User manual DEVILLE C07729 INSTALLATION 07-10

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DEVILLE C07729. We hope that this DEVILLE C07729 user guide will be useful to you.

Lastmanuals help download the user guide DEVILLE C07729.


Mode d'emploi DEVILLE C07729
Download
Manual abstract: user guide DEVILLE C07729INSTALLATION 07-10

Detailed instructions for use are in the User's Guide.

[. . . ] The flue's suitability for its intented use . If the flue is not compatible with the stove, install the required tubing using an approved and certificated method (in France, a method that has an "Avis Technique" certificate), or else put in a new flue. 3 General recommendations A good flue should be built using materials that do not conduct much heat so that it stays hot. The flue should be completely smoketight, smooth and stable. [. . . ] The following materials are approved : black plate (min. The connector fitting should be visible over its entire length and capable of being swep mechanically. Expansion should not adversely affect the conduit intake or discharge junctions or its own mechanical stability or that of the main smoke flue. Its design, and more especially its connection to the smoke flue, should be such as to prevent the accumulation of soot, notably during sweeping. Connections to both the stove and the flue should strictly comply with DTU 24. 2 and the conduit manufacturer's specifications and should include all the fittings recommended (end fittings, connecting pieces etc. 4 - DRAUGHT REQUIREMENTS Draught is measured on the connector duct about 50 cm after the stove outlet. The draught required for efficient working with the door closed is as follow : . A damper ensures an efficient operation, even where draught requirements are considerable (high flue and casing). The damper does not habe any effect on the stove when the door is open. This additional air is compulsory when the dwelling is equipped with a mechanical ventilation system. The air intake should be positioned either directly to the outside or in an area having ventilation to the outside. The intake should be equipped with a protective grill. The air outlet should be as near as possible to the stove. The user should be able to close it off when it comes out directly into the room. While the appliance is being used, make sure that it is free of any obstructions. The section of the air inlet must be at least equal to one quarter of the section of the chimney flue with a minimum of 50 cm² for a power rating less than or equal to 8 kW, and 70 cm² for a power rating between 8 KW and 16 KW. It may be necessary to stop the mechanical ventilation fan so as to prevent smoke coming back into the room when the door is opened. 6 ­ WALLS IN THE VICINITY OF THE APPLIANCE The stove should be located at least 300 mm from the rear and side walls of the room and from any combustible materials. In order to protect the floor from heat radiation and possible falling combustible, install the unit on reflective metal shielding (or on a tiled floor) which covers the entire surface underneath and in front of the unit. The appliance must be set up on a floor with a sufficient bearing capacity. If the existing construction does not comply with this prior requirement, appropriate measures must be taken to allow the floor to bear the appliance, such as setting up a load distribution plate. [. . . ] WARRANTY PERIOD The period of the agreed warranty ensured by Deville is for 2 years (5 years for the fireplace heating body) from the date when the appliance was purchased by the user, subject to the fact the claims -forecast by the above conditionswere done within the time allowed. The repairing, the replacement or the alteration of parts under the warranty period can neither have the effect of continuing the period of the latter, not get to any compensation for any fees, for late delivery, accidents or any such damages. EXCLUSION The warranty is unavailable for the following cases, without this list being exhaustive : Fitting out, fitting out and assembling of appliances not due to Deville. Consequently Deville can't be considered as responsible for damages or supplies, or accidents to persons due to local laws and regulations (for example the fact that there is no linking to the earth ground connection or a wrong drought of a fitting out). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DEVILLE C07729

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DEVILLE C07729 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag