User manual DEVILLE C07910-A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DEVILLE C07910-A. We hope that this DEVILLE C07910-A user guide will be useful to you.

Lastmanuals help download the user guide DEVILLE C07910-A.


Mode d'emploi DEVILLE C07910-A
Download
Manual abstract: user guide DEVILLE C07910-A

Detailed instructions for use are in the User's Guide.

[. . . ] You are advised to read carefully and in full the information provided in order to get the best performance - and the most satisfaction - out of your DEVILLE stove. Failure to comply with the assembly, installation and operating instructions places all responsibility upon the person(s) concerned. All local, national, and European regulations must be respected when using this appliance. This insert hearth is a continuous heating appliance with an on-grid combustion, using wood, with a semi-closed combustion chamber. [. . . ] - The pipe's diameter must not be inferior to the blast pipe's diameter of the equipment. If it is the case, the reduction must be of an immediately inferior diameter of the blast pipe and it must be located the farthest possible from the connect to the equipment. - The joining must vertically be done on a pipe leading under the ceiling. - The jointing of the joining pipe to the blast pipe of the equipment as well as to smoke pipe will be tight. As far as accommodation equipped with a CMV (Controlled Mechanical Ventilation) to the blast pipe's one and it must be located as far as possible from the joining to the equipment. The wiring must be realised in compliance with the rules in effect. Switch off power supply before any operation. It is strictly forbidden to have the wire cables go inside the chimney and the hood without them being first insulated from the fire. Radiators : For the appliance to be in proper working order, we recommend the fitting of a heat exchanger with the following power ratings : . 9 kW maximum In any case, half of the radiators should not be fitted with a thermostat. Piping: Installed in accordance with accepted trade, in compliance with the DTU 65-05 and DTU 65-10 standards only to cite both of them. We advice you not to reduce the start and return sections of the fireplace. Pressure of use and feed in water : Pressure of use: 1, 5 bar Maximal pressure: 2 bars The installation must be drained. 7) : The fireplace may be drained after its installation. To do this, you just have to dismantle the front panel unscrewing the 4 screws that link it up to the tub. The draining is then operated by completely unscrewing the cap located at the bottom of the left tub. Carefully check the condition of the appliance, and more especially smoke-tightness : seals, fixings, and door and frame. Check the condition of the smoke flue and the connecting pipe ; all fittings should be in good mechanical condition and be smoke-tight. Clean the extractor fan inside the hood to get rid of any dust and if necessary clear the hot air convection system. in the event of a fault , have the stove or the installation repaired by a qualified tradesman. When cleaning the machine, it is necessary to : Take apart the deflector as pictured, to clean the device. 11b) Close the nozzle key Insert the 1st pipe from the back Set up the 2nd pipe from the front Place the 3rd pipe from the front To set up the metal sheet, present the sheet, lean the sheet up, lift the sheet back up and let it slide down lying on the heating pipes To undo the deflector, reverse the setting up operations mentioned above. [. . . ] The Buyer must let Deville every opportunity of noticing any of those defects and irregularities in order to salve then. The Buyer must also keep the non standard supplies at the disposal of Deville, according to the instructions of the latter. EXTEND The warranty of Deville covers, except for any compensation or for damages, the free replacement or repairing of supplier the part acknowledged as being defected (except for wear and tear parts ) by its services to the exclusion of the fees for the workplace, for the removal and for the shipping. on enamelled equipments , appliances , crackles are never considered as a manufacturing defect. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DEVILLE C07910-A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DEVILLE C07910-A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag