User manual DIGITECH SDISC SYSEX1.25

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DIGITECH SDISC SYSEX1.25. We hope that this DIGITECH SDISC SYSEX1.25 user guide will be useful to you.

Lastmanuals help download the user guide DIGITECH SDISC SYSEX1.25.


Mode d'emploi DIGITECH SDISC SYSEX1.25
Download
Manual abstract: user guide DIGITECH SDISC SYSEX1.25

Detailed instructions for use are in the User's Guide.

[. . . ] 5 Request Configuration Address - 00(h) . 5 Receive Configuration Address - 41(h) . 11 Request Algorithm Link Table - 52(h) . 12 Respond Algorithm Link Table - 53(h) . [. . . ] RESET DEVICE (21h) SYS_HEAD, 21(h), F7(h) The Reset Device procedure causes the DigiTech device to reboot the software as if the power had been turned off and then back on. If edits have been made to the current program without saving, they will be lost. bb DigiTech S-DISCTM SysEx 7 Procedures RESET FACTORY SETTINGS (22h) SYS_HEAD, 22(h), rr, xx, F7(h) When rr = 00(h) the factory programs are reloaded. When rr = 01(h) the factory software defaults are reloaded. When rr = 02(h) both programs and software are reloaded. xx Reserved for future use. The Reset Factory Settings procedure causes the DigiTech device to reload a sections of the EPROM factory defaults. REQUEST ALGORITHM (31h) SYS_HEAD, 31(h), aa, F7(h) aa Algorithms numbers 1 through 128 (00-7F(h)) where 1 through 64 are user algorithms and 65 through 128 are factory algorithms. When a Request Algorithm procedure is received, then DigiTech device will respond with a Receive Algorithm procedure. RECEIVE ALGORITHM (30h) SYS_HEAD, 30(h), aa, dd(1st)1 dd(1st)2, . . . dd(nth)1, dd(nth)2, F7(h) Algorithms numbers 1 through 128 (00-7F(h)) where 1 through 64 are user algorithms and 65 through 128 are factory algorithms. dd(n)1 0000000v(b) where v is bit 7 of the nth byte of the received program. dd(n)2 0vvvvvvv(b) where v is bits 6 through 0 of the nth byte of the received program. The Receive Algorithm procedure is used to load an algorithm into the DigiTech device that has the ability to implement user defined Algorithms. The number of algorithm bytes to be received (n) is different for each algorithm. Note: if a Receive Algorithm procedure is received as a result of a Request Algorithm procedure, byte (aa) may not match the requested algorithm number. This is due to a small bug that was left undetected. This causes no problems since the device receiving the algorithm will place the algorithm in the requested user algorithm slot or in the next available slot if the number is already used. aa 8 DigiTech S-DISCTM SysEx Procedures REQUEST BULK DUMP (49h) SYS_HEAD, 49(h), F7(h) When a Request Bulk Dump procedure is received, the DigiTech device will respond with one or more Receive Large RAM Area procedures. RECEIVE LARGE RAM AREA (48h) SYS_HEAD, 48(h), bb, ww, xx, yy, z, z nn1, nn2, nn3, dd(1st)1, dd(1st)2, . . . dd(cth)1, dd(cth)2, F7(h) Bank number of RAM being received. Currently the bank normally used in these DigiTech devices is 00h. ww 0000000v(b) where v is bit 15 of the RAM address. xx 0vvvvvvv(b) where v is bits 14 - 8 of the RAM address. [. . . ] The number of the Module's output to which the xth Module's wth input is connected (00 indicates that it is not connected). bb cc dd vv(x) ii(x) oo(x) pp(x)(w) nn(x)(w) The Respond Module Link Table procedure is sent in response to the Request Module Link Table procedure. This is a reference table for an algorithm's module linking and is ignored if sent to a DigiTech product. 12 DigiTech S-DISCTM SysEx Procedures REQUEST PARAMETER VALUE (17h) NOTE: This procedure is only implemented in the GSP-2101 Version 3. xx software. SYS_HEAD, 17(h), mm1, mm2, pp1, pp2, F7(h) mm pp The effect module's position in the Algorithm The Paramter's position in the effect module. When a Request Parameter Value procedure is received, the device will respond with a Receive Parameter Value procedure. RECEIVE PARAMETER VALUE (18h) NOTE: This procedure is only implemented in the GSP-2101 Version 3. xx software. SYS_HEAD, 18(h), mm1, mm2, pp1, pp2, vv1, vv2, F7(h) mm pp vv The effect module's position in the Algorithm The Paramter's position in the effect module. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DIGITECH SDISC SYSEX1.25

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DIGITECH SDISC SYSEX1.25 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag