User manual DATALOGIC MAGELLAN 8500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DATALOGIC MAGELLAN 8500. We hope that this DATALOGIC MAGELLAN 8500 user guide will be useful to you.

Lastmanuals help download the user guide DATALOGIC MAGELLAN 8500.


Mode d'emploi DATALOGIC MAGELLAN 8500
Download
Manual abstract: user guide DATALOGIC MAGELLAN 8500

Detailed instructions for use are in the User's Guide.

[. . . ] Magellan® 8500/8500 Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. [. . . ] It specifies the prefix that is added to beginning of label transmission. To specify the Global Prefix Character(s): 1. Scan the bar code, SET GLOBAL PREFIX below. You'll need to cover any unused bar codes to ensure the scanner reads only the bar code you intend to scan. Scan the appropriate characters/digits from the keypad in Appendix C that represent the hex designation for the desired character(s). A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits `4', `1', `4', and `2' must be scanned. The selectable range for this option is any hex value from 00 to FF. Up to 20 hex pairs can be designated. To specify "no Global Prefix, " scan 00. If designating the full 20 hex pairs, the scanner will automatically exit Programming Mode when the appropriate amount of digits have been scanned. If designating less than 20 hex pairs, you can end the programming sequence early by scanning the TERMINATE SEQUENCE bar code. Complete the programming sequence by scanning the SWITCH bar code. Product Reference Guide 6-59 Global Prefix -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. SET GLOBAL PREFIX TERMINATE SEQUENCE 6-60 Magellan® 8500 Scanner Global Suffix This feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and Single Cable). It specifies the suffix that is added to end of a label transmission. Three standard options are available below. Contact your dealer for other alternate settings for this feature. · · · No Global Suffix CR -- Carriage Return CR LF -- Carriage Return, Line Feed To set the Global Suffix: 1. Scan your selection from the bar codes below. Complete the programming sequence by scanning the SWITCH bar code. GLOBAL SUFFIX = NO GLOBAL SUFFIX Product Reference Guide 6-61 Global Suffix -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. GLOBAL SUFFIX = CR GLOBAL SUFFIX = CR LF 6-62 Magellan® 8500 Scanner IBM Features IBM Interface Options IBM interfaces offer specific control over interaction with certain devices. The IBM USB interface provides its own set of options. Refer to the feature, IBM USB Interface Options, in this chapter. NOTE Options for this feature are as follows: · · FULL host interface support -- Accepts scanner and scale configuration host commands. Ignore host interface configuration of scanner and scale -- Ignores all scanner and scale configuration host commands. To set this feature: 1. [. . . ] Example: ']e001044123456789'. Product Reference Guide F-13 RSS Expanded · · Prefix must be ASCII characters ']e0'. Label length excluding prefix characters must be at least 1 character. Maximum length is the maximum label size supported by the scanner. Example: ']e001900123456789083103001750'. · I 2 of 5 · · Check character must be included in label data. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC MAGELLAN 8500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC MAGELLAN 8500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag