User manual DSC PC1616

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DSC PC1616. We hope that this DSC PC1616 user guide will be useful to you.

Lastmanuals help download the user guide DSC PC1616.


Mode d'emploi DSC PC1616
Download
Manual abstract: user guide DSC PC1616

Detailed instructions for use are in the User's Guide.

[. . . ] WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. PC1616/PC1832/PC1864 User Manual FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer-ence in a residential installation. [. . . ] NOTE: Duress codes cannot be programmed as a duplicate or as a "Code + 1". User Code Attributes 1. The default attributes of a new code will be the attributes of the code used to enter whether it is a new code or an existing code being programmed. System Master (Code 40) has Partition Access for all partitions, as well as Attributes 3-4 ON by default. NOTE: These attributes are not changeable. Inherent Attributes (all codes except installer and maintenance) Arm / Disarm - Any Access Code with Partition Access enabled will be valid for arming and disarming that partition. Command Outputs ([, ][7][1], [, ][7][2], [, ][7][3], and [, ][7][4]) - If these outputs require Access Code entry, any Access Code with Partition Access will be valid for performing the [, ][7][1-4][Access Code] functions on that partition. Programmable Attributes ([, ][5][Master/Supervisor Code][9][Code]) 1. 8. For Future Use For Future Use Zone Bypassing Enabled ESCORT Access Downlook Remote Trigger to Phone Number 1 Downlook Remote Trigger to Phone Number 2 Bell Squawk upon Arming/Disarming One Time Use Code NOTE: Attributes 5 and 6 cannot be enabled on the same access code. 12 Bell Squawk Attribute This attribute is used to determine whether an access code should generate an arming/disarming Bell Squawk upon entry of the code for Away arming. The Wireless Keys with access codes associated with them may generate Arming/Disarming Bell squawks. If desired, this option may be used with codes that are manually entered. Please contact your installer to have this programmed. NOTE: The Master Code cannot use the Bell Squawk attribute, but is required to enable it for other codes. NOTE: This feature cannot prevent the Arm/Disarming squawks from being generated if an access code assigned to a WLS Key is manually entered at a keypad. Partition Assignment Mask In order to accommodate Access Code Partition Assignment for the multiple partitions found on this product the user must enter [, ][5][Master Code][8][Code number to be change] (ex. Under this section, each bit represents the corresponding partition's access (i. e. The Master Code has access to all partitions, and cannot be modified. Partition Assignment Mask ([, ][5][Master/Supervisor Code][8][Code]) 1. Partition Eight Access Notes on Access Codes and Programming 1. There will still be 37 codes if option selected for 6-digit access codes. - [, ][5][MASTER CODE] [01 to 32, 33, 34, 40, 41, 42] to program access codes - [, ][5][MASTER CODE][8] enters the Partition Assignment Mode [01 to 32, 33, 34, 41, 42] to edit access code partition assignments - [, ][5][MASTER CODE][9] Enters the Attribute Mode [01 to 32, 33, 34, 41, 42] to edit access code Attributes. The Master Code's attributes cannot be changed. When a new code is programmed in it will be checked against all other codes in the system. If a duplicate code is found, an error tone is given and the code is returned to what it was before it was changed. This applies to both 4 and 6-digit codes. Erasing an Access Code To erase a code, select the code and enter as the first digit. [. . . ] Every installation should be evaluated by a security professional to ensure that all access points and areas are covered. Locks and latches on windows and doors must be secure and operate as intended. Windows, doors, walls, ceilings and other building materials must be of sufficient strength and construction to provide the level of protection expected. A reevaluation must be done during and after any construction activity. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC PC1616

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DSC PC1616 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag