User manual DOT HILL 2732 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DOT HILL 2732. We hope that this DOT HILL 2732 user guide will be useful to you.

Lastmanuals help download the user guide DOT HILL 2732.


Mode d'emploi DOT HILL 2732
Download
Manual abstract: user guide DOT HILL 2732DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] 2732 · · · · · · · · · S P E C I F I C AT I O N S H E E T Premium performance for high IO applications connected with fibre Built in Redundancy · RAID 0, 1, 3, 5, 6, 10, 50 · Redundant, hot swap components · AssuredSnapTM - Snapshot capability · AssuredCopyTM - Additional data protection with full volume copies · Built-in schedule capability Scalability and Performance · Dual or single RAID controller or JBOD · Data rates up to 4Gb/sec. Fibre Channel · 1. 7TB base capacity that scales to 192TB (utilizing 2TB SATA drives) · OS Support - Windows, Linux, SuSE, Solaris Easy Set-up and Management · Unified LUN architecture streamlines configuration · RAIDar 2. 0 full featured management interface Environmentally Responsible / Lower TCO · EcoStorTM - Economically and environmentally sound technologies - SimulCacheTM - Low latency cache mirroring - Battery-free cache backup - DC power option - 2 terabyte energy saving drives · RoHS-5 and WEEE compliant · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · The 2732 from Dot Hill Systems ser ves the Fibre Channel SAN market allowing customers to easily create their own high-speed storage area networks. The Dot Hill 2732 storage systems are used for vir tualized storage, file systems, Share Point, MS Exchange, MS SQL, just to name a few applications. [. . . ] Then it makes sense to add data protection options - AssuredSnapTM and AssuredCopyTM. AssuredSnapTM provides the 2732 storage array with volume snapshot capability allowing point-in-time copies that can be used to maximize business continuity. AssuredCopyTM creates a full volume copy which protects against disk failures and provides full archive ability. Dot Hill's `set and forget' scheduler capability gives storage administrators peace of mind. Make sure you have the backups that enable quick point-in-time recovery. Revolutionary connectivity, availability, quality and value The 2732 uses patented SimulCacheTM technology that instantly and simultaneously mirrors cache between RAID controllers, leading to significant performance improvements over traditional implementations. Eco-friendly EcoStor TM The 2732 uses super capacitors instead of RAID cache batteries, providing infinite cache backup during a power loss while being environmentally friendly. Using super capacitors eliminates the need for battery maintenance, reducing the total cost of ownership. Easy Management Tool with W izards Dot Hill's 2732 storage systems are easy to configure and manage with improved RAIDar 2. 0, the intuitive Web Based Interface (WBI) which provides storage setup and monitoring without the need for host based software. RAIDar 2. 0 contains installation and configuration wizards to make management easy. · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ª · 2732 FC spec 2732 Specifications GENERAL ································································ DECLARED ACOUSTIC NOISE LEVELS . . . . . . . . . . . . . . . . . . . . . . . . Sound Power Sound Pressure <6. 03B Sound Power <55dBA Sound Pressure Product Family Product Type Chassis Configuration Disk Architecture Max Drives per Chassis Total Capacity Total Disks Mounting Options Max Number of Chassis Max Capacity per Chassis Data Management Services (DMS) 2002 Series RAID, JBOD 2U 3Gb SAS/3Gb SATA-II 12 drives 2TB/192TB (with expansion trays) 96 19" Rack, Telco Rack, Rack tray 8 (1 RAID and 7 JBOD) 24TB (2TB SATA-II drives) AssuredSnapTM, AssuredCopyTM SHOCK AND VIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shock, Operational Shock, Non-Operational Vibration, Operational Vibration, Non-Operational (1hr) 5. 0G, 10ms, half sine 15G 11ms, half sine 0. 21Grms Random 5Hz to 500Hz flat spectrum/feed forward X & Y axes - 0. 85 Grms 3Hz - 365 Hz Z axis - 1. 2 Grms 3Hz - 365H PROTOCOLS AND STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ICMP (RFC 792, 950, 1256) IP (RFC, 894, 1092) TCP (RFC 793) SCSI-2 and SCSI-3 Up to 4 direct connected hosts, 2 or 4Gb Fibre Channel FCP 2/4 Dual Controller HIGH-AVAILABILITY FEATURES Redundant Hot-Swap Controllers Redundant Hot-Swap Disk Redundant Hot-Swap Fans Redundant Hot-Swap Power Dual Power Cords Hot Standby Spare Automatic Failover Multi-Path Support Snapshot w/AssuredSnap Volume Copy with AssuredCopy Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes ··································· HOSTS Supported Hosts Interface Type External Ports ··································································· DRIVES ··································································· Max Number of Drives 3. 5" Drive Options 96 SAS 146GB 15K RPM SAS 300GB 15K RPM SAS 450GB 15K RPM SATA-II 500GB 7200 RPM SATA-II 750GB 7200 RPM SATA-II 1TB 7200 RPM SATA-II 2TB 5400 RPM 32, 80GB SSD Non-RAID, 0, 1, 3, 5, 6, 10, and 50 Hardware 1GB per controller Battery-free protection with super capacitors 32 128 256 Yes - SimulCacheTM Yes Yes - Non-volatile REGULATORY Safety ··························································· UL 60950-1:2003 (USA) CAN/CSA-C22. 2 No. 60950-1-03 (Canada) EN 60950-1 :2001 + A11 (EU) IEC 60950-1 :2001 (International) CFR 47 Part 15 Subpart B (U. S. A. Class A) ICES-003:2004 Class A EN55022:2006 + A1:2007 Class A EN51000-3-2 2006 (Harmonics) EN61000-3-3 1995 (Amended by A1:2001 and A2:2005) (Flicker) EN55024 1998 (Amended by A1:2001 and A2:2003) (EU, Immunity) RoHS-5 Compliance , China RoHS, WEEE United States, European Union (EU), Australia/New Zealand, Canada, Germany (GSMark), Japan, China (PRC) RAID ······································································ Electromagnetic Compatibility Levels Supported RAID Type Cache Memory Cache Backup Virtual disks per System Volumes per virtual disk Volumes per System Mirrored Cache Super Capacitor Cache Backup Cache Backup to Flash RoHS and WEEE Country Approvals MANAGEMENT ························································· Interface Types Protocols Supported Management Consoles Management Software Mini DB9 RS232, 10/100 Ethernet SNMP, SSL, SSH, SMTP WEB GUI, CLI RAIDar 2. 0 ···································· SUPPORT ······························································· · POWER REQUIREMENTS - AC Input Power Requirements Max Input Power Heat Dissipation Voltage Max Input Power Heat Dissipation 100­240VAC, 50/60 Hz, 4. 5-1. 9A 475W maximum continuous 1622 BTU/hour ···································· POWER REQUIREMENTS - DC -39 to -72VDC, -48/-60V nominal 500W maximum continuous 1706 BTU/hour Software Warranty Standard Hardware Warranty Environmental Monitoring Phone-home Capability Remote Diagnostics Non-disruptive Updates Non-disruptive Volume Expansion 90 days 3 years SNMP, CLI, RAIDar, SMTP Yes Yes Yes Yes for primary volumes and snapshot volumes TEMPERATURE AND HUMIDITY RANGES . . . . . . . . . . . . . . . . . . . Operating Temperature Shipping Temperature 41°F to 104°F (5°C to 40°C) -40°F to 158°F (-40°C to 70°C) Note: Derate 2°C for every km, up to 3000 meters 10% to 90% RH @ 104°F (40°C), non-condensing Up to 93% RH @ 104°F (40°C) non-condensing PHYSICAL ······························································· Operating Humidity Non-Operating Humidity Height Depth (excluding cables) Width Chassis Weight Chassis (w/250GB drives) Weight 3. 5 Inches / 8. 9cm 23. 7 Inches / 60. 2cm 17. 6 Inches / 44. 7cm 44lbs. [. . . ] Dot Hill reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. No part of this document may be copied or reproduced without written permission of Dot Hill Systems Corp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOT HILL 2732

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DOT HILL 2732 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag