User manual DELONGHI BLUE FLAME GAS HEATER SBF

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI BLUE FLAME GAS HEATER SBF. We hope that this DELONGHI BLUE FLAME GAS HEATER SBF user guide will be useful to you.

Lastmanuals help download the user guide DELONGHI BLUE FLAME GAS HEATER SBF.


Mode d'emploi DELONGHI BLUE FLAME GAS HEATER SBF
Download
Manual abstract: user guide DELONGHI BLUE FLAME GAS HEATER SBF

Detailed instructions for use are in the User's Guide.

[. . . ] If the cylinder valve appears to be leaking when turned off, refit the Black Branch Cap or Orange valve Cap. - This appliance MUST NOT be used in a basement, high rise flats, bathrooms or bedrooms and in rooms having volume less than 15 m3 (30m3 in living rooms) for three burner models; 18m3 (36m3 in living rooms) for two burner models. - Be sure installation is complying to local standard. - Do not install the appliance in a room which might contain gas, oil or sulphur, or near sources of heat. [. . . ] Note: Quick-on is so designed as to prevent it from being fitted to the valve, unless the regulator handle is in the closed position; therefore, never attempt to mount or dismount it, if the handle is not in this position. OPEN Handle vertically flame On Handle horizontally flame Off CLOSED fig. 3 Operation Once the Quick-on is correctly mounted on the valve, gas supply is possible by turning the regulator handle upwards (counterclockwise). To shut off the gas supply, reverse above procedure; an arrow engraved on the handle indicates the closing direction (fig. 3). Symbols engraved on the bonnet show how to operate the regulator handle. CAUTION: if you are unable, to open the regulator handle, this means that your Quikon is not correctly connected to the valve. Do not force the handle to open, instead start again the operations described above in 3. GAS OFF Replacement of a cylinder Make sure that: - all taps on the consuming appliance are in the closed position. - the Quick-on regulator handle is in the closed position. Then, dismount the Quick-on by pressing horizontally on the handle and pulling upwards at the same time (fig. 5). Do not attempt to carry out this operation with the regulator handle in the open position. fig. 4 2 1 GAS OFF fig. 5 3 GENERAL SAFETY INSTRUCTIONS Type Category See Rating label Max. output Kw 4. 2 g/h 305 Med. output Kw 2. 85 g/h 207 Low output Kw 1. 50 g/h 109 Gas Presure Gas combustion air quantity 8. 4 m3/h 28-30 mbar this appliance is designed to operate with butane, at nominal pressure: 28÷30 mbar CYLINDER VALVE If heater does not competely extinguish, including pilot, when gas is turned off at the regulator, do not remove regulator. Return valve to open position and leave heater alight, which is perfectly safe, until attended to by the gas supplier. Regulators, Hoses and clips Check that tubing is completely over the nozzles at each end of the tubing and that is held firmly in place by tube clips. Examine flexible tubing regularly and get your Dealer to fit new tubing 400 mm long if perished, worn or damaged. ATTACKS NATURAL RUBBER-USE ONLY TUBING TO B. S. Avoid bending or constricting the rubber tube when the pressure regulator is connected to the gas cylinder. 3016 SET AT 28 MBAR (11. 2 IN W. G. ) for butane must de connected to the appliance with the above tubing, using suitable tube clips. VENTILATION USE ONLY IN A WELL VENTILATED ROOM Adequate ventilation must be provided in rooms in which the heater is use. This ensures removal of the products combustion and allows the entry of replacement air. Adequate ventilation should considerably reduce the possibility of condensation accurring. The following table shows the smallest size of room suitable for each heat setting and the ventilation which must be provided. Heating Setting Room Size 15 m3 Room Vent MIN MAX 42 m3 105 cm2 MED 28, 5 m3 MAINTENANCE Ensure that the heater is kept free of dust. When the heater is not in use it should be covered and stored in a dust-free place. Stains on the exterior should be removed with soapy solution when the heater is cold. DO NOT use abrasive cleaners which will damage the paint finishes. [. . . ] FROM POSITION, fully depress the control knob, and turn to position (small flame). If pilot does not ignite return to starting position and repeat). Continue to fully depress the knob for a further 10 seconds to allow the thermocouple probe to heat up, then turn the knob to the required heat setting. CONTROL OF THE HEAT OUTPUT: For low output - leave control knob in position (small flame) For full output - slightly depress knob and rotate to position (big flame) For medium output - slightly depress knob and rotate to position (medium flame)(only on some models) TURNING-OFF THE HEATER The heater will only be totally "OFF" when the supply of gas from the cylinder has been turned "OFF" at the regulator valve. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI BLUE FLAME GAS HEATER SBF

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI BLUE FLAME GAS HEATER SBF will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag