User manual DHI MFC CONTROL BOX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DHI MFC CONTROL BOX. We hope that this DHI MFC CONTROL BOX user guide will be useful to you.

Lastmanuals help download the user guide DHI MFC CONTROL BOX.


Mode d'emploi DHI MFC CONTROL BOX
Download
Manual abstract: user guide DHI MFC CONTROL BOX

Detailed instructions for use are in the User's Guide.

[. . . ] Operation and Maintenance Manual MFC Control Box MFC-CBTM © 2011 Fluke Calibration © 2011 Fluke Calibration All rights reserved. Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Fluke Calibration, 4765 East Beautiful Lane, Phoenix, Arizona 85044-5318 USA. Fluke Calibration makes sincere efforts to ensure the accuracy and quality of its published materials; however, no warranty, expressed or implied, is provided. [. . . ] It also displays the MFC-CB factory serial number. OPERATION To access the ID function press [SPECIAL], <5prefs>, <4ID>. Select <1view>, to view the current ID. When the edit screen is opened, the cursor is on the first character. Numerical values can be entered directly from the keypad. In addition, the [] and [] keys can be used to toggle through a list of available alpha numeric characters. Holding the key slews through the characters. Character order going up ([]) is: blank space, symbols, lower case letters, upper case letters, numbers. Press [ENTER] to select a character and move to the next character. Page 35 © 2011 Fluke Calibration MFC-CBTM OPERATION AND MAINTENANCE MANUAL When a character is selected the cursor moves to the next character. To leave a blank character, press [ENTER] with the field for that character blank. Use this for the trailing characters if the ID being entered is less than twelve characters. After the last of the twelve characters has been entered, the <Save ID?> option is offered. Select <1no> to return to the ID edit screen. Select <2yes> to save the edited ID. Note · The ID can also be set remotely from a computer which is more convenient than entering characters one at a time from the keypad (see Section 4. 3. 4. 2, "ID(=)" command). The ID cannot be cleared or reset by any RESET function (see Section 3. 4. 1). · 3. 4. 4 <4cal> PURPOSE To view and edit MFC-CB electrical signal calibration coefficients and calibration date. The MFC-CB CALIBRATION function is considered part of MFC-CB maintenance and is therefore covered in the Maintenance, Adjustments and Calibration Section of this manual (see Section 5). 3. 4. 5 <5remote> PURPOSE To configure the MFC-CB COM1, COM2 and IEEE-488 communication ports. PRINCIPLE The MFC-CB has two RS232 communications ports referred to as COM1 and COM2 and a single IEEE-488 port. COM1 and the IEEE-488 port are for communicating with a host computer (see Section 3. 4. 5). COM2 is reserved for communicating with an external device (e. g. , a multimeter, molbox, second MFC-CB, etc. ). All the communication ports can be set up from the MFC-CB front panel. MFC-CB provides a self-test for its RS232 communication ports. The self-test allows verification that the MFC-CB RS232 ports (COM1 and COM2) are operating properly and that a valid interface cable is being used. [. . . ] A surrogate gas is often used in calibration and testing when the process gas cannot be used for safety or cost reasons. Level of security that can be set to prevent access to certain MFC-CB functions. A (adder) Clean DEV1&2 DEVICE 1, DEVICE 2 Device Channel Dif (Difference) FS K Factor M (multiplier) MFC MFC Profile MFM Ratio Set point Sum Surrogate Gas User Level © 2011 Fluke Calibration Page 80 7. APPENDIX 7. 5 Limited Warranty and Limitation of Liability Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DHI MFC CONTROL BOX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DHI MFC CONTROL BOX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag