User manual DAIKIN DCS601C51

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DAIKIN DCS601C51. We hope that this DAIKIN DCS601C51 user guide will be useful to you.

Lastmanuals help download the user guide DAIKIN DCS601C51.


Mode d'emploi DAIKIN DCS601C51
Download
Manual abstract: user guide DAIKIN DCS601C51

Detailed instructions for use are in the User's Guide.

[. . . ] Operation Manual intelligent Touch Controller Before use Safety Considerations System Overview Features and Functions Part Names and Functions Part Names on the Monitoring Screen and the Functions List Icon 7 9 Operation Operation Quick Reference Air Conditioner Operation Monitoring Operation of Air Conditioner System Setup Menu 13 15 26 32 Precautions Maintenance Model LCD Maintenance When Leaving the Product Turned OFF for a Long Time 83 84 84 85 DCS601C51 ¡Thank you for purchasing intelligent Touch Controller. ¡This operation manual contains notes for safe use of the product. Troubleshooting For Your Information Options Specification After-sales Service For correct use, be sure to read this manual carefully before use. ¡When you have read this manual, be sure to store it in a place where the operator can conveniently refer to at anytime. In case of personnel change, be sure to give the manual to the new operator. 93 94 95 Use smart and save smart For Your Information Maintenance Maintenance Operation Before use Be sure to follow the instructions below 1 3 4 5 Safety Considerations Please read these "SAFETY CONSIDERATIONS" carefully before installing air conditioning equipment and be sure to install it correctly. After completing the installation, make sure that the unit operates properly during the start-up operation. [. . . ] The settings of the simple interlock control are described below. · The simple interlock can store a maximum number of 128 program registrations. For each program, the following settings can be made : · Interlock input point The target groups you want to monitor as the interlock input points (e. g. air-conditioning unit, Di unit*, Dio unit*, HRV) are registered. * : Monitoring is performed for the input states at the operation / stop connection point. In one program, the maximum number of 128 groups can be registered. · Interlock output "Select conditions of interlock input points", "Registration of control targets", and "Settings of control details" are performed. · "Select condition of interlock input points" The interlock control function is initiated when the groups specified as the interlock input points indicate the operation states described below. Select from (1)-(5) to specify the condition. (The control function is actually initiated when the state of the input point has changed. ) (1) No detection : Detection of inputs is not performed. (The control function is not effective. ) (2) Any one or more of the groups ON : When any one or more of the groups registered as the input points turn on, the control function is initiated. (3) All ON : When all of the registered groups as the input points turn on, the control function is initiated. (4) Any one or more of the groups OFF : When any one or more of the groups registered as the input points turn off to stop, the control function is initiated. (5) All OFF : When all of the registered groups as the input points turn off to stop, the control function is initiated. *1 Selecting "Any one or more of the groups ON (or OFF)" while some interlock input points are already ON (or OFF) will not initiate anew the interlock control function even when another interlock input point turns ON (or OFF). (Once the selected condition has become invalid and then, when the selected condition is satisfied again, the function can be initiated. ) *2 When a communication error occurs in any of the interlock input points, the condition will be checked only for the interlock input points in the normal communication state. Operation (Reference) See pages 79 to 80 · "Registration of control targets" A single group or zone, which is to be controlled when the interlock condition is met, is registered. * If the interlock condition has been met during a communication error in the control target, the interlock control function will not be initiated even when the communication error is cleared. · "Settings of control details" Details of the control operations for the target device where the interlock condition is met are defined. The available control operations are described below. Multiple operations can be set at a time. : Start Command and Change Temperature Setting) · Start / Stop commands · Operation mode switching · Change temperature setting · Setting of permission / prohibition of hand-held remote controller operations (Start / Stop, Temperature setting, Operation mode switching) · Ventilation mode switching (*) · Ventilation amount switching (*) * for HRV For one interlock program, two interlock outputs at the maximum can be specified. 50 Operation System Setup Menu Item Description Control operations when a communication error occurs in the interlock input points Example 1) When a communication error occurs in any of the interlock input points, the condition will be checked only for the interlock input points in the normal communication state. 1-00 1-01 1-02 1-03 Operation (Reference) See pages 79 to 80 When "All ON" is selected, the state change shown in the left figure can initiate the interlock control function. Example 2) Even if the interlock input point recovered from the communication error meets the specified condition, the interlock control function cannot be initiated. 1-00 1-01 1-02 1-03 When "Any one or more of the groups ON" is selected, the state change shown in the left figure cannot initiate the interlock control function. Example 3) When a communication error occurs in an interlock input point and, consequently, the specified condition is met, the interlock control function cannot be initiated. 1-00 1-01 1-02 1-03 Even when "All OFF" is selected, the state change shown in the left figure cannot initiate the interlock control function. Control operations when a communication error occurs in the control target equipment Condition of interlock input interlock input point 1-00 1-01 1-02 1-03 Control target equipment 1-10 points : "All ON" is selected. The condition of interlock input points is not met. (1) (2) Although the condition of interlock input points is met, the communication error in the control target will not allow initiating the interlock control function. Even when the control target recovers from the communication error, the interlock control function is not initiated. (3) (4) In this case, once the condition of interlock input points has become invalid and then, when the condition is satisfied again, the interlock control function can be initiated. (5) 51 System Setup Menu Item Description In the following section, utilization of the simple interlock control function is described while giving some examples. Referring to the figure below, the setting examples of the simple interlock control program are provided. [. . . ] While the command is input, neither the central management devices nor remote control can operate air conditioners. When the compulsory stop input command is canceled, the System Compulsory Stop disappears, which allows control with the intelligent Touch Controller. System Compulsory Stop indication? 89 Before Having the Product Serviced Item The air-conditioning unit does not operate. Description and Corrective Action The air-conditioning unit might be stopped by the simple interlock control function. Check the settings of the simple interlock function. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN DCS601C51

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN DCS601C51 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag