User manual DEVILLE C07925

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DEVILLE C07925. We hope that this DEVILLE C07925 user guide will be useful to you.

Lastmanuals help download the user guide DEVILLE C07925.


Mode d'emploi DEVILLE C07925
Download
Manual abstract: user guide DEVILLE C07925

Detailed instructions for use are in the User's Guide.

[. . . ] 2 Characteristics and size of the smoke flue to which the appliance must be connected 5. 5 ­ Ventilation of the area in which the appliance is to be installed 5. 2 Building in dimensions ­ Protection of walls and casings made of combustible materials or which are affected by heat ­ Convection system 5. 2 - Installation in an existing fireplace built with refractory materials and initially made to be an open hearth 5. [. . . ] Any air coming in will hamper the good running of the appliance. Make a seal on the whole circumferenceof the steel collar . - The end of the pipe mustn't go beyond the collar after the fitting with the nozzle of the appliance. NOTA : Once the fireplace is finished, the superficial temperature of the walls of the house against which the fireplace is put must not exceed 50° on accessible C parts (Fig. - If the space is big enough, insert the pipe in the noozle placing the hands between between the upper part of the appliance et the base of the collar . - If there is not space enough above the appliance to place there the hands, the insertion of the pipe can be done easily in putting first in this piece of pipe at about ten centimetres from its base a broach which will allow to seize the the pipe to insert it on the noozle passing the hand from the inside of the appliance. This broach can stay there without hampering the working of the appliance (Fig. NOTA : The connecting pipe and the collar will have to be made of stainless steel with a minimum thickness of 0, 4 mm . The sketches 18 and 19, given as example, represent 2 cases of common installations: - Fig. Possibility of hot air release through the head and the existing hood. The design, condition or sizes of the chimney do not allow to a hot air release through the chimney head. A wooden beam has then to be completely protected in that case. The appliance must be set up on a floor with a sufficient bearing capacity. If the existing construction does not comply with this prior requirement, appropriate measures must be taken to allow the floor to bear the appliance, such as setting up a load distribution plate. Fig 17 shows installation within a DEVILLE fireplace. The connection method shown is the most common one : Connection to a masonry flue connected to the ceiling by a special fixing device. Other possibilities exist : see DTU 24-2-2. A hot air outlet with a minimum section of 800 cm should be installed at the front or sides, at least 300 mm from the ceiling, to expel the heat and reduce the inside temperature of the structure. A hot-air release vent can also be installed in the room behing the fireplace or upstairs on the room above see paragraph hot-air distribution. 2 - Installation in an existing fireplace built with refractory materials and initially made to be an open hearth Lighten the heating body to make it easy its installation in the fireplace, to do so remove the polystyrene wedges holding the deflector, take of the deflector, the cast iron parts that are inside the appliance and the door (see paragraph 7. 2 ­ Setting up of the appliance Once the appliance installed in the fireplace, put back all the removed parts: to do so proceed in the reverse order of the dismounting. Door handle : it must be handled thanks to the cold hand. [. . . ] They get filled in all the more easily as their meshing is thin : choose a suitable frequency of cleaning. Check the efficiency of the latch of the door and if necessary make the following adjustments (Fig. TERMS AND CONDITIONS Apart from the legal warranty, particularly for latent defects, Deville guarantees to deliver the furniture in case of obvious defects or non-conformity to the ordered furniture. Without prejudice to the provisions that are to be taken concerning the carrier, claims on delivery of furniture concerning the obvious defects or the non conformity, must be issued by the Buyer in writing a registered letter with confirmation of receipt to Deville company with in 5 days after noticing the defect. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DEVILLE C07925

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DEVILLE C07925 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag