User manual DANBY SAC7304D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DANBY SAC7304D. We hope that this DANBY SAC7304D user guide will be useful to you.

Lastmanuals help download the user guide DANBY SAC7304D.


Mode d'emploi DANBY SAC7304D
Download
Manual abstract: user guide DANBY SAC7304D

Detailed instructions for use are in the User's Guide.

[. . . ] Instead, they are requested to directly contact a designated service center or the outlet at which the product was purchased. x Never spill any kind of liquid into the unit. Should this happen, unplug or main switch off the unit and contact an authorized service center. x Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury. [. . . ] You can : Note E-8 Adapt the Turbo, Long function and Fan Speed, Timer settings to your specific requirements. You must operate the Turbo, Long function and Off Timer with the remote control. Cooling Your Room You must select the Cool mode if you wish to adjust the : x Cooling temperature x Fan speed when cooling 1 If necessary, press the Result: (On/Off) button. x The power indicator on the control panel comes on. The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being: x Switched on x Stopped lt will start up normally after three minutes. button on the button. IMPORTANT 2 If the is not displayed on the control panel, press the remote control one or more times until it appears. Result: Note x The indoor unit beeps each time you press the x The air conditioner runs in the Cool mode. You can change modes at any time. 3 To adjust the temperature, press the buttons on the remote control or buttons on the control panel one or more times until the required temperature is displayed. Possible temperatures are between 18OC and 30OC inclusive. Result: x Each time you press the buttons: - The temperature is adjusted by 1OC. x The air conditioner starts cooling, provided that the room temperature is higher than the selected temperature. x If the room temperature reaches the set temperature, the air conditioner stops cooling, but the fan is still operating. 4 Select the fan speed by pressing the button on the remote control or button one or more times until the required setting is displayed : Automatic(rotated : Low High Turbo Result: x Each time you press the button, the indoor unit beeps. ) 5 To control the direction of the air flow, refer to page 16. E-9 Heating Your Room You must select the Heat mode if you wish to adjust the : x Heating temperature x Fan speed when heating 1 If necessary, press the Result: (On/Off) button. x The power indicator on the control panel comes on. x The indoor unit beeps. IMPORTANT The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being: x Switched on x Stopped lt will start up normally after three minutes. 2 If the is not displayed on the control panel, press the remote control one or more times until it appears. x You can't select the Turbo and Long function simultaneously. 4 To control the direction of the air flow, refer to page 16. E-12 Operating to the Long Distance The Long function is used to Cool/Auto(cool) your room as far as possible. Result: x Each time you press the buttons: - The temperature is adjusted by 1OC. x The air conditioner starts removing the excess humidity; x the quantity of air is adjusted automatically. 4 The fan speed is selected automatically( : Automatic). 5 To control the direction of the air flow, refer to page 16. E-14 Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. 1 If necessary, press the Result: (On/Off) button. x The power indicator on the control panel comes on. x The indoor unit beeps. IMPORTANT The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being: x Switched on x Stopped lt will start up normally after three minutes. button on the button. 2 If the is not displayed on the control panel, press the remote control one or more times until it appears. Result: Note x The indoor unit beeps each time you press the x The air conditioner runs in the Fan mode. You can change modes at any time. 3 Select the fan speed by pressing the until the required setting is displayed: Low High Turbo Result: x Each time you press the button one or more times button, the indoor unit beeps. 4 To control the direction of the air flow, refer to page 16. E-15 Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit your room, you can adjust the position of the outer air flow blade on the upper part of the unit, thus increasing the efficiency of the air conditioner. 1 Press the Result: button. Cooling Heating Adjust the blade to face. . . Downwards. RECOMMENDATION 2 To stop the blade moving up and down, press the button again. Adjusting the Air Flow Direction Horizontally There are two sets of air flow blades. Just as the outer air flow blade can be adjusted vertically, the inner blade can be adjusted horizontally. 1 Press the Result: button. x The inner blade moves right and left. 2 To stop the blade moving right and left, press the Note button again. x You can't control the airflow direction horizontally in the Long Function x You can't control the airflow direction when the fan doesn't operate in the Heat mode. E-16 Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. [. . . ] If both the indoor and outdoor temperatures are high and you select the Heat mode, the outdoor unit's fan and compressor may stop at times. This is normal; simply wait until the air conditioner switches on again. If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, you must press the (On/Off) button to restart it. Warm air circulation Frost High indoor and outdoor temperatures Power failure E-19 Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges, within which the air conditioner can be used. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DANBY SAC7304D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DANBY SAC7304D will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag