User manual DAXTEN IP-810 BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DAXTEN IP-810. We hope that this DAXTEN IP-810 user guide will be useful to you.

Lastmanuals help download the user guide DAXTEN IP-810.


Mode d'emploi DAXTEN IP-810
Download
Manual abstract: user guide DAXTEN IP-810BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] iPAL Web Controlled Power Switches Overview The iP-4xx and iP-8xx series are network attached, IP addressed, Web Controlled, multi outlet, remote A/C power switches. The following models are covered in this manual. iP-820 iP-420 iP-815 iP-415 iP-810 iP-410 8 switched outlets, for use on 115 VAC, 20 Amp Service ­ NEMA N5-20 4 switched outlets, for use on 115 VAC, 20 Amp Service ­ NEMA N5-20 8 switched outlets, for use on 115 VAC, 15 Amp Service ­ NEMA N5-15 4 switched outlets, for use on 115 VAC, 15 Amp Service ­ NEMA N5-15 8 switched outlets, for use on 115/230 VAC, 12 /10 Amp International ­ IEC 320 4 switched outlets, for use on 115/230 VAC, 12 /10 Amp International ­ IEC 320 "M" suffix designations in the model name indicate models equipped with an internal modem. Any Networked PC Running Web Browser or Telnet Dial-up In-Band and Out-of-Band Control TCP/IP over 10base-T Ethernet Power Control 4 or 8 Devices Table of Contents Important Safety Information Hardware Installation iPAL Configuration IP Address Setting up Dial-Up Networking Configuration Parameters Telnet Operation Web Browser Operation Specifications Tech Support & Warranty 13 14 15 16 2 3 7 REF: PWR\IP8xx_UL_V020318D. DOC Technical Support Hotline: (201) 967-8788 11 Park Place / Paramus, New Jersey 07652 TEL: 201-967-9300 FAX: 201-967-9090 Website: www. dataprobe. com Email: tech@dataprobe. com iPAL Page 2 Important Safety Instructions When using this product, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. [. . . ] A standard IEC to NEMA 5-15 cord set is supplied with the unit for use on 15 Amp 115VAC service. The total maximum current load for all outlets cannot exceed 12 Amps at 115VAC or 10 Amps when used at 230VAC iPAL Page 6 iPAL Configuration Configuration of the iPAL involves the following steps: 1) Setting iPAL's IP Address 2) Configuring Dial-up Networking (Optional) 3) Setting Configuration parameters using Telnet 1) Setting I/P Address iPAL comes with factory installed IP address 192. 168. 1. 254. In most cases this will need to be changed. Consult your Network Administrator to determine the appropriate IP address. The iPAL uses ARP to configure the IP address. To set the IP address, the hardware (MAC) address must be known. This address is located on a label on the bottom of the unit, and on the iPAL printed circuit board. The syntax for the MAC address is: nn-nn-nn-nn-nn-nn Setting the IP address using ARP To set the IP address using ARP, connect the 10Base-T connection to your local ethernet network and apply power to the unit. The computer used to set the IP address must be on the same local network as the iPAL. ARP does not work across routed networks. Windows 3. 11, 95 and NT 1. Type the following command: arp -s <IP Address> <MAC Address> Where <IP Address> is the desired IP address for the iPAL and the <MAC address> is the MAC Address of the iPAL. The MAC Address of the iPAL is located on the iPAL's serial number label. Ping the device to confirm that the address has been programmed properly by typing the following: ping <IP Address> If the ping command returns "host not responding" 4 times then the address has not been programmed properly, or the IP Address is incorrect. If the problem persists contact the Dataprobe Tech Support Hot Line. Delete the entry from the ARP cache by typing: arp -d <IP Address> Note: Due to a bug in the Windows 95 version of ARP you must first have and empty ARP table (seen with arp -a). To empty an arp table type arp -d <ip address> for each entry in the arp table as seen with arp -a. Ping an existing device on your network before setting the IP Address of the IPAL. This device must be a network device other then the one currently being used. Unix, Linux Consult your systems administrator for information on setting an IP Address using ARP. The unit should be pinged after the IP Address has been set to confirm proper operation. iPAL Page 7 2) Configuring Dial-up Networking Use of the Internal modem (if provided) or use of an external modem require the setup of PPP connection using Dial-up Networking. The following describes the procedure for setup in Windows 98. If you computer supports another operating system, consult your network administrator for proper setup details. A) Using Make a New Connection in Dial-up Networking, setup a Dial-Up Networking connection. Set the desired modem and telephone number you wish to use. [. . . ] Enter the Password (no User Name is necessary) as set in the Telnet configuration. Remember; the password is case sensitive. When the password is properly entered, click OK. This brings up the Control and Status screen: This screen provides all the control and status information required. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAXTEN IP-810

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DAXTEN IP-810 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag