 1 C UP FAN DOWN RESERVE CANCEL 4 1 TIMER MODE 1 4-2 SWING 5 /TEST 1 4-3 4 [3] ON OFF ON OFF ON OFF TEMP TEMP TIME TIME UPUP DOWN DOWN FAN FAN RESERVE CANCEL RESERVE CANCEL TIMER TIMER MODE MODE SWING SWING 2244 1 TEMP TIME UP FAN DOWN 35 1 RESERVE CANCEL TIMER 1 1 3 3 MODE SWING 2 4 /TEST /TEST /TEST 5 6 ON OFF TEMP TIME 2 C ON ON OFF OFF ON OFF TEMP TEMP TIMETIME C UP FAN DOWN C 2 3 4 1 1 24 6 TEMP TIME UP UP UP DOWN DOWN FAN FAN RESERVE CANCEL RESERVE CANCEL CODE FAN DOWN 24 6 RESERVE CANCEL hr. TIMER TIMER TIMER MODE MODE SWING SWING hr. MODE SWING ( ) UNIT NO. RESERVE CANCEL TIMER MODE SWING 1 /TEST /TEST /TEST 35 7 /TEST 1 7 8 9 [4] CONTENTS PRIOR TO USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [1] ILLUSTRATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [2] 1 SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . 1 2 NAMES AND FUNCTIONS OF THE OPERATING SECTION. . . . . . . . . . . . . . . . . . . . [. . . ] When using the wireless remote controller, do not put a strong light beam or install an inverter fluorescent lamp near the receiving section on the main unit. Watch your steps at the time of air filter cleaning or inspection. High-place work is required, to which utmost attention must be paid. If the scaffold is unstable, you may fall or topple down, thus causing injury. 7 8 9 10 2. NAMES AND FUNCTIONS OF THE OPERATING SECTION (Fig. 1, 2) DISPLAY " " (SIGNAL TRANSMISSION) 1 This lights up when a signal is being transmitted. DISPLAY " "" "" "" " " " (OPERATION MODE) 2 This display shows the current OPERATION MODE. For straight cooling type, " " (Auto) and " are not installed. H M L 11 12 13 14 15 " (Heating) DISPLAY " " 3 (SET TEMPERATURE) This display shows the set temperature. C 16 DISPLAY " hr. (PROGRAMMED TIME) 4 This display shows PROGRAMMED TIME of the system start or stop. 5 6 DISPLAY " " (AIR FLOW FLAP) Refer to page 9. DISPLAY " " " " (FAN SPEED) The display shows the set fan speed. 17 18 TEST " (INSPECTION/ DISPLAY " TEST OPERATION) When the INSPECTION/TEST OPERATION BUTTON is pressed, the display shows the system mode is in. Use two dry cell batteries (AAA. LR03 (alkaline)). Put dry batteries correctly to fit their (+) and (­). (3) Close the cover COOLING, HEATING, AUTOMATIC AND FAN OPERATION (Fig. 3, 4) · AUTOMATIC OPERATION can be selected only by Heat recovery system. · Cooling only system give selection of FAN or COOLING OPERATION only. When to change batteries Under normal use, batteries last about a year. However, change them whenever the indoor unit doesn't respond or responds slowly to commands, or if the display becomes dark. FOR SYSTEMS WITHOUT COOL/ HEAT CHANGEOVER REMOTE CONTROL SWITCH (Fig. 3) Press OPERATION MODE 1 SELECTOR button several times and select the OPERATION MODE of your choice as follows. COOLING OPERATION. . . . . . . . . . . . . . . . . . " HEATING OPERATION . . . . . . . . . . . . . . . . . . . " AUTOMATIC OPERATION . . . . . . . . . . . . . . " FAN OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . " " " " " English 6 On AUTOMATIC OPERATION In this operation mode, COOL/HEAT changeover is automatically conducted at a present indoor temperature. [. . . ] There is nothing wrong with the equipment. Press the INSPECTION/TEST button to select the inspection mode " ". 1 " " appears on display and blinks. "UNIT" lights up. Press PROGRAMMING TIMER BUTTON and change the unit number. 2 Press to change the unit number until the indoor unit beeps and perform the following operation according to the number of beeps. Number of beeps 3 short beeps . . . . . Perform all steps from to 6 . 1 short beep . . . . . . . Perform 3 and 6 steps. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN BRC4C62

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN BRC4C62 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag