If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI PAC A130HPE. We hope that this DELONGHI PAC A130HPE user guide will be useful to you.

Lastmanuals help download the user guide DELONGHI PAC A130HPE.


Mode d'emploi DELONGHI PAC A130HPE
Download
Manual abstract: user guide DELONGHI PAC A130HPEINDEX

Detailed instructions for use are in the User's Guide.

[. . . ] - Clean air filter every week (see instructions at page 12). - Unplug from outlet when not in use and before cleaning. - Important: If you need to use an extension cord, please be sure to use a heavy duty extension cord (minimum 14 gauge). SAVE THESE INSTRUCTIONS 3 GB 14-05-2001 8:18 Pagina 4 SPECIFICATIONS Power supply voltage Frequency Cooling capacity: Current consumption Air flow capacity Room thermostat V Hz see rating label* 60 see rating label* see rating label* 188. 35 cfm adjustable Dimensions : width height depth in. (mm) in. (mm) in. (mm) 18. 03 (458) 33. 46 (850) 15. 74 (400) Net weight Refrigerant system Compressor protection Freon charge lb. (kg) 97 (44) R 22 Overload relay see rating label* *Data according to pending standard testing procedures subject to review by the U. S. [. . . ] If the window is fitted with shutters or blinds, these should be partially closed in order to reduce exposure to direct sunlight and to prevent warm air from entering the room. N. B. : Check that the air-conditioner is perfectly level. If necessary, fit the special stops to the two front castors. OFF OF ON ON F 11 10 9 6 USING THE UNIT AS A DEHUMIDIFIER · Position the unit anywhere in the room to be dehumidified without fitting the exhaust hose, so that the air is vented directly into the room. Condensed water is drained alway as follows: Remove the condensation tube from the rear compartment and connect a floor-level drainage duct. The condensation tube can be fitted with an extension tube (maximum lenght 2 m. / 6. 5 ft. ) . The extension tube must be of the same diameter and positioned at floor level. The condensation can also be drained into a basin (maximum height 11cm. /4. 3 ins). In this case, care should be taken to prevent overflowing. OF F I ON When the dehumidifying a room whose temperature is lower than 18°C (64°F), the unit must be operated with the timer inserted (see pag 9) and set as follows: 1 hour ON 15 min. OFF When the unit is used as an air-conditioner, in order to have the right confort the appliance besides cooling, it also redueces the the humidity in the room. When the unit is used as a dehumidifier, in order to enforce the dehumidification process, the appliance, besides dehumidifying, it also heats the room. 7 GB 14-05-2001 8:18 Pagina 8 ELECTRICAL CONNECTIONS Before plugging the unit into the mains, check the following: · the mains voltage must be the same as the voltage shown on the rating plate · the power socket and the mains circuit must be suitable for the power requirements of the unit · the socket must be suitable for the plug; if not, have the socket replaced. · the power socket must be properly earthed. Th e m a n u f ac tu re d d ec line s all responsability for any damage or injury arising from non-observance of this safety requirement. · · Ensure that the air intake and discharge vents are not obstructed. Make sure that there are no sources of heat in the room. FINAL CHECK In order to ensure that your air-conditioner operates with the maximum efficiency, make sure that: · all doors and windows in the room to be airconditioned are closed (except for temporary installation, in which case a window must be left partially open). It is advisable to begin by turning the thermostat to the maximum setting (thick green line = maximum cooling). When the room temperature is comfortable, turn the thermostat slowly away from the maximum cooling position until the air-conditioner switches off. The air-conditioner is now programmed to maintain the exact temperature at all times. This appliance is fitted with a special safety circuit. When the compressor switches off, this circuit prevents it from switching on again for at least 3 minutes. 10 GB 14-05-2001 8:18 Pagina 11 MAINTENANCE PRECAUTIONS OF F During cleaning and normal maintenance operations remember to disconnect plug. Under no circumstances should appliance be washed with running water. Damage could be caused to the electrical circuit. CLEANING OF EXTERNAL HOUSING Never use petrol, gas, alcohol or solvents for cleaning. Never spray insecticides or similar products on the appliance, as these may seriously damage the paintwork and plastic. O FF OF F QQ , , QQ , , I ON I ON Clean with a damp cloth and dry thoroughly with a clean dry cloth. CONTROLS AT THE BEGINNING OF THE SEASON OF F Carefully follow installation procedure. I ON Check for any defects in power cord and plug. I O N 11 GB 14-05-2001 8:18 Pagina 12 AIR FILTER CLEANING Maintenance of air filter A clogged air filter reduces the quantity of circulating air and the efficiency of the appliance. It is therefore recommended to clean the filter at weekly intervals. Removal and replacement of air filter Gently pull filter upwards (as shown in figure). filter O FF Remove dust with a vacuum cleaner If the filter is very dirty, wash it in lukewarm water and rinse thoroughly. Cleaning procedure To remove dust deposited on filter, use a vacuum cleaner. If it is very dirty, soak in lukewarm water and rinse thoroughly. The temperature of the water must be kept below 40°C (104F). [. . . ] 3) Clean the filter and dry it carefully before replacing. 4) Cover the appliance with a plastic bag to protect it from dust. 12 GB 14-05-2001 8:18 Pagina 13 TROUBLESHOOTING Most malfunctions are caused by a very minor and easily solved problem. Before contacting your nearest authorized Service Center for assistance, consult the troubleshooting chart below. SYMPTOMS The Pinguino does not function: CAUSE power failure the appliance is not plugged in the notches on TIMER dial have not been set switch is off the alarm warning light is on: the safety float has been enabled because the collecting tray inside the unit is too full thermostat has been activated exhaust hose to outside blocked fan blocked SOLUTION wait connect plug either push notches out or disable timer turn main switch on drain water using the drainage tube supplied, see page 5. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PAC A130HPE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PAC A130HPE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag