Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DATALOGIC QUICKSCAN QS2500. We hope that this DATALOGIC QUICKSCAN QS2500 user guide will be useful to you.
Lastmanuals help download the user guide DATALOGIC QUICKSCAN QS2500.
Manual abstract: user guide DATALOGIC QUICKSCAN QS2500
Detailed instructions for use are in the User's Guide.
[. . . ] QuickScan® QS2500
Handheld Bar Code Scanner
Product Reference Guide
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). [. . . ] If a double confirm is set, the multifield scan function will be disabled.
Start Program
Option Bar Code
Option
Good-read off
Alphanumeric Entry
00 01* 02 03 04 05 0199 10* 0199 50*
Scanning Mode
Momentary Alternate Timeout off Continue/Scan Mode Test only 099 (sec. )
Standby Duration 099 (10 msec. ) Same Bar Code Delay Time 099 (0 = no double confirm)
Double Confirm
0009 00* Exit
$$
Product Reference Guide
17
Global Minimum/Maximum Code Length: Global minimum and maximum
length can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. Labels with length exceeding these limits will be rejected. Make sure that the minimum-length setting is no greater than the maximum-length setting; otherwise, the labels of the symbology will not be readable. In particular, you can set the same value for both minimum and maximum lengths to force decoding of only fixed-length bar codes. This setting has no effect on certain symbologies of fixed length.
NOTE
Set the minimum/maximum length if you have a special demand for individual bar codes. Include the checksum digits if you want to set global minimum/maximum code length.
Start Program
Option Bar Code
063 Global Minimum Code Length 063 Global Maximum Code Length
Option
Alphanumeric Entry
0063 04*
0063 63* Exit
$$
18
QS2500
Inverted Image Scan: With this option enabled, the QS2500 will scan
black/white bar codes with a white/black background.
CTS Trigger: This operation enables an external device to control scanning by applying an external trigger signal to the CTS input. When active, this signal causes scanning to begin as the QS2500's trigger is depressed. Visible Scan Field Indicator: This function allows a visible indicator to be
emitted when the trigger is pulled.
Start Program
Option Bar Code
Option
Disable
Alphanumeric Entry
00* 01 00* 01 00* 01 02 03 04 05 06 07 Exit
Inverted Image Scan
Enable Disable
CTS Trigger
Enable Disable
Visible Scan Field Indicator
30 second 60 second 90 second 120 second 150 second 180 second Continuous
$$
Product Reference Guide
19
Beep/Tone/LED Settings
Power-On Alert: After power-on, the QS2500 will generate an alert signal to
indicate a successful self-test.
LED Control: After each successful bar code reading, the LED above the QS2500 will light up. Beep Control: After each successful bar code reading, the QS2500 will
beep.
Beep Loudness/Beep-Tone Frequency/Beep-Tone Duration: You can adjust the
loudness, tone, and duration of the good-read beep.
20
QS2500
Start Program
Option Bar Code
Option
Disable
Alphanumeric Entry
00 01* 00 01* 00 01* 0007 03* 0099 26* 0099 10* 00 01* 00 01 00 01 Exit
Power-On Alert
Enable Disable
LED Indication
Enable Disable
Beeper Indication
Enable 007
Beep Loudness 099 (100Hz) Beep-Tone Frequency 099 (10 msec. ) Beep-Tone Duration Disable Beep/Lamp Option 1:
Beep & LED after decode
Beep/Lamp Option 2:
Enable Disable
Beep & LED after data transmission
Beep/Lamp Option 3:
Enable
Disable
Beep & LED after data transmission & CTS active
Enable
Product Reference Guide
21
Label Editing (includes Prefix/Suffix)
Prefix Characters: Up to 22 ASCII characters may be sent before data. Prefix Data Suffix
Suffix Characters: Up to 22 ASCII characters may be sent after data. Preamble/Postamble Characters: These characters are affixed to the data automatically when each bar code is decoded. Example: Add a prefix/suffix or preamble/postamble for all symbologies. In
this example, you can send a `$' symbol as a prefix for all symbologies by completing the following steps: 1. Scan the Start Program and Prefix Characters Setting bar codes below. Use the ASCII code table (see Appendix C - page 66) to find the ASCII value for $(24hex). Scan the bar codes for 2 and 4 on the inside back cover of this manual. Scan the Store Settings bar code on the inside back cover. Scan the Exit bar code.
Insert G1/G2/G3/G4 Character Setting: The QS2500 offer four positions and
four characters to insert into the symbol data.
Example:
Bar code: "1 2 3 4 5 6". Output: "1 2 A B 3 4 C D 5 6".
1. Scan Start Program and Insert G1 Characters Setting bar code below. Use the ASCII code table (see Appendix C on page 66) to find the ASCII value for A (41) and B (42). [. . . ] Checksum Transmission: When this option is enabled, the QS2500 will
transmit the checksum.
Maximum/Minimum Code Length: Same as Code 39. Insertion Group Selection: Same as UPC-A. See page 27.
Product Reference Guide
51
Start Program
Option Bar Code
Option
Disable
Alphanumeric Entry
00* 01 00 01* 00* 01 00* 0164 00* 0164 0015 00* 0015 00* 00ffhex<@>*
Read
Enable Disable
Checksum Verification
Enable Disable
Checksum Transmission
Enable Use Global Max.
Max. Code Length
164 Use Global Min.
Min. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC QUICKSCAN QS2500
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC QUICKSCAN QS2500 will begin.