User manual DATALOGIC MAGELLAN 1400I

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DATALOGIC MAGELLAN 1400I. We hope that this DATALOGIC MAGELLAN 1400I user guide will be useful to you.

Lastmanuals help download the user guide DATALOGIC MAGELLAN 1400I.


Mode d'emploi DATALOGIC MAGELLAN 1400I
Download
Manual abstract: user guide DATALOGIC MAGELLAN 1400I

Detailed instructions for use are in the User's Guide.

[. . . ] Magellan® 1400i Omni-Directional Imaging Scanner Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). [. . . ] It simulates keyboard timing and passes the keyboard status to the PC during power-on. START / END PROGRAMMING BAR CODES Disable Power-on Simulation DEFAULT ³ Enable Power-on Simulation ³ 028901 Product Reference Guide 3-33 Interface Related Features Keyboard Wedge -- cont. Control Characters Specifies how the scanner transmits ASCII control characters to the host. Choices are: · · · Disable Control Characters Enable transmission of control characters to host Send characters between 00H and 1FH according to a special function-key mapping table. (This is used to send keys that are not in the normal ASCII set; a unique set is provided for each available scancode set. Reference Appendix E, Keyboard Function Key Mappings. ) START / END PROGRAMMING BAR CODES Disable Control Characters DEFAULT Enable Transmission of Control Characters Enable Function Key Mapping 3-34 Magellan® 1400i Interface Features Keyboard Wedge -- cont. Wedge Quiet Interval This feature does not apply to the USB Keyboard interface. NOTE Quiet Interval is the amount of time to look for keyboard activity before the scanner breaks the keyboard connection in order to transmit data to the host. START / END PROGRAMMING BAR CODES Selectable from 000 (no interval) to 255 in 10 msec increments. To configure this feature, scan the "START/END" bar code above to place the unit in Programming Mode, then the Set Wedge Quiet Interval bar code followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired length. Exit programming mode by again scanning the "START/END" bar code above. DEFAULT SETTING FOR THIS FEATURE: 010 (100 msec) Set Wedge Quiet Interval Product Reference Guide 3-35 Interface Related Features Keyboard Wedge -- cont. Intercharacter Delay This feature does not apply to the USB Keyboard interface. NOTE START / END PROGRAMMING BAR CODES One-half of the delay specified below is inserted between scancodes within each character. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly. Selectable from 000 to 255 in 10msec increments. To configure this feature, scan the "START/END" bar code above to place the unit in Programming Mode, then the "Set Intercharacter Delay, " followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired length. Exit programming mode by again scanning the "START/END" bar code above/ DEFAULT SETTING FOR THIS FEATURE: 000 (No Delay) Set Intercharacter Delay 3-36 Magellan® 1400i Chapter 4 Data Editing Data Editing Overview It is not recommended to use these features with IBM or Wand Emulation interfaces. CAUTION When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a "message string. " The features in this chapter can be used to build specific user-defined data into a message string. There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. Figure 4-1 shows the available elements you can add to a message string: Figure 4-1. Breakdown of a Message String Label ID Transmission: Enable this option to transmit the Label ID you configure for the scanned symbology. OR. . . Prefix Label ID AIM ID Bar Code Data Label ID Suffix AIM ID: This function is used to identify and display the common label identifier for its symbology. When enabled, this ID code will be transmitted before the scanned bar code data. 00 - 20 Characters (ASCII) Please Keep In Mind. . . · Modifying a message string is not a mandatory requirement. [. . . ] RS-232 Setting 1 Check Character Variable Length 4 16 Disable 1 Disable Disable Enable Variable Length 8 50 Disable 1 Disable Variable Length 1 600 1 Interface-Specific Exceptions Page # 5-58 5-65 5-60 5-60 5-61 5-62 5-63 5-63 5-64 5-65 5-66 5-66 5-67 5-68 5-69 5-70 5-71 5-71 5-69 D-10 Magellan® 1400i Appendix E Keyboard Function Key Mappings Keyboard Model Cross Reference Table E-1 summarizes the keyboard models, their defined protocol, scancode set, and some unique features. The remaining tables in this chapter provide the function key maps associated with each of the scancode sets. Keyboard Model Cross Reference TransScancode mission Set Protocol Func. Use Key Country Map Mode Support PC/XT Scan Set 1 No No Model Type PC/XT Foreign ALT Mode AT; PS/2 25-286; PS/2 30-286; PS/2 50, 50Z; PS/2 60, 70, 80, 90, 95 Foreign ALT Mode PS/2 25 and 30 Foreign ALT Mode PC/XT U. S. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC MAGELLAN 1400I

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC MAGELLAN 1400I will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag