Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DE DIETRICH DCM5102R. We hope that this DE DIETRICH DCM5102R user guide will be useful to you.
Lastmanuals help download the user guide DE DIETRICH DCM5102R.
Detailed instructions for use are in the User's Guide.
[. . . ] Trouble shooting minor faults and anomalies Gas cooking guide Induction ring cooking guide After Sales Service
Throughout the manual, Indicates safety instructions, Indicates advice and tips
29
Editorial
Dear Customer, You have just bought a DE DIETRICH hob. Our research teams have designed a new generation of appliances, which with their quality, a designer look and a technological advances are outstanding products revealing a unique know-how. With its contemporary, refined lines your DE DIETRICH hob will blend harmoniously with your kitchen, combining perfect technological mastery with excellent cooking performances and a luxury finish. In the range of DE DIETRICH products, you will also find a vast choice of ovens, hoods, dishwashers and built-in refrigerators that you can match up with your DE DIETRICH hob. [. . . ] Refer to the paragraph "Connecting to the gas supply". CHANGE THE INJECTORS as follows: · Remove all the pan supports and burner caps and heads. · Using the wrench provided, unscrew the injectors at the bottom of each dish and remove them (fig 2).
40
GAS SUPPLY
CHANGING SWITCH
Pan support Cap Head dish Fig. Connect to the electricity supply.
BUTANE
Network gas (natural gas)
Fig. 1
GAS SUPPLY
CHANGING SWITCH
Pan support Cap Head Crucible Fig. 4
Wrench
YOUR HOB IS NOW READY TO RUN ON NETWORK GAS (NATURAL GAS)
42
Easily install your hob EN
Changing the gas supply (continued)
Gas characteristics
FR-GB ES-PT FR-GB ES-PT FR-GB FR ES-PT
Appliance intended to be installed for use with: FR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat : II2E+3+ GB - ES - PT . . . . . . . . . . . . . . . . . . . . . Cat : II2H3+ Hourly rate below At 15°C under 1013 bar High speed burner Mark marked on the injector Nominal heat release rate (kW) Reduced heat release rate (with safety mech. ) (kW) Hourly rate (g/h) Hourly rate (l/h) Semi-fast burner Mark marked on the injector Nominal heat release rate (kW) Reduced heat release rate (with safety mech. ) (kW) Hourly rate (g/h) Hourly rate (l/h) Hob total Total heat release rate (kW) Maximum rate (g/h) (l/h)
Butane G30 28-30 mbar
Propane G31 37 mbar
Natural gas G20 20 mbar
Natural gas G25 25 mbar
88 3. 10 0. 830 225
88 3. 10 221
137 3. 10 0. 870 295
137 3. 10 343 94 1. 5 166 4. 60 509
62 1. 45 0. 620 105
62 1. 45 104
94 1. 5 0. 615 143
4. 55 330
4. 55 325
4. 60 438
MARKING OF THE INJECTORS
The table opposite shows where the injectors are positioned on your appliance according to the type of gas used. Each number is marked on the injector.
MARKING OF THE INJECTORS Natural gas Butane/propane gas
94
137
62
88
Operating voltage - Standby consumption - Max operating consumption Total electric power absorbed Dimensions of the hob: - Width - Depth Weight Dimensions of housing: - Width - Height - Depth
220-240 V~ - 50 Hz 2, 5 Wh 20 Wh 3100 W (1) 650 mm 520 mm 11, 4 kg 549 mm 59 mm 470 mm 43
(1) The heating powers are given only by way of indication. They depend on the pan's type and shape. Subject to modifications.
Easily install your hob
Connecting the electricity supply
Gas hob · This hob comes with a power cable (H05V2V2F, cross-section 1. 5 mm2) with 3 conductors (including 1 for the earth: yellow/green). These conductors must be connected to the network by means of a CEI 60083 standardised phase + earth + neutral plug or an omnipolar cutout device conform to the installation guidelines currently in force. CABLE CROSS-SECTION TO BE USED
220-240 V~ - 50 Hz
H05V2V2F - T90
3 conductors including 1 for the earth 1, 5
Cross-section of conductors in mm2 Fuse
16 A
The plug must be accessible after installation. The burner will continue to function without the timer.
For the last minute, the countdown will be displayed in seconds. -When the cooking time has elapsed, the burner will automatically go out (the supply of gas to the burner will be cut off). 46
Use your hob in complete simplicity EN
Which pans are compatible with gas rings?
· Recommended pan diameters:
Large burner HIGH SPEED 18 to 28 cm Medium-sized burner SEMI-FAST 16 to 22 cm
Adjust the ring of flames so that they do not go over the edge of the pan.
RIGHT
WRONG
Do not use pans with concave or convex bases. Do not leave a gas ring burning beneath an empty pan. Do not use pans that partially cover the control panel. Do not use diffusers, toasters, steel meat broilers and stewpots with legs resting on or touching the glass top.
CONVEX
CONCAVE
Keep the natural ventilation holes open, or install a mechanical ventilation device (mechanical ventilation hood). Intensive and prolonged use of the appliance may require additional ventilation, for example, by opening a window or through more effective ventilation, for example by increasing the mechanical ventilation power if such exists (a minimum air flow of 2 m3/hr per kW of gas power if necessary). Example for this hob: Total power: 1. 5 + 3. 1 = 4. 5 kW. A minimum rate of 4. 5 kW x 2 = 9 m3/hr Using a gas cooking appliance causes the production of heat and humidity in the room where it is installed. Make sure that your kitchen is well ventilated. As a safety measure, don't forget to turn off the network gas general control or the butane/propane gas cylinder tap after use. [. . . ] Call your After Sales Service, specifying the error code displayed. Call your After Sales Service.
displays E7: one of the indicators lights up to indicate the faulty burner displays E8 and several indicators light up to indicate the faulty burners.
There is a flame or a hot object on the safety element (thermocouple).
The hob has 2 faults.
Call your After Sales Service, specifying the indicators lit.
The displaying of an error code automatically inhibits use of the timer
. 51
Trouble shooting minor faults and anomalies
WHAT IS HAPPENING ?
Igniting of the burners: No sparks are produced when the keys are pressed
WHAT SHOULD BE DONE?
Check the electrical connecting of the hob Check that the electrodes are clean Check that the burners are clean and correctly assembled
When a burner is ignited, sparks are produced at all the burners
This is normal. The ignition function is centralised and controls all the burners at the same time.
Check that the gas inlet is not trapped Check that the inlet length is less than 2 metres. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DE DIETRICH DCM5102R
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DE DIETRICH DCM5102R will begin.