User manual DHI OIL INTENSIFIER SYSTEM FOR OPG1 AND PG7302

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DHI OIL INTENSIFIER SYSTEM FOR OPG1 AND PG7302. We hope that this DHI OIL INTENSIFIER SYSTEM FOR OPG1 AND PG7302 user guide will be useful to you.

Lastmanuals help download the user guide DHI OIL INTENSIFIER SYSTEM FOR OPG1 AND PG7302.


Mode d'emploi DHI OIL INTENSIFIER SYSTEM FOR OPG1 AND PG7302
Download
Manual abstract: user guide DHI OIL INTENSIFIER SYSTEM FOR OPG1 AND PG7302

Detailed instructions for use are in the User's Guide.

[. . . ] Oil Intensifier System for OPG1 and PG7302 P/N 401746 Instruction Sheet 1. 3. SUPPLY connection to OPG1 TEST Port (DH500) TEST connection to PG7302 (DH500) Intensifier 4. [. . . ] In this condition the OPG1 pressure is shut off from the PG7302 and is applied to the low side of the intensifier. Increasing pressure on the low side of the intensifier results in pressure changes five times greater on the high side (PG7302 side) of the intensifier. Use the OPG1 to generate and adjust pressure as necessary to set test points and float the PG7302 piston. Before switching out the intensifier, be sure that the PG7302 piston is fully down (LSTOP) as the pressure may change abruptly during the switching procedure. If possible, switch out the intensifier at the same INSTALLATION Position the OIS between the OPG1 and the PG7302 with the OPG1 to the right and the PG7302 to the left. Using a DH500 coned and threaded tube, connect the OPG1 lateral TEST port to the OIS's SUPPLY port (1). Using a DH500 coned and threaded tube or two tubes and a tee, connect the PG302 TEST port to the OIS's lateral TEST port (2). Operation: Intensifier Not In Use (Pressure < 200 MPa (30 000 psi)) Open LOW PRESSURE SHUTOFF valve (4) and close INTENSIFIER SHUTOFF valve (5). In this condition, OPG1 generates pressure straight through the Intensifier System, bypassing the intensifier. Plug TEST port (6) if it is not being used. pressure as it was switched in so that its pistons are back to the start position. To switch out the intensifier, first close the INTENSIFIER SHUTOFF valve (5) and then open the LOW PRESSURE SHUTOFF valve (4). Load the entire mass set on the PG7302. Close the INTENSIFIER SHUTOFF valve (5). Open the LOW PRESSURE SHUTOFF valve (4). [. . . ] It is only necessary to use this procedure if the intensifier pistons have become positioned near the end of stroke and cannot be returned naturally by the high pressure. OPG1 and PG7302 are trademarks, registered and otherwise, of DH Instruments, Inc. Document 560035c 031103 DH Instruments, Inc. 4765 East Beautiful Lane Phoenix AZ 85044-5318 USA Tel 602. 431. 9100 Fax 602. 431. 9559 dhi@dhinstruments. com www. dhinstruments. com [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DHI OIL INTENSIFIER SYSTEM FOR OPG1 AND PG7302

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DHI OIL INTENSIFIER SYSTEM FOR OPG1 AND PG7302 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag