User manual DATALOGIC QUICKSCAN 6000 PLUS PROGRAMMING GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DATALOGIC QUICKSCAN 6000 PLUS. We hope that this DATALOGIC QUICKSCAN 6000 PLUS user guide will be useful to you.

Lastmanuals help download the user guide DATALOGIC QUICKSCAN 6000 PLUS.


Mode d'emploi DATALOGIC QUICKSCAN 6000 PLUS
Download
Manual abstract: user guide DATALOGIC QUICKSCAN 6000 PLUSPROGRAMMING GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] QuickScan 6000/6000 Plus ® Handheld Laser Scanner Programming Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). [. . . ] Look at the ASCII chart shown on page 38 and identify the ASCII character and the corresponding Hex Code for the ASCII character you will use as the symbology specific identifier. Scan the label identifier label for the symbology identifier that you are going to change. As an example, assume that you want to change the label identifier for EAN-8 from the default setting FF to the ASCII value 8. Scan the Set Symbology Specific Label Identifier barcode for EAN-8. 2. 3. 5. Identify the hex value that correspond to the ASCII character. In this example '8' equals 38 hex. Simply follow the hex value for '8' (38hex) with the One Character Only label. This tells the scanner that '8' is a single digit label identifier. 6. Scan the barcodes values. For the example in step five, scan 3, 8, One Character Only on the following two pages. NOTE If you make a mistake, or lose your place while setting this option, scan the END label to exit Programming Mode. The scanner will sound an error tone (six rapid beeps) to indicate that programming was incomplete, and the setting will remain as it was before entering Programming Mode. 7. Scan the END label. You have changed the default label identifier for EAN-8 from 'FF' to '8'. Programming Guide 43 Disabling Label I. D. for a Specific Symbology This procedure is the same as setting a single character symbology identifier, except you should scan two zeros and the One Character Only labels before scanning the END label. Symbology Specific Label Identifiers Characters Use the labels on this page to change or modify symbology identifiers. 0 -----------------------------------1 -----------------------------------2 -----------------------------------3 -----------------------------------4 -----------------------------------5 -----------------------------------6 -----------------------------------7 -----------------------------------8 -----------------------------------9 ------------------------------------ 44 QuickScan 6000/6000 Plus A-----------------------------------B-----------------------------------C ----------------------------------D ----------------------------------E-----------------------------------F -----------------------------------ONE CHARACTER ONLY -----------END ---------------------------------------------- Programming Guide 45 Symbologies Symbology selection (bar code type) determines which symbologies the scanner will decode. The chart below shows the symbologies that are supported by each interface. Once you have identified the symbologies you wish to enable, turn to the following pages, enable those symbologies and set the data format options (e. g. check digit, start/stop characters) required by your host system for each symbology type. You must enable the symbology format options settings that are compatible with your host system. The factory settings for each interface were chosen to meet the standard industry requirements and in most cases you will not need to change the symbology format settings. If you are unsure of your system requirements, test the scanner using the factory settings before making any changes. INTERFACE TYPE IBM Port 5B IBM Port 9B IBM Port E NCA OCIA (8 bit) NCA OCIA (9 bit) Datalogic OCIA SNI OCIA Wand Emulation RS-232 Keyboard Wedge KEY { 46 QuickScan 6000 and QuickScan 6000 Plus QuickScan 6000 Plus The symbology can be enabled through configuration item; however, labels will not be decoded or transmitted by the interface. UPC-A & E, EAN-8 & 13 UPC/EAN w/P2 Add-ons UPC/EAN w/P5 Add-ons UPC/EAN w/C128 Add-ons Code 39 Code 39 Pharmacodes Interleaved 2 of 5 Interleaved 2 of 5/IATA Standard 2 of 5 Codabar Code 93 Code 128 MSI/Plessey QuickScan 6000/6000 Plus Symbology Options Overview Enable All Symbologies -- allows the scanner to auto-discriminate between all the symbologies in this list. Use this selection only if you must constantly read a wide variety of symbologies. Turn to the following pages for enabling additional symbology specific options. Disable All Symbologies -- disables all symbologies1. The scanner will only recognize the programming labels contained in this manual while you are in Programming Mode. Enable UPC/EAN -- tells the scanner to recognize UPC-A, UPC-E, EAN8, and EAN-13. If you enable this symbology, additional options for symbology expansion and reading add-ons are available. Allows selection of expansion and add-on options. Enable Code 39 -- selects Code 39 as an active symbology. [. . . ] Scan the label on the following page representing the amount of times you wish a bar code label of that symbology type to be read before transmission to the host. Repeat steps one through three above until read verification has been selected for all symbologies you desire to be verified. 5. SET ---------------------------------------------VERIFY UPC-A ------------------- READ VERIFICATION SYMBOLOGY TYPE 1 VERIFY UPC-E ------------------VERIFY EAN-8 -------------------VERIFY EAN-13 -----------------VERIFY INSTORE LABEL1 -------------------VERIFY CODE 39 ------------------ Instore labels are UPC-A bar codes with a number system character of 2 or 4, and EAN-8 and EAN-13 bar codes with a Flag 1 character of 2. Programming Guide 83 VERIFY INTERLEAVED 2 OF 5 -----READ VERIFICATION SYMBOLOGY TYPE VERIFY STANDARD2 2 OF 5 -------VERIFY CODABAR------------------VERIFY CODE 93 -----------------VERIFY CODE 128 ---------------VERIFY MSI/PLESSEY ------------- VERIFY READS (APPLIES TO ALL SYMBOLOGIES ONE READ ------------------------TWO READS -----------------------THREE READS ---------------------FOUR READS -------------------------------------------------------------------- END 2 The Standard 2 of 5 symbology is available for QuickScan 6000 Plus scanners ONLY. 84 QuickScan 6000/6000 Plus Low Power Mode QuickScan 6000/6000 Plus incorporates two optional low power modes to optimize power usage and extend scanner life. NOTE These features are only available with RS-232, Wand Emulation and Keyboard Wedge host interfaces. WARNING DO NOT use Very Low Power Mode in conjunction with Stand Mode, as this feature is not compatible and may cause unexpected behavior. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC QUICKSCAN 6000 PLUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC QUICKSCAN 6000 PLUS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag