User manual DELONGHI PAC A110L QUICK GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI PAC A110L. We hope that this DELONGHI PAC A110L user guide will be useful to you.

Lastmanuals help download the user guide DELONGHI PAC A110L.


Mode d'emploi DELONGHI PAC A110L
Download
Manual abstract: user guide DELONGHI PAC A110LQUICK GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] - The Pinguino should not be installed where the atmosphere could contain combustible gases. - Avoid using Pinguino in oily or sulphurous atmospheres or near sources of heat. - Wait at least 3 minutes before restarting, after the air conditioner has been switched off or the thermostat setting changed. - Before moving the air conditioner, empty water from collectiong tray (see instructions for drainage at page 13). [. . . ] 1 INSIDE 3"1/2 OUTSIDE fig. 3 INSIDE OUTSIDE A2 through the wooden base-section of a door or window 1" 3"1/2 fig. 4 A3 through the wall In case of fixed installation, air discharged from rear hose has been extracted from the room where the appliance is installed. Check that the room (especially if small) is not "air-tight"; a drop in pressure would cause irregular functioning, which could consequently activate reset switch. Air entering through door and window cracks is normally sufficient. If deemed, necessary leave a door ajar (approx. 1 cm is enough). 7 3"1/2 GB 19-05-2003 16:32 Pagina 8 Setting up TEMPORARY INSTALLATION Note: In both cases (permanent and temporary installations) make sure that the Pinguino is positioned on level ground. If necessary use the two caster stops for the front casters This installation makes it easy to use Pinguino in any room, provided there is a window or a door: it allows you to use the Pinguino immediately. window bracket fig. 5 Suction discs may be used to keep window or door closed. If you have a sash door, use the additional set provided in order to extend the accessory to the desired length; joining the two parts (fig. 8), adjust the total lenghth according to your needs then, fix the bracket with the relevant nuts, close the door and connect the hose (fig. 6 Pinguino is equipped with an adjustable window bracket. The unit will now switch on and off each day at the selected times. Note: To override the programmed operating times, simply press the ON/OFF key. NON-PROGRAMMED MODE 1) B TIMER button must be pressed 2) Select the desired function as shown in the chart on the following page. Note: For technical reasons, the temperature is not expressed in degrees but by a line increasing in thickness. We therefore recommend that when starting up the appliance, the thermostat be turned to maximum (thick green line = maximum cold). When the desired temperature has been reached, turn the thermostat slowly away from the maximum cooling position until the appliance switches off. The air-conditioner is now programmed to maintain the exact temperature at all times. After switching the appliance off, wait at least 3 min. before switching on again. 10 GB 19-05-2003 16:32 Pagina 11 How to start up the conditioner Plug the appliance into the mains. Select the "programmed" or "non programmed" mode (see previous page) Select the fan speed required pressing "Fan speed" key C. AIR CONDITIONING Key A ON/OFF (conditioning) must be released Turn the thermostat to Max. ON/OFF signal lamp (conditioning) will come on. The appliance comes on. 14. To switch off the appliance, press key A (ON/OFF main switch). 11 GB 19-05-2003 16:32 Pagina 12 Cleaning and maintenance PRECAUTIONS fig. 15 During cleaning and normal maintenance operations remember to disconnect plug. Under no circumstances should appliance be washed with runing water. [. . . ] 4) Clean filter and dry well before replacing. fig. 23 13 GB 19-05-2003 16:32 Pagina 14 Troubleshooting SYMPTOMS The Pinguino does not function: CAUSE power failure plug is disconnected ON/OFF switch is off Timer key is in STOP position SOLUTION - insert plug switch on release the TIMER key The Pinguino does not function - function fault warning light is on (pag. 10 "Alarm" light) After correcting problem, press reset button (see pag. 5) The Pinguino produces cold air but room does not maintain comfortable temperature: - exhaust hose blocked exhaust hose twisted or bent ventilation holes on the rear of the machine or front louvers blocked window open air exhaust hose has become disconnected thermostat set too low air filter blocked - Check for obstruction of air outlet vent eliminate irregularities remove obstacles to allow proper airflow - - close window re-insert exhaust hose set thermostat to higher number clean filter SERVICING In case of malfunction turn off and disconnect the Pinguino from power outlet and contact our Service Centre for qualified assistance, toll-free number 1-800-322-3848. 14 GB 19-05-2003 16:32 Pagina 15 LIMITED WARRANTY We warrant each DE'LONGHI AIR-CONDITIONER to be free from defects in material and workmanship. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PAC A110L

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PAC A110L will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag