User manual DSC PC2550

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DSC PC2550. We hope that this DSC PC2550 user guide will be useful to you.

Lastmanuals help download the user guide DSC PC2550.


Mode d'emploi DSC PC2550
Download
Manual abstract: user guide DSC PC2550

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL PC255O Canadian Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. [. . . ] Refer to zone chart on keypad door for zone information. Fire light is ON when a detector on the fire loop is in alarm. Press any key within 30 seconds of first alarm to get 2 minutes to reset smoke detectors. Ready light ON: system ready for arming. Ready light OFF: open zone; must be closed or bypassed before arming. Ready, Armed and Program lights flashing indicates user code 9-16 programming. Armed light will come ON indicating system armed. Ensure "Ready" light is ON, enter [4 digit] access code to arm panel. Armed, Ready and Program lights flashing indicates user code 9-16 programming. Memory light ON means an alarm has occurred. To display zone that caused alarm, press [ ] then [3]. Zone light will come on indicating which zone caused the alarm. Bypass light comes ON when you bypass a zone. To bypass a zone, press [ ], [1], [Access Code] and then the zone(s) you wish to Bypass. Trouble light ON means there is a fault on the system. Press any key to silence keypad beeping. Press [ ] then [2] to display type of trouble. Zone Light Trouble PRESS [F] for 2 seconds to activate FIRE transmission. PRESS [A] for 2 seconds to activate an AUXILIARY transmission. PRESS [P] for 2 seconds to activate PANIC transmission. THESE BUTTONS WILL NOT FUNCTION UNLESS PROGRAMMED BY INSTALLER. COLORED LABELS ON KEYPAD DOOR INDICATE WHICH KEYS ARE ACTIVE. 1 . . . . . . . . . . . . . . . Smoke detector circuit 8 . . . . . . . . . . . . . . . Clock needs resetting Program light flashes when programming user codes 1 to 8. Select a code by pressing a key from 1 to 8 and enter the [4 digit] code. [. . . ] Arm then disarm the panel to silence the signal. Repeat this test by pressing the [A] key and the [P] key in turn. Remember, the [A] key does not ring the bell and the [P] key may not be programmed for an audible signal. If the fire zone is used, activation will cause the signal to sound in a pulsed mode. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC PC2550

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DSC PC2550 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag