User manual DSC PC 1550 V 4.0

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DSC PC 1550. We hope that this DSC PC 1550 user guide will be useful to you.

Lastmanuals help download the user guide DSC PC 1550.


Mode d'emploi DSC PC 1550
Download
Manual abstract: user guide DSC PC 1550V 4.0

Detailed instructions for use are in the User's Guide.

[. . . ] TABLE OF CONTENTS FEATURES SPECIFICATIONS 2 2 [01] 1st Phone Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 [02] 1st Account Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 [03] 2nd Phone Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 [04] 2nd Account Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The closing code transmission takes place after the exit delay time. Therefore, if the system is armed and disarmed before the expiry of the exit time, no closing transmission will take place. The partial closing code, if used, is transmitted in tandem with the regular closing code to identify the closing as a partial closing. When the system has been armed using the Quick-Arm command [ ][0] or using the Auto-Arm feature, access code #1 will be transmitted. * [08] Opening (Disarming) Reporting Codes After Alarm Reporting Code 3/1 FORMAT - Non-extended reporting requires: · 3-digit account code in sections [02] or [04]. Enter 1230 for account code 123 · Format Code [0], [1], [2], [3], [4] depending on receiver type in section [23]. · Single line digit Alarm Reporting Code Section [05] i. e. Enter [30] for single digit code 3 (0 = no pulses) TRANSMISSION SENT: 123 3 The first 6 reporting codes correspond to the 6 user access codes. When the system is disarmed using one of the access codes, the corresponding reporting code in this section is transmitted. See section [07] above for examples of reporting code programming. If the After Alarm Code is programmed, that code will be transmitted to the monitoring station on opening if an alarm occurred during previous armed period. This feature is useful for installations where openings and closings are not reported normally, but it is desired to have a report to the monitoring station on opening if an alarm did occur during the previous armed period. This feature allows the monitoring station to know when the user is on the premises and available to receive a report about alarms while the system was closed. 4/2 FORMAT - Non-extended reporting requires: · 4-digit account code in sections [02] or [04]. Enter 1234 for account code 1234 · Format Code [0], [1], [2], [3], [4] depending on receiver type in section [23]. · 2-digit Alarm Reporting Code in section [05] i. e. Enter [31] for 2-digit code 31 TRANSMISSION SENT: 1234 31 [09] Priority Alarms and Restorals 3/1 FORMAT - Extended reporting requires: · 3-digit Account Code in section [02] or [04] i. e. Enter 1230 for code 123 These reporting codes are used by the communicator to transmit the following list of troubles, alarms and restorals. See section [05] as a guide for programming. · Keypad [A]uxiliary restore. 9 Transmission for operation of the [F], [A] and [P] keys will only take place if the appropriate sections in [09] are programmed with a reporting code. [10] Maintenance Alarms and Restorals These reporting codes are used by the communicator to transmit the following list of alarms and restorals. See section [05] as a guide to programming. · Automatic Test Code Test code is not transmitted if periodic downloading is selected, section [14], light 3. For Automatic Test Code Reporting, the time between reports (in days) must be entered in section [17] and the time of day for the report must be entered in section [19]. [11] Zone Definitions As in the reporting codes sections, once this section is entered, 6 2-digit numbers are required. Each 2-digit number entered defines how a zone will operate. Zone Definitions Digit #1 The first digit determines whether the zone will cause a silent alarm or an audible alarm and whether the zone response will be fast or slow. [. . . ] Anyone returning goods to Digital Security Controls Ltd. must first obtain an authorization number. will not accept any shipment whatsoever for which prior authorization has not been obtained. Conditions to Void Warranty This warranty applies only to defects in parts and workmanship relating to normal use. It does not cover: · damage incurred in shipping or handling; · damage caused by disaster such as fire, flood, wind, earthquake or lightning; · damage due to causes beyond the control of Digital Security Controls Ltd. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC PC 1550

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DSC PC 1550 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag